Uncertainty budget in the cross-calibration between SNLS and the HST via the observation of Landolt secondary standards.

uM gM rM iMa zM

Aperture corrections ± 0.0045 ± 0.0023 ± 0.0014 <0.001 ± 0.0036
Flat-field error ± 0.0012 <0.001 <0.001 <0.001 <0.001
Landolt uniformity ± 0.0040 ± 0.0020 ± 0.0020 ± 0.0020 ± 0.0040
Shutter precision ± 0.0015 ± 0.0015 ± 0.0015 ± 0.0015 ± 0.0015
Background residuals ± 0.0010 ± 0.0010 ± 0.0010 ± 0.0010 ± 0.0010
BD +17 4708 landolt measurements ± 0.0034 ± 0.0027 ± 0.0028 ± 0.0028 ± 0.0030
Landolt to MegaCam transformation ± 0.0228 ± 0.0023 ± 0.0043 ± 0.0026 ± 0.0178

Total ± 0.0239 ± 0.0050 ± 0.0060 ± 0.0047 ± 0.0189

Notes.

(a)

The i2M band can be calibrated relatively to iM with a precision of 2 mmag (cf. Sect. 5.1).