Table 5
Uncertainty budget in the cross-calibration between SNLS and the HST via the observation of Landolt secondary standards.
uM | gM | rM | iMa | zM | |
|
|||||
Aperture corrections | ± 0.0045 | ± 0.0023 | ± 0.0014 | <0.001 | ± 0.0036 |
Flat-field error | ± 0.0012 | <0.001 | <0.001 | <0.001 | <0.001 |
Landolt uniformity | ± 0.0040 | ± 0.0020 | ± 0.0020 | ± 0.0020 | ± 0.0040 |
Shutter precision | ± 0.0015 | ± 0.0015 | ± 0.0015 | ± 0.0015 | ± 0.0015 |
Background residuals | ± 0.0010 | ± 0.0010 | ± 0.0010 | ± 0.0010 | ± 0.0010 |
BD +17 4708 landolt measurements | ± 0.0034 | ± 0.0027 | ± 0.0028 | ± 0.0028 | ± 0.0030 |
Landolt to MegaCam transformation | ± 0.0228 | ± 0.0023 | ± 0.0043 | ± 0.0026 | ± 0.0178 |
|
|||||
Total | ± 0.0239 | ± 0.0050 | ± 0.0060 | ± 0.0047 | ± 0.0189 |
Notes.
(a)
The i2M band can be calibrated relatively to iM with a precision of 2 mmag (cf. Sect. 5.1).