Table 3
Observed near-IR to sub-millimetre fluxes for AFGL 2591, collated from the literature.
Wavelength | Flux density | Aperture | Description / Origin | ||
(μm) | (Jy) | radius | |||
|
|||||
1.235 | 0.11 ± 10% | Irregular, <40′′ | 2MASS J band (1)a | ||
1.662 | 0.43 ± 10% | Irregular, <40′′ | 2MASS H band (1)a | ||
2.159 | 2.30 ± 10% | Irregular, <40′′ | 2MASS Ks band (1)a | ||
3.500 | 33.68 ± 1.347 | ISO apertures | Sampled ISO-SWS spectrum (2) | ||
3.822 | 68.98 ± 2.759 | ISO apertures | Sampled ISO-SWS spectrum (2) | ||
4.174 | 108.4 ± 7.590 | ISO apertures | Sampled ISO-SWS spectrum (2) | ||
4.558 | 127.2 ± 8.906 | ISO apertures | Sampled ISO-SWS spectrum (2) | ||
4.978 | 186.8 ± 13.08 | ISO apertures | Sampled ISO-SWS spectrum (2) | ||
5.436 | 233.8 ± 16.37 | ISO apertures | Sampled ISO-SWS spectrum (2) | ||
5.937 | 245.0 ± 17.15 | ISO apertures | Sampled ISO-SWS spectrum (2) | ||
6.483 | 273.7 ± 19.16 | ISO apertures | Sampled ISO-SWS spectrum (2) | ||
7.080 | 353.2 ± 24.73 | ISO apertures | Sampled ISO-SWS spectrum (2) | ||
7.732 | 406.2 ± 28.43 | ISO apertures | Sampled ISO-SWS spectrum (2) | ||
8.444 | 221.6 ± 15.51 | ISO apertures | Sampled ISO-SWS spectrum (2) | ||
9.221 | 78.69 ± 5.508 | ISO apertures | Sampled ISO-SWS spectrum (2) | ||
10.070 | 75.49 ± 5.285 | ISO apertures | Sampled ISO-SWS spectrum (2) | ||
10.997 | 154.3 ± 10.80 | ISO apertures | Sampled ISO-SWS spectrum (2) | ||
12.009 | 416.8 ± 50.01 | ISO apertures | Sampled ISO-SWS spectrum (2) | ||
13.115 | 583.4 ± 70.01 | ISO apertures | Sampled ISO-SWS spectrum (2) | ||
14.322 | 600.0 ± 72.00 | ISO apertures | Sampled ISO-SWS spectrum (2) | ||
15.641 | 556.8 ± 66.81 | ISO apertures | Sampled ISO-SWS spectrum (2) | ||
17.081 | 503.2 ± 50.32 | ISO apertures | Sampled ISO-SWS spectrum (2) | ||
18.653 | 542.3 ± 54.23 | ISO apertures | Sampled ISO-SWS spectrum (2) | ||
20.370 | 717.7 ± 93.31 | ISO apertures | Sampled ISO-SWS spectrum (2) | ||
22.245 | 886.1 ± 115.2 | ISO apertures | Sampled ISO-SWS spectrum (2) | ||
24.293 | 1118 ± 145.3 | ISO apertures | Sampled ISO-SWS spectrum (2) | ||
26.530 | 1391 ± 180.9 | ISO apertures | Sampled ISO-SWS spectrum (2) | ||
28.972 | 1728 ± 293.8 | ISO apertures | Sampled ISO-SWS spectrum (2) | ||
31.639 | 2118 ± 465.9 | ISO apertures | Sampled ISO-SWS spectrum (2) | ||
34.552 | 2413 ± 530.9 | ISO apertures | Sampled ISO-SWS spectrum (2) | ||
37.733 | 2810 ± 618.3 | ISO apertures | Sampled ISO-SWS spectrum (2) | ||
41.207 | 3384 ± 744.5 | ISO apertures | Sampled ISO-SWS spectrum (2) | ||
45.000 | 3879 ± 853.5 | ISO apertures | Sampled ISO-SWS spectrum (2) | ||
60 | 4830 ± 290 | 6′ | IRAS 60 μm (3)b | ||
100 | 4390 ± 290 | 6′ | IRAS 100 μm (3)b | ||
350 | 440 ± 20% | 60′′ | CSO (4) | ||
450 | 107 ± 50% | 60′′ | JCMT (5)c | ||
850 | 15 ± 20% | 72′′ | JCMT (5)c |
Notes.
Image shown in Fig. 2. Fluxes found by irregular aperture photometry.
References. (given in parentheses in the column Description/Origin): (1) Skrutskie et al. (2006); (2) Sloan et al. (2003); (3) Miville-Deschênes & Lagache (2005); (4) Mueller et al. (2002a); (5) Di Francesco et al. (2008).
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.