Table 1
Specifications of all detected bursts detected during the long low state (# 1−12) and 2 bursts that have the smallest hard color value in the RXTE archive (# A, B; see Fig. 4).
Id. | Instr. | Date | Time | MJD | RXTE OBSID | PCUs | SC | HC | Fluence | Decay | Pers. flux4 | EED5 | |
(10-7 erg cm-2) | time3 | (10-9 erg | (s) | ||||||||||
(UT) | meas.1 | extrap.2 | (s) | cm-2s-1) | |||||||||
|
|||||||||||||
1 | PCA | Apr. 27, 2009 | 19:42:36 | 54 948.82125 | 94090-01-01-02 | 2 | 1.92 | 1.08 | 3.2(2) | 4.1 | 3.3(2) | 4.01(3) | 0.70 |
2 | PCA | Apr. 29, 2009 | 16:52:04 | 54 950.70283 | 94090-01-01-05 | 1,2 | 1.96 | 1.14 | 3.3(2) | 4.3 | 3.4(1) | 3.93(3) | 0.90 |
3 | PCA | May 05, 2009 | 18:35:37 | 54 956.77474 | 94090-01-02-03 | 2,4 | 2.05 | 1.19 | 3.4(2) | 4.5 | 3.2(1) | 4.11(3) | 0.90 |
4 | PCA&BAT | May 07, 2009 | 17:45:34 | 54 958.73999 | 94090-01-02-02 | 2 | 2.04 | 1.20 | 3.4(2) | 4.3 | 3.4(2) | 4.04(3) | 1.30 |
5 | PCA | May 27, 2009 | 07:42:57 | 54 978.32149 | 94090-01-04-00 | 2 | 2.08 | 1.24 | 3.5(2) | 5.0 | 3.7(2) | 4.75(4) | 1.68 |
6 | PCA | May 27, 2009 | 11:52:39 | 54 978.49490 | 94090-01-04-01 | 2 | 2.03 | 1.25 | 3.6(2) | 5.2 | 3.6(2) | 4.81(4) | 1.55 |
7 | PCA | May 30, 2009 | 04:29:42 | 54 981.18730 | 94090-01-05-00 | 0,2,4 | 2.12 | 1.24 | 3.6(1) | 4.6 | 3.5(1) | 5.00(2) | 1.40 |
8 | BAT | May 31, 2009 | 21:38:16 | 54 982.90157 | |||||||||
9 | BAT | Jun. 06, 2009 | 09:28:19 | 54 988.39465 | |||||||||
10 | XRT&BAT | Jun. 06, 2009 | 12:43:37 | 54 988.53029 | |||||||||
11 | PCA | Jun. 12, 2009 | 12:49:14 | 54 994.53420 | 94090-02-01-00 | 2 | 1.92 | 1.12 | 3.2(2) | 4.2 | 3.1(2) | 6.73(4) | 0.59 |
12 | PCA | Jun. 12, 2009 | 14:42:45 | 54 994.61303 | 94090-02-01-00 | 1,2 | 1.95 | 1.09 | 3.2(1) | 3.6 | 3.5(1) | 6.73(4) | 0.41 |
|
|||||||||||||
A | PCA | Sep. 29, 2004 | 10:29:03 | 53 277.43685 | 90027-01-03-05 | 0,2,3,4 | 1.74 | 0.97 | 3.5(2) | 4.6 | 3.2(1) | 4.28(2) | 0.61 |
B | PCA | Mar. 06, 2011 | 18:32:11 | 55 626.77236 | 96090-01-01-020 | 1,2 | 1.74 | 0.92 | 2.4(2) | 2.9 | 2.7(2) | 4.90(2) | 0.10 |
Notes. Numbers between parentheses refer to the uncertainty in the last digits.
This is the fluence as measured under the exponential decay fitted to the time profile of the bolometric flux after the peak, plus the peak flux times the time interval between the peak flux and the start of the precursor;
this is the fluence as measured under the exponential decay of the bolometric flux, backwards extrapolated to the start of the precursor;
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.