Free Access

Table A.1

Available photometry.

Filter λ 0 mag σ mag flux σ flux Ref.
(μm) (mag) (mag) (Jy) (Jy)

Stromgren u 0.35 6.354 0.010 13.69 0.13 6
Johnson U 0.37 5.070 0.025 17.63 0.40 1
Stromgren v 0.41 5.203 0.009 40.49 0.34 6
Tycho B 0.42 5.015 0.014 38.89 0.50 3
Johnson B 0.44 4.790 0.019 53.87 0.94 1
Stromgren b 0.47 4.891 0.005 47.21 0.22 6
Tycho V 0.53 4.793 0.009 45.51 0.38 3
Johnson V 0.55 4.990 0.015 38.45 0.53 1
Stromgren y 0.55 4.779 0.003 45.40 0.13 6
Johnson R 0.70 4.887 0.023 33.40 0.71 1
Johnson I 0.90 4.581 0.025 35.74 0.82 1
2MASS J 1.25 4.382 0.26 28.92 6.93 2
2MASS H 1.65 4.251 0.212 22.24 4.34 2
2MASS Ks 2.15 4.298 0.031 12.82 0.37 2
WISE1 3.35 4.269 0.094 6.069 0.52 11
IRAC1 3.56 4.949 0.035 13
IRAC2 4.51 3.238 0.038 13
WISE2 4.60 3.775 0.059 5.309 0.29 11
IRAC3 5.76 2.214 0.007 13
IRAC4 7.96 1.458 0.004 13
AKARI9 9 1.451 0.017 10
WISE3 11.56 3.615 0.015 1.134 0.016 11
Si-5 11.7 1.155 0.002 8
WISE4 22.09 2.348 0.020 0.962 0.018 11
AKARI18 18 0.921 0.020 10
Qa 18.3 1.094 0.011 8
MIPS24 23.84 0.766 0.030 5
MIPS70 71.42 0.197 0.020 5
PACS70 70 0.191 0.005 7
PACS100 100 0.089 0.003 7
PACS160 160 0.036 0.002 7
LABOCA 870 0.040 0.01 9
SIMBA 1200  <0.026 0. 12

Notes. (1): Johnson et al. (1966); (2): 2MASS catalogue (Skrutskie et al. 2006); (3): Tycho-2 catalogue (Høg et al. 2000); (4) IRAS faint source catalogue; (5): Rebull et al. (2008); (6) Hauck & Mermilliod (1998); (7): present work; (8): Moerchen et al. (2010); (9): Nilsson et al. (2009), see text; (10): Ishihara et al. (2010); (11): WISE Preliminary Release Source Catalog. The WISE magnitude limits in the Explanatory Suplement indicate that the 3.4, 4.6 and 12 μm photometry of HD 172555 is saturated. However, the WISE pipeline performs PSF fitting when dealing with saturated sources and produces accurate results for bands 1, 3, and 4. Unfortunately, for band 2 at 4.6 μm the pipeline does not produce good results for saturated sources (Stapelfeldt, priv. comm.).; (12): Schütz et al. (2005); (13): photometry reduced by us with MOPEX from IRAC archive data. IRAC1, IRAC2 and IRAC3 measurements are saturated.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.