Free Access

Table 3

Results obtained by fitting a power-law spectrum to the XMM-Newton data of G0.9 + 0.1.

Annulus Radius (″) Γ Unabsorbed flux* Surface brightness* χ2/d.o.f.
No. inner outer (10-12 erg cm-2 s-1) (10-16 erg cm-2 s-1arcsec-2)

1 4 10 1.37 ± 0.09 0.63 ± 0.02 24.0 ± 0.6 79/71
2 10 20 1.59 ± 0.07 1.07 ± 0.02 11.3 ± 0.2 97/103
3 20 30 2.01 ± 0.08 0.91 ± 0.02 6.8 ± 0.1 87/81
4 30 45 2.18 ± 0.08 1.18 ± 0.02 3.5 ± 0.1 86/83

Notes. All errors are quoted at the 1σ level.

(*)

Energy range 2.5−10   keV.