Issue |
A&A
Volume 523, November-December 2010
|
|
---|---|---|
Article Number | A22 | |
Number of page(s) | 26 | |
Section | Astronomical instrumentation | |
DOI | https://doi.org/10.1051/0004-6361/201015176 | |
Published online | 11 November 2010 |
Cross-calibrating X-ray detectors with clusters of galaxies: an IACHEC study
1 Department of Physics, Dynamicum, PO Box 48, 00014
University of Helsinki, Finland
e-mail: jukka.h.nevalainen@helsinki.fi
2
Finnish Centre for Astronomy with ESO, University of Turku,
Väisäläntie 20,
21500
Piikkiö,
Finland
3 Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, USA
4
European Space Astronomy Center of ESA, PO Box 78, Villanueva de la Cañada, 28691
Madrid,
Spain
Received:
8
June
2010
Accepted:
29
July
2010
Aims. We used a sample of 11 nearby relaxed clusters of galaxies observed with the X-ray instruments XMM-Newton (EPIC) pn and MOS, Chandra ACIS-S and ACIS-I and BeppoSAX MECS to examine the cross-calibration of the energy dependence and normalisation of the effective area of these instruments as of December 2009. We also examined the Fe XXV/XXVI line ratio temperature measurement method for the pn and MOS.
Methods. We performed X-ray spectral analysis on the XMM-Newton and Chandra data for a sample of 11 clusters. We obtained the information for BeppoSAX from DeGrandi & Molendi (2002). We compared the spectroscopic results obtained with different instruments for the same clusters in order to examine possible systematic calibration effects between the instruments.
Results. We did not detect any significant systematic differences between the temperatures derived in the 2−7 keV band using the different instruments. Also, the EPIC temperatures derived from the bremsstrahlung continuum agreed with those obtained from the Fe XXV/XXVI emission line ratio, implying that the energy dependence of the hard band effective area of the above instruments is accurately calibrated. This also indicates that deviations from ionisation equilibrium and a Maxwellian electron velocity distribution are negligible in the regions studied in the cluster sample. We thus consider the IACHEC sample of clusters of galaxies as standard candles for the calibration of the energy dependence of the hard band (2−7 keV) effective area of X-ray telescopes. On the other hand, the hard band EPIC/ACIS fluxes disagreed by 5−10% (i.e. at 6−25σ level) which indicates a similar level of uncertainty in the normalisations of the effective areas of these instruments in the 2−7 keV band. In the soft energy band (0.5−2.0 keV) there are greater cross-calibration differences between EPIC and ACIS. We found an energy-dependent increase of ACIS versus pn bias in the cross-calibration of the effective area by ~10% in the 0.5−2.0 keV band. This amounts to a systematic difference of (~20%) in the temperatures measured by the ACIS and the EPIC-pn cameras in this band. Due to the high statistical weight of the soft band data, the 0.5−7.0 keV band temperature measurements of clusters of galaxies with EPIC/XMM-Newton or ACIS/Chandra are uncertain by ~10−15% on average. These uncertainties will also affect the analysis of the wide band continuum spectra of other types of objects using ACIS or EPIC.
Key words: instrumentation: miscellaneous / techniques: spectroscopic / galaxies: clusters: intracluster medium / X-rays: galaxies: clusters
© ESO, 2010
1. Introduction
This paper belongs to a series of studies aimed at assessing the cross-calibration status among operational and past X-ray missions promoted by the International Astronomical Consortium for High Energy Calibration (IACHEC)1. In this work, we mainly explore the use of clusters of galaxies for the cross-calibration of the effective area (defined here as the product of the mirror effective area, the detector quantum efficiency and the filter transmission). Unlike many astronomical targets used for X-ray calibration, clusters of galaxies are stable. There is no simultaneity requirement for observing clusters of galaxies with different instruments. Thus, it is possible to obtain large cross-calibration samples of clusters of galaxies which enables a statistically meaningful analysis of systematic effects between X-ray instruments. Clusters of galaxies are relatively bright (L ~ 1045 erg s-1) and thus, the measurements can be performed to a high statistical precision which translates into equally precise information on the calibration. The brightness is not high enough to introduce pile-up problems which is the case with many types of calibration sources. On the other hand, the extended nature of clusters of galaxies introduces additional complexity due to e.g. point spread function and vignetting.
Information on the observations of the sample.
The X-ray spectra of galaxy clusters can typically be described by the combination of collisionally ionised plasma emission components, whose physics is fairly well known. While the energy dependence (i.e. the shape) of the effective area primarily impacts the determination of the cluster temperature, the normalisation of the effective area affects the determination of the emission measure and flux. Comparing temperatures and fluxes measured by different instruments for the same cluster yields information on the cross-calibration of the effective areas. For the hottest clusters, the H-like and He-like FeKα lines (Fe XXV and Fe XXVI) are measurable and thus the temperature-dependent Fe XXV/XXVI line flux ratio provides an additional diagnostic tool for the cross-calibration. These lines cover a narrow energy band where the uncertainties of the calibration of the shape of the effective area do not substantially affect the measurement.
In this work, we use the clusters A1795, A2029, A2052, A2199, A262, A3112, A3571, A85, Coma, HydraA, and MKW3S observed with satellites (instruments) XMM-Newton (pn and MOS), Chandra (ACIS-S and ACIS-I) and BeppoSAX (MECS) (see Table 1). We compared the temperatures and fluxes in order to determine the status of the cross-calibration of these instruments for the implementation of the calibration information as of December 2009.
2. The cluster properties and selected regions
The chosen clusters are nearby (z < 0.08), and bright (the flux in the 2−7 keV band ~10-12−10-11 erg s-1 cm-2) and most host a cool core (see Table 2). These clusters exhibit no major merger signatures in the central regions. The Galactic hydrogen column density is less than 6 × 1020 cm-2 in all of the clusters. The temperature of the gas ranges from ~2 keV to ~10 keV in the cluster sample.
The most significant temperature variation in the relaxed cool core clusters is due to the radial decline of the gas temperature and the central cooling. To minimise the effect of the radial dependence of the gas temperature between observations by different instruments, we aim to extract spectra within the same annular regions near the peak of the cluster temperature profile for a given cluster. This is complicated because of the different obscured areas due to, e.g., CCD gaps in the different instruments. The full annulus set by the chosen inner and outer extraction radii is obscured by ~15% (pn) and ~5% (MOS), on average, in our sample. ACIS-I observations of A85 and Coma cover ~85% of the full annulus, while the ACIS-I observation of MKW3S and all the ACIS-S observations cover 100% of the full annulus. We assume in this work that the differences in the covered areas do not produce significant effects on the derived gas temperatures. We minimise the emission from bright point sources by excluding circular regions with radii of 30′′ centered on the same sky positions in EPIC and ACIS (see Table 3).
We treated the XMM-Newton EPIC instruments pn, MOS1 and MOS2 separately, except in some relevant cases where we analysed the combined MOS1 and MOS2 data for a given cluster and thus formed a single comparison group we identify as MOS. When comparing the temperatures from EPIC instruments only, we used the data extracted from an annular region with an outer radius, rout, of 6 arcmin2.
General information on the sample.
Point source coordinates.
Properties of the clusters.
While the full sample of 11 clusters is observed simultaneously with the XMM-Newton EPIC instruments, only a few clusters have been observed by both ACIS-S and ACIS-I. Our analysis of the ACIS-S and ACIS-I data of Coma and A1795 showed that the broad band temperatures are consistent within the 3% statistical uncertainties and that the broad band fluxes may differ by up to 2−3%. Due to these close agreements, we combine the ACIS-S and ACIS-I results as a single comparison group we identify as ACIS. This group contains all of the 11 clusters. The small FOV of ACIS-S ( ~ 8′ × 8′) sets the limit for the outer radii rout of the spectrum extraction. Depending on the placement of the cluster centre in the chip, the outer radii vary between 2−3′. Thus, for EPIC/ACIS-S comparison we used data for a given cluster extracted from an annular region with the outer radius set by ACIS-S (see Table 4).
Furthermore, for comparison with BeppoSAX MECS, we will use the published 2−10 keV band best-fit single temperature MEKAL values obtained in the central 0−2−4−6 arcmin regions (deGrandi & Molendi 2002). We refer to this paper for the details of the data analysis, including the correction for the point spread function. For comparison with MECS, we extracted pn spectra from the same regions as used for MECS. Due to the limitations of the exposure time and the background, we were able to use 12 regions in 6 clusters in common with the pn and MECS (see Sect. 7.2).
3. Data processing
For each cluster we used the data obtained by such on-axis pointing (see Table 1) which was publicly available in May 2007 and has the largest useful exposure time after the flare-filtering (except that for Coma we used an ACIS-I observation from the year 2008).
3.1. XMM-Newton
We processed the raw XMM-Newton data with the SASv9.0 tools epchain and emchain with the default parameters in order to produce the event files. We used the latest calibration information as of December 2009. We also generated the simulated out-of-time event file, which we later used to subtract the events from the pn spectra registered during the readout of a CCD. We filtered the event files excluding bad pixels and CCD gaps. We further filtered the event files including only patterns 0−4 (pn) and 0−12 (MOS). We used the evselect-3.60.3 tool to extract spectra, images, and light curves, while excluding the regions contaminated by bright point sources. We used the rmfgen-1.55.1 and arfgen-1.76.4 tools to produce the energy redistribution files and the effective area files. When running the arfgen tool, we used an extended source configuration and supplied an XMM-Newton image of the cluster in detector coordinates, binned in 0.5 arcmin pixels, for weighting the response.
3.2. Chandra
The data for each cluster were extracted from the Chandra archive and reprocessed with the CIAO 4.2 version of acis_process_events tool. To examine the effects of recent calibration updates, we analysed the data using CALDB 3.4, CALDB 4.1.1 (which included an updated HRMA effective area) and CALDB 4.2.0 (which includes an updated model for the contamination build-up on the ACIS filters). To filter out background flares, we generated light curves in the 2.5−7.0 keV and 9.0−12.0 keV energy bands using the data from the S1 chip for ACIS-S3 observations and from the S2 chip for ACIS-I observations. All times with background rates exceeding 20% of the mean were excluded from further analysis.
4. Background spectra
Our sample consists of nearby clusters that fill the whole FOV of the detectors and thus a local estimate for the background spectrum is not possible.
4.1. XMM-Newton EPIC
For the XMM-Newton EPIC analysis, we used blank sky−based estimates for the total sky+particle background spectra from Nevalainen et al. (2005). Utilising the > 10 keV ( > 9.5 keV) light curves for the pn (MOS) we only accepted data from such periods when the count rate is within ± 20% of the quiescent level. However, in some cases, this led to very low exposure times. In order to improve the statistical precision for these clusters, we accepted the data accumulated during periods of mild flares, i.e. when the > 10 keV count rate level was lower than 2.0 × the quiescent rate (see Table 1).
In order to account for the variability of the instrumental background due to cosmic rays, we used the sample of EPIC exposures taken with a CLOSED filter (Nevalainen et al. 2005) to extract particle background spectra at the same detector regions as used for the cluster data. We included this additional component in the fits after adjusting its normalisation so that the total background count rate prediction in the 10−14 keV (9.5−12 keV) band for the pn (MOS) matches that in the cluster observation3.
We used the blank sky study of Nevalainen et al. (2005) to estimate the relative uncertainty of our adopted background model in different energy bands and instruments (varying between 5% in the hard band for MOS and 20% in the soft band for the pn). We varied the background model by the appropriate amount and interpreted the change in the best-fit temperature as a systematic effect due to the background uncertainties. We propagated this uncertainty by adding it in quadrature to the statistical uncertainties of the temperature. The background uncertainty has some effect on the temperature measurement in the hard band (at ~ 2% level) for the faintest clusters (A262, A2052, and MKW3S), where the background is the highest (10−15% of the cluster signal). In the soft band, the background level is only a few per cent of that of the cluster signal, and thus the effect of the background uncertainty is negligible.
In this work, we assumed that the sky background emission is absorbed by the same amount of neutral hydrogen as in the cluster field. Thus, in principle, the difference between the hydrogen column density measured along the line-of-sight to the cluster and the average column density affecting the blank sky field pointings may bias the temperature measurements. We used A2052 as a conservative example of the column density bias, because it is the faintest object in our sample in the soft band (the background flux is ~ 6% of the cluster flux in the soft band). Assuming conservatively that the column density of the blank sky sample has the minimum value of all the fields used to generate the background file, i.e. 0.6 × 1020 cm-2 (Nevalainen et al. 2005), the fraction of the absorbed background flux differs by ~ 15% at 0.5 keV from that obtained with the column density used for A2052 (2.7 × 1020 cm-2). Thus, we overestimate the background model, i.e. underestimate the background-subtracted signal by ~ 1% at 0.5 keV for A2052. At higher energies and for the brighter clusters the effect is smaller. Thus, the uncorrected column density variation in the blank sky and cluster fields has a negligible effect on our results.
4.2. Chandra ACIS
For ACIS, we extracted background images from the standard set of cti-corrected ACIS blank sky images in the Chandra CALDB (Markevitch et al. 2003). The exposure times in the background images were adjusted to produce the same 9.0−12.0 keV count rate as in the cluster observations. Except for A85, A2029 and A2199, all observations were done in very faint (VF) telemetry format and the VF background filtering was applied using the CIAO tool acis_process_events. The same VF background screening was applied to the background data sets by only including events with “status = 0”.
We estimated the effect of background modelling uncertainties (i.e. the statistical uncertainty in the 9.0−12.0 keV band used for normalisation and the spectral variability in the band used for the cluster analysis) by varying the background normalisation by ± 10%. We propagated in quadrature the shift in the best-fit value to the parameter uncertainties.
5. Analysis methods
We performed an X-ray spectroscopic analysis for all the data of our cluster sample (see Sect. A). The temperature measurement is primarily driven by the shape of the bremsstrahlung continuum for clusters with kT ≳ 2 keV. Thus, the accuracy of the temperature measurement is sensitive to the accuracy of the calibration of the energy dependence of the effective area (see Sect. B.1.2). The comparison of continuum temperatures measured with different instruments for the same cluster yields information on the cross-calibration accuracy of the energy dependence of the effective areas. The normalisation of the effective area affects the derived emission measure and flux. Thus, the comparison of cluster fluxes enables an evaluation of the uncertainties of the cross-calibration of the normalisation of the effective areas.
5.1. Spectral fits
For the spectral analysis, we modelled the emission with a single-temperature MEKAL model (Kaastra 1992). We used the metal abundances of Grevesse & Sauval (1998). We used the optical measurements of cluster galaxies found from the NASA Extragalactic Database for the cluster redshift. To model the effect of the Galactic absorption, we applied the PHABS model. We fixed the column density to the value obtained from 21 cm radio observations (Kalberla et al. 2005) and used the absorption cross sections of Balucinska-Church & McCammon (1992).
We binned the spectra to contain a minimum of 100 counts per bin. We fitted the background-subtracted (see Sect. 4) spectra in different energy bands: 0.5−7.0 keV (wide band), 0.5−2.0 keV (soft band) and 2.0−7.0 keV (hard band). We allowed the temperature, metal abundance and the model normalisation to vary in the fits, unless stated otherwise. We used the best-fit emission measures to determine the cluster fluxes.
5.1.1. Fe XXV/XXVI line ratio method
In the spectral analysis described above, the shape of the bremsstrahlung continuum dominates the temperature measurement in broad energy bands. However, the temperature dependence of the Fe ionisation fraction can also be used as an additional, independent temperature measurement. In practise, the Fe XXV/XXVI line flux ratio is the most useful ionisation temperature measurement in hot clusters of galaxies. The energy resolution of EPIC and ACIS instruments is adequate for resolving these two lines. The lines are centred at ~ 6.7 and ~ 7.0 keV in the rest frame of the clusters.
We measured the ionisation temperature by fitting the spectra in a band of 0.8 keV width centred on the mean value of the redshifted Fe line energies (=6.85 keV / (1+z)) with a MEKAL model. To yield enough channels in this narrow band, we grouped the data with a requirement that each channel contains a minimum of 50 counts.
5.2. Statistical analysis
By comparing the spectroscopic results (temperatures (T) and fluxes (F)) of our cluster sample we addressed the issue of systematic uncertainties in the calibration of the different instruments. For each cluster, and a given pair of instruments, we computed the difference of the temperature or the flux measurements and its statistical uncertainty, in terms of a fraction of the average value (fT = ΔT / ⟨ T ⟩ and σfT = σΔT / ⟨ T ⟩ ; fF = ΔF / ⟨ F ⟩ and σfF = σΔF/ ⟨ F ⟩ ). Using these values we calculated the weighted mean and its statistical uncertainty at 1σ level. A systematic uncertainty in the calibration would tend to drive the mean of the distributions away from zero. We evaluate the significance of the deviation of the weighted mean from zero in terms of its statistical uncertainty.
6. Minimising the number of temperature components
For optimal calibration, the spectra of the chosen targets should be as simple as possible. We use a single-temperature plasma emission model in our analysis, to make a comparison between different instruments. Possible multi-temperature components in the ICM complicate the issue, because different instruments have different energy dependent effective areas which will weight the cooler and hotter emission differently (e.g. Mazzotta et al. 2004). Thus, even a 100% accurate calibration in all instruments may lead to different single-temperature measurements, if a very complicated temperature structure is present in the cluster. This is unlikely in our sample because it contains the most relaxed nearby clusters known in literature and we only extract spectra near the peak of the temperature profile. We investigate in Sect. 6.1 the effects of the central cooling and the temperature decline at large radii present in relaxed clusters.
6.1. Central cooling
We aim to minimise the effect of the central cooling in our cluster sample by simply excluding the emission from the cool cores in our analysis. Vikhlinin et al. (2005, 2006) showed that in most clusters the central cooling is confined within the central 70 kpc. At the redshifts of our cluster sample, 70 kpc corresponds to angular diameters of 0.8−1.7′. We constrained the inner radius of our spectral extraction regions to be greater than 70 kpc4. A3571 and Coma are exceptions to this rule, because they do not exhibit any central cooling. We excluded the central 1′ region of Coma to avoid the contribution from the central galaxy NGC 4874.
6.2. Radial temperature gradient
Most clusters feature a radial temperature profile that decreases at large radii, as found, e.g. from the Chandra analysis by Vikhlinin et al. (2005, 2006). Over the 3-dimensional radial range of 0.1−0.3r500 the cluster temperature profiles are rather flat, i.e. they vary by less than 15%. We estimated the value of r500 for our sample by using the T−r500 scaling relation of Vikhlinin et al. (2006) and approximating the maximum temperature Tpeak using our single-temperature pn fits in the 2.0−7.0 keV band (see Table 4). For the cool core clusters, we further calculated the 3D temperature profile using the model for the sample average in Vikhlinin et al. (2006). The calculations showed that, except for the nearest cluster A262, most of the radial ranges used for the spectrum extraction in our sample are within the rather isothermal range of ~0.1−0.3 r500 (see Fig. 1).
![]() |
Fig. 1 The solid lines show the average 3D temperature profiles from Vikhlinin et al. (2006) for each cool core cluster in our sample. The models are plotted as a function of the 3D radius in units of r500, starting from the radii corresponding to rin when projected to the plane of the sky, extending to rout used for extracting the pn/MOS spectra. The solid vertical bars indicate rout used for extracting the spectra for EPIC/ACIS comparison. The dashed vertical lines denote the approximately isothermal region of 0.1−0.3 r500. |
In order to characterise the gas density distribution, we constructed surface brightness
profiles using ACIS data, except that for Coma we used the published results from ROSAT
analysis (Briel et al. 1992). We fitted the profiles
with a single-β or double-β model (1)where
b is the projected radius. We used the best-fit parameters (see
Table 4) to distribute the gas density with
radius. We divided the cluster in concentric spherical shells and assigned each shell with
a density and temperature given by the above models. We then intersected the spherical
shells with a hollow cylinder with the inner and outer radii given in Table 4, which represent the projected spectral extraction
region, and computed the intersecting volumes of each shell. Finally, we calculated the
emission measure of each shell at different temperatures along the line of sight.
We found that 4−17% of the emission in the regions used for the EPIC/ACIS comparison originates from outside the nearly isothermal region (i.e. from 0.3−1.0 r500, see Table 4). A3112 has the largest fraction (17%) of its projected emission originating from the non-isothermal region and we thus used it as a conservative example on the effect of the possible temperature bias due to the temperature gradients in our sample. We used the above projected temperatures and emission measures to form a composite spectrum model and used it to simulate data for pn, MOS1 and MOS2 and ACIS-S using XSPEC. We fitted the simulated isothermal emission (originating from 0.1−0.3 r500 ) and the total emission (originating from 0.1−1.0 r500) with a single-temperature MEKAL model. The exercise showed that the effect of including the emission from 0.3−1.0 r500 was to reduce the measured temperatures by ~3%. Importantly, all instruments yielded the same temperature in all energy bands within ~0.1% when we included the emission from 0.3−1.0 r500. Thus, in our sample, the projected lower temperature emission due to temperature gradient does not introduce a significant bias in the derived temperatures between different instruments or energy bands.
6.3. PSF scatter
A complication when comparing Chandra and XMM-Newton spectra is that the point spread function (PSF) of the pn (FWHM ~ 6′′) and MOS (FWHM ~ 5′′) (see XMM-Newton Users’ Handbook5) is larger than that of ACIS. The tail in the King-profile shape of the EPIC PSF results in 90% encircled radius of ~40−50′′, while the corresponding value for ACIS is 1−2′′ in the 0.5−7.0 keV band (see The Chandra Proposers’ Observatory Guide6). Thus, when a bright cool core is present in a cluster, the tail of the PSF distribution may scatter a significant fraction of the central emission into the regions we examine in this work. This effect is greater in EPIC due to its wider PSF, and this may introduce a bias towards lower temperatures measured with the EPIC instruments.
To minimise the effect of scattered emission from the bright cool core, we additionally required that the inner extraction radius for each cluster must be greater than 1.5 arcmin (i.e. ~2 times the 90% encircled radius) for the cool core clusters. The inner radius of the spectral extraction region was therefore set to the maximum between the cool core exclusion radius (see Sect. 6.1) and the PSF core exclusion radius defined above except for the clusters without the cool core. We then estimated the contribution of the PSF-scattered flux within our adopted spectral extraction regions. We performed these calculations for the pn, which has the greatest effect. We used analytical expressions for the PSF profile of the pn from Ghizzardi (2002). The weak energy dependence of the PSF produces a negligible effect in the 0.5−7.0 keV band and we thus report the contributions assuming that all photons have an energy of 2 keV.
We convolved the Chandra surface brightness model (see Table 4) from a given input radial region with the pn PSF profile and calculated its relative contribution to the flux within a given output radii for pn. The calculations showed that the contribution from the cool inner 70 kpc radius to the total emission projected within rin and rout ranges between 0.3% and 6% (see Table 4).
To obtain a conservative estimate for the uncorrected PSF effect, we further examined A2052, which has the greatest PSF scattering contribution. We used the published Chandra temperature profile of A2052 (Blanton et al. 2003) to approximate the temperature within our projected radii rin and rout (~3.5 keV) and within the central 70 kpc (~2.5 keV). Using XSPEC simulations, we then produced a composite spectrum containing two MEKAL components with the above temperatures in the proportion estimated by the PSF scattering calculations. We then fitted the composite spectrum with a single temperature MEKAL model, to approximate the effect of uncorrected PSF contribution. The spectral analysis shows that the effect of the PSF scattering is to reduce the best-fit pn temperature by ~2%, independent of the band choice used in the spectral analysis. Due to its smaller PSF, the effect is smaller for MOS and ACIS. Thus, the PSF scattering may cause differences in the temperature measurements with different instruments by a maximum of 2%, which is negligible compared to the statistical uncertainties.
![]() |
Fig. 2 The upper panels show the best-fit temperatures (asterisks) and the 1σ uncertainties (boxes) in the hard band obtained with the XMM-Newton instruments pn (left panel), MOS1 (middle panel) and MOS2 (right panel). The lower panels show the relative temperature difference, fT = ΔT / ⟨ T ⟩ (diamonds), and its 1σ uncertainty for MOS1-pn (left panel), MOS2-pn (middle panel) and MOS2-MOS1 (right panel). The dotted and dashed lines show the weighted mean of fT ± the error of the mean. |
7. Hard band temperatures
We first restricted the spectroscopic analysis to the hard band (2.0−7.0 keV). This was motivated by the fact that the modelling of the cluster emission is less complex because the galactic absorption does not affect the emission at these energies. Also, the choice of 2 keV for the break between the soft and the hard bands allows us to have some control on the calibration of the different instrumental components. The EPIC optical filter transmission is essentially 100% in the hard band, while it is significantly smaller in the soft band. The molecular contamination on the ACIS filters (see below) also affects only the lowest energies. The quantum efficiency of the pn is essentially 100% in the hard band, and thus the effective area of the pn primarily depends on the effective area of the mirrors. For MOS and ACIS, the quantum efficiency is less than 100% in the hard band and the different components cannot be distinguished.
7.1. EPIC temperatures
Best-fit hard band temperatures and 1σ uncertainties for EPIC instruments.
![]() |
Fig. 3 The best-fit temperatures (asterisks) and the 1σ uncertainties (boxes) in the hard band obtained with the pn vs. those obtained with MOS (i.e. combined MOS1 and MOS2 spectra). |
7.2. XMM-Newton vs. BeppoSAX temperatures
We found that the pn hard band temperatures only differ by ~1% (0.9σ) from the BeppoSAX MECS values on average (see Fig. 4 and Table 6). The pn values are not systematically higher or lower than the MECS values.
7.3. XMM-Newton vs. Chandra temperatures
Our spectral fits to the pn and ACIS data using CALDB 4.2.0 (see Figs. A.1 and A.3) showed that the ACIS hard band temperatures differ from the pn values only by ~1% (0.6σ) on average (see Fig. 5 and Table A.1) implying similar accuracy for the cross-calibration of the energy dependence of the effective area between ACIS and EPIC in the hard band.
![]() |
Fig. 4 The upper panel shows the best-fit temperatures (asterisks) and 1σ uncertainties (boxes) in the hard band obtained with the XMM-Newton pn and BeppoSAX MECS instruments. The lower panel shows the relative MECS-pn temperature difference, fT = ΔT / ⟨ T ⟩ (diamonds), and its 1σ uncertainty. The dotted and dashed lines show the weighted mean of fT ± the error of the mean. |
Best-fit hard band temperatures and 1σ uncertainties for pn and MECS.
8. Fe XXV/XXVI line ratio
In this Chapter, we explore the Fe XXV/XXVI line ratio method for the determination of gas temperatures.
8.1. Statistical issues
We obtain the Fe XXV/XXVI line ratio temperatures by fitting the data with the MEKAL model in the ~6−7 keV energy band, depending on the cluster redshift (as explained in Sect. 5.1.1). We first attempted to estimate whether the accuracy of the method depends on the number of photons available for the analysis. For this, we performed a spectral analysis of data simulated with the MEKAL model in XSPEC. We used the pn energy redistribution and auxiliary files of A1795 for the simulations. We used a range of 5−10 keV for the temperatures in the simulations and kept the metal abundance at 0.3 Solar and a redshift of zero in the simulations. We varied the number of input counts in a 6.45−7.25 keV energy band by scaling the input model accordingly. For each temperature and number of counts, we performed 1000 simulations, including the scatter due to counting statistics.
We binned the simulated spectra to contain a minimum of 50 counts in each channel, as we do when fitting the actual data. We then fitted each of the simulated spectra in the 6.45−7.25 keV band and thus obtained a distribution of best-fit temperatures for each input temperature and number of counts. We used these distributions to determine the median temperatures and compared them with the input values. The comparison showed that while the derived temperatures agreed with the input values within 1% at the highest numbers of counts (>3000), at the low count numbers there is a tendency towards higher temperatures, especially for the lowest input temperatures (see Fig. 6). This effect was identical regardless of whether we used χ2 or C-statistics. At the lowest temperatures, the Fe XXVI line emission is quite weak and it is possible that the Fe XXVI line-like features are created at random due to low statistics. These artificial features are then interpreted as real Fe XXVI emission and the temperatures are biased high, as measured above.
![]() |
Fig. 5 The best-fit temperatures (asterisks) and the 1σ uncertainties (boxes) in the hard band obtained with the XMM-Newton pn detector vs. those obtained with the Chandra ACIS detector using CALDB 4.2.0. |
![]() |
Fig. 6 The relative bias of the temperature derived by fitting the simulated spectra in the 6.45−7.25 keV band as a function of the number of counts for the input values kT = 5−7 keV (dotted blue lines) and for kT = 8−10 keV (solid lines). The dash-dot line shows the allowed upper limit of 2% for the bias in the sample. |
Systematic effects on the temperature measurement.
![]() |
Fig. 7 The best-fit MEKAL models (solid line) in the ~6−7 keV band data which contain the Fe XXV and Fe XXVI emission lines and statistical uncertainties (crosses). The pn (left panel) and MOS (right panel) data and the models are arbitrarily scaled for the clarity of the display. |
8.2. Systematic uncertainties
The accuracy of the Fe XXV/XXVI line ratio measurement additionally depends on the accuracy of the absolute energy scale and the energy resolution used to generate the redistribution matrix in the ~6−7 keV band. Also, uncertainties in the redshift measurement and the atom physics used to generate the MEKAL model have some effect to the interpreted temperature for a given line ratio data. We found that these effects (see Appendix B, for the details), combined with the bias due to limited number of counts (Sect. 8.1) may affect the EPIC temperatures at the ~4% level (see Table 7). We will consider this uncertainty and propagate it along with the statistical uncertainties of EPIC Fe XXV/XXVI temperatures when appropriate in the following.
8.3. Results
We then fitted the EPIC data of the subsample described in Sect. 8.1 (see Fig. 7) in the ~6−7 keV band with a single-temperature MEKAL model. To obtain a similar level of counts as in the pn instrument, we co-added the MOS1 and MOS2 data for comparison.
The relatively small number of photons in the narrow energy band (6.45−7.25 keV in the rest frame of a cluster) inevitably limits the statistical accuracy of the derived temperatures. The relative 1σ statistical uncertainty on the temperatures is at most 20% (see Table 8). In the 6.45−7.25 keV energy band, the metal abundance and the emission measure are highly degenerate: a lower normalisation for the continuum is approximately compensated with a higher metal abundance, since the continuum cannot be well separated from the line profile in this narrow energy band (see Fig. 8).
Best-fit temperatures and statistical uncertainties for the EPIC instruments in the ~6−7 keV band.
On the other hand, we have already constrained the emission measure when fitting the hard band (2−7 keV) (Sect. 7), typically within 1% at 1σ level. We thus experimented by constraining the emission measure to that found in the hard band fit, when fitting the ~6−7 keV band. The resulting statistical uncertainties for the temperature are 3−10%, instead of 5−20% in the case of a free emission measure (see Table 8). Thus, with this method, we reach the level of the systematic uncertainties in some cases (see Table 7). In both cases, the temperatures are consistent within the statistical 1σ uncertainties. Importantly, the temperatures obtained with the free or constrained emission measure in the ~6−7 keV band do not indicate a systematic difference (see Table 8). This proves that the use of the hard band emission measure constrain does not introduce any bias to the EPIC temperature measurements.
The pn and MOS temperatures obtained with the hard band emission measure constrain mostly agree within the statistical 1σ uncertainties (see Table 8 and Fig. 9). The values differ somewhat for A1795 and A3571, which have the smallest statistical uncertainties. Considering the systematic uncertainties, the values agree. There is no systematic difference between the derived temperatures for the full sample obtained with the two instruments. Thus, in the following we will refer to the Fe XXV/XXVI temperatures obtained with the emission measure constrain.
8.4. Fe XXV/XXVI line ratio vs. continuum
The ~6−7 keV band temperatures above are given by the temperature dependence of the ionisation fraction, i.e. by the Fe XXV/XXVI line ratio. On the other hand, the hard band temperatures are primarily determined by the temperature dependence of the bremsstrahlung continuum. There are several reasons why the two measurements may not agree. Due to cluster mergers, the intracluster material may be in a non-equilibrium ionisation state which would change the Fe XXV/XXVI line ratio from that given by ionisation equilibrium assumed in our work (e.g. Prokhorov 2010; Akahori & Yoshikawa 2010). The mergers may also accelerate a fraction of electrons into suprathermal velocities, which will produce deviations from a Maxwellian electron velocity distribution assumed when modelling the continuum emission with a bremsstrahlung model (Prokhorov et al. 2009). Also, the non-Maxwellian electron distribution will affect the Fe XXV/XXVI line ratio (e.g. Kaastra et al. 2009). Furthermore, a relativistic electron population created by a strong merger shock may produce an additional continuum emission component via inverse compton scatter of cosmic microwave background photons (e.g. Sarazin 1988). These effects are probably small in our sample because we used the most dynamically relaxed clusters. Also, we excluded the cluster outskirts, which may still be accreting material and where ionisation equilibrium may not yet have been established.
With the current XMM-Newton EPIC data we are able to test the above possibilities by a direct comparison of the temperatures derived from both the continuum and the Fe XXV/XXVI line ratio. To keep the two temperature measurements as independent as possible, we derived the continuum temperature using a MEKAL fit in the 2.0−6.0 keV band. In this band, the line emission is negligible for hot clusters and thus the metal abundance may be inaccurately determined. We examined this issue by fixing the metal abundance to values in the range 0.0−0.5 solar. Examining the best-fit models showed that the temperatures varied by less than 1% for a given cluster when varying the abundance. Thus, uncertainties in the metal abundance do not significantly bias the temperature measurements.
The comparison of the temperatures derived by fitting the 2.0−6.0 keV and ~6−7 keV band reveal a good agreement between the two methods (see Fig. 10): the PN temperatures differ by ~1% (0.2σ) while MOS differences are ~7% (1.6σ) on average. There is no systematic difference between the measurements. This implies that the calibration of the energy dependence of the effective area of the EPIC instruments in the hard band is accurate and that the deviations from the ionisation equilibrium state and Maxwellian electron velocity distribution in these clusters are negligible. Given our evidence for the Fe XXV/XXVI line ratio measurement being insensitive to calibration uncertainties in the effective area (see Appendix B.1), the above finding could be useful for the calibration of the hard band of future X-ray missions: the hard band calibration should be fine-tuned to yield the same temperature as does the Fe XXV/XXVI line ratio.
![]() |
Fig. 8 The 2-parameter confidence contours at 1σ for A2029 obtained with the MEKAL fits to the pn data in the ~6−7 keV band. |
![]() |
Fig. 9 The best-fit temperatures (asterisks) obtained with the MEKAL fits in the ~6−7 keV band data of the pn vs. those obtained with MOS. The solid boxes indicate the statistical uncertainties at 1σ level while the dotted boxes include the systematic uncertainties. |
![]() |
Fig. 10 The upper panels show the best-fit temperatures (asterisks) and 1σ uncertainties (boxes) for the Fe XXV/XXVI line ratio temperatures vs. the 2−6 keV band continuum for the pn (left panel) and MOS (right panel). The lower panels show the relative temperature difference fT (i.e. the 2−6 keV band continuum temperature minus the Fe XXV/XXVI line ratio temperature, divided by the mean of the two) and its 1σ uncertainty for the pn (left panel) and MOS (right panel). The dotted and dashed lines show the weighted mean of fT ± the error of the mean. |
9. Soft band temperatures
We then performed a spectroscopic analysis of the data in the soft band (0.5−2.0 keV). We used a single-temperature MEKAL model, as in the analysis of the hard band above. We allowed the temperature, metal abundance and emission measure to vary independently from the hard band values presented above. This was required in order to obtain statistically acceptable fits in the soft band (see Figs. A.2 and A.4, for pn and ACIS). Note that the formally accurate models for the soft and hard bands, which are adequate for calibration work, do not yield a physically consistent modelling of the full energy band. In order to keep the modelling and the temperature comparison simple, we excluded the coolest cluster A262 from this comparison, because its strong line emission at ~1 keV would require multi-component modelling for an accurate description of the data.
9.1. pn vs. MOS
We found that while the pn and MOS2 agree very well (average difference is ~1%, i.e. 0.5σ), the MOS1 values are ~5% (~3.7σ) higher than those of the pn and MOS1 (see Fig. 11). These differences indicate some remaining cross-calibration uncertainties in the EPIC instruments in the soft band which we will not examine in more detail here.
9.2. pn vs. ACIS
We found that the ACIS soft band temperatures are ~18% higher than those obtained with the pn (see Fig. 12). This difference is statistically very significant, 8.6σ, and thus there are significant remaining ACIS/pn cross-calibration uncertainties in the soft band.
![]() |
Fig. 11 The upper panels show the best-fit temperatures (asterisks) and statistical 1σ uncertainties (boxes) in the soft band with the XMM-Newton instruments pn/MOS1 (left panel), pn/MOS2 (middle panel) and MOS1/MOS2 (right panel). The lower panels show the relative temperature difference fT (=ΔT/⟨ T ⟩, diamonds) and its 1σ uncertainty for MOS1-pn (left panel), MOS2-pn (middle panel) and MOS2-MOS1 (right panel). The dotted and dashed lines show the weighted mean of fT ± the error of the mean. |
![]() |
Fig. 12 The upper panels show the best-fit temperatures (asterisks) and 1σ uncertainties (boxes) in the soft band for the pn and ACIS (left panel) and in the hard and soft bands for ACIS (right panel). The lower panels show the relative temperature difference, fT = ΔT / ⟨ T ⟩ (diamonds) and its statistical 1σ uncertainty for ACIS soft band – pn soft band (left panel) and ACIS soft band – ACIS hard band (right panel). The dotted and dashed lines show the weighted mean of fT ± the error of the mean. |
To examine this difference in more detail, we convolved the best-fit soft band pn models through the ACIS responses and compared this prediction with the ACIS data. In the case of A85 and Coma the data are spread across several CCD chips and for these clusters we co-added the data and formed a single average file for the responses and background. We scaled the models to match the ACIS data at 2 keV, since we are primarily interested in the energy dependence of the effective area here, whose cross-calibration is very accurate in the 2−7 keV band (see Sect. 7).
![]() |
Fig. 13 The ratio of the ACIS data to the pn model prediction using the best-fit pn model and the ACIS responses. The model has been normalised so that the ratio equals unity at 2.0 keV. The dashed line shows the best-fit linear relation. |
We found that the ratio of the ACIS data to the pn model prediction exhibits a systematic trend in most clusters. Fitting the data-to-model ratio with a linear function we found that while the ratio is 1.0 at 2 keV by definition, it decreases to ~0.9 at 0.5 keV in most clusters (see Fig. 13). This implies that either the effective area of the pn is underestimated, or that of ACIS is overestimated at 0.5 keV by ~10%.
10. Wide band temperatures
Since both the intrinsic cluster flux and the effective area of EPIC and ACIS are higher in the soft band, the statistical weight of the soft band data is much greater than that of the hard band. As shown above, the greatest differences between the accuracy of the EPIC and ACIS effective areas are below 2 keV which thus affect the temperatures derived in the wide band (0.5−7.0 keV). For the interest of the general user, we also evaluated the effect of the cross-calibration uncertainties when fitting the 0.5−7.0 keV band with a single-temperature model as is often done in the literature. Since the hard and soft band temperatures are inconsistent in all clusters and for all instruments, the application of a single-temperature model in the wide band will result in some residuals. These residuals are usually hidden by the larger statistical uncertainties in detailed temperature profile measurements presented in the literature.
As expected, due to the above findings (Sect. 9.2), ACIS yields systematically higher wide band temperatures than EPIC. On average, the ACIS/MOS1, ACIS/MOS2 and ACIS/pn differences are ~8%, ~15% and ~14% which corresponds to a very high detection significance of 10.0σ, 18.9σ and 18.0σ. The maximum difference is ~25% (see Fig. 14). These values may be taken as a systematic uncertainty in the wide band temperature measurement when using EPIC or ACIS data. These uncertainties also apply to the analysis of EPIC and ACIS wide band continuum spectra of other types of objects. Evaluation of this effect remains to be carried out by analysis of e.g. blazars observed simultaneously with XMM-Newton and Chandra .
![]() |
Fig. 14 The upper panels show the best-fit temperatures (asterisks) and 1σ uncertainties (boxes) in the wide band using pn or ACIS data. The lower panel shows the relative ACIS-pn temperature difference fT (=ΔT/⟨ T ⟩, diamonds) and its statistical 1σ uncertainty. The dotted and dashed lines show the weighted mean of fT ± the error of the mean. |
![]() |
Fig. 15 The upper panels show the best-fit temperatures (asterisks) and statistical 1σ uncertainties (boxes) in the soft and hard bands for XMM-Newton instruments pn (left panel), MOS1 (middle panel) and MOS2 (right panel). The lower panels show the relative soft-hard temperature difference fT (=ΔT / ⟨ T ⟩, diamonds) and its statistical 1σ uncertainty for pn (left panel), MOS1 (middle panel) and MOS2 (right panel). The dotted and dashed lines show the weighted mean of fT ± the error of the mean. |
11. Hard band vs. soft band temperatures
With our data set we can also compare the temperature measurements in the hard and soft bands. In principle, this could be an useful tool for discovering emission components in addition to the bulk of the isothermal emission.
We found that all of the XMM-Newton soft band temperatures are significantly smaller than the hard band values (see Fig. 15 and Tables 5 and 9): The pn, MOS1 and MOS2 soft band temperatures are ~30−35% (~22−30σ) lower than those obtained in the hard band. Also, most of the ACIS soft band temperatures are lower than the hard band values, but by a smaller amount, 12% (1.6σ, see Fig. 12 and Table A.1). It would be useful to examine whether this effect is present in the data of objects of different type. While the scatter is quite large and no clear patterns can be seen, there is some indication that the relative difference increases with temperature.
These systematic differences between the hard and soft band temperatures in all instruments could be explained by deviations from the isothermal emission. Since we have minimised the gas cooling effect, among the candidates for the excess emission are multi-temperature gas due to, e.g., clumping or cluster mergers and the Inverse Compton scatter of Cosmic Microwave Background photons from relativistic cluster electrons (see Durret et al. 2008; Rephaeli et al. 2008, for recent reviews). Typically this excess emission flux is ~10% of the isothermal component. We found above that there are remaining uncertainties in the calibration of the effective area in the studied instruments at this level in the soft band. Due to these possible astrophysical effects in the clusters of galaxies, they are not a good choice for calibrating the 0.5−2.0 keV band and other sources should be used (e.g. white dwarfs and isolated neutron stars).
The soft band temperatures and 1σ uncertainties using EPIC instruments.
12. Fluxes
![]() |
Fig. 16 The relative flux difference, fF = ΔF / ⟨ F ⟩ (diamonds) and its statistical uncertainties in the hard band (upper row) and in the soft band (lower row) are shown as a function of pn hard band temperature for different instrument pairs. The dotted and dashed lines show the weighted mean of fF ± the error of the mean. |
We then examined the fluxes given by the best-fit MEKAL models in the hard and soft bands. We calculated the statistical 1σ uncertainties of the flux measurements by considering the variation of all the free MEKAL parameters. We limited the pn-MOS comparison within the smaller outer extraction radii used for ACIS (see Sect. 2). Due to the CCD gaps and bad columns in the central regions the fraction of the useful detector area to the full annulus given by the extraction radii is less than 100% (except for ACIS-S), and varies between the instruments for a given cluster. Also the exclusion of the point source regions reduces the useful detector area. To enable a meaningful comparison of the fluxes derived with different instruments, we divided the measured flux by the fraction of the covered full annulus to recover the intrinsic cluster flux measured by each instrument. Since the emission is not constant with radius, the linear scaling may produce some differences for the fluxes derived with different instruments for a given cluster due to the differences in the covered areas (see below).
Since the half-width of the extraction region is in most cases comparable to the 90% encircled radius (~40−50 arcsec) of EPIC we expect that ~10% of the flux originating within the extraction region will end up outside the studied region (≡ out-flux). We confirmed this by convolving the surface brightness models with the pn PSF and calculating the number of counts in different regions. However, the flux originating outside of the extraction region and ending up to the extraction region (≡ in-flux) compensates very accurately the out-flux. Thus the net effect is that the true cluster flux within our extraction regions is affected by less than 0.5% due to PSF scatter in our sample. The very accurace cancellation of the in-flux and out-flux is a consequence of an approximately constant count rate within annuli of constant width towards smaller or bigger radii within the PSF radius of 1 arcmin. This in turn is due to the opposite effects of decreasing surface brightness and increasing area of the annuli with an increasing radius.
12.1. pn vs. MOS
We found that while the MOS2 hard band fluxes are in average only ~3% lower than those of MOS1, the difference is very significant (6.2σ, see Fig. 16 and Table 10). There are bigger differences between the pn and the MOS: MOS1 hard band fluxes are higher by ~7% (15.4σ) while MOS2 hard band fluxes are higher by 5 ~ % (10.0σ) than those measured by the pn. The differences between the pn and MOS are similar in the soft band. This flux difference between the pn and MOS was reported earlier by e.g. Stuhlinger et al. (2008) and Mateos et al. (2009). While qualitatively consistent with the analysis of the 2XMM catalogue in Mateos et al. (2009) (when considering similar off-axis angles (0−2 arcmin) and energy bands (0.5−12 keV)) our pn/MOS differences are somewhat smaller. Our results are consistent with other IACHEC work based on a sample of blazars (Smith et al. 2010, in prep.)
The fluxes in the hard band (2−7 keV) given by the best-fit single-temperature MEKAL model.
12.2. EPIC vs. ACIS
We then compared the EPIC fluxes to those obtained using ACIS data and CALDB version 4.2. We found that the scatter of the flux between the pn and ACIS (~6%) around the mean value in both bands is much larger than the statistical uncertainties of the flux measurements (~1%). This implies a systematic uncertainty component which varies from cluster-to-cluster. We examined this by restricting the spectral extraction regions to the common sky area where all the cameras have full coverage but this did not decrease the scatter significantly. We also experimented using two-temperature models with similar results. We further examined whether the differences in the shapes of the best-fit models between different instruments contribute to the flux scatter. We fitted the MOS and ACIS data with the best-fit pn model, allowing only the normalisation to be a free parameter. This did not reduce the scatter either.
In the hard band, the ACIS fluxes are systematically and significantly higher than the pn fluxes, by 11 ± 0.5% (24.7σ) on average (see Fig. 17). There is a trend of increasing relative flux difference with increasing temperature. ACIS flux values also exceed those of MOS1 and MOS2, but by a smaller amount: 3 ± 0.5% (6.1σ) and 6 ± 0.5% (12.8σ), respectively. Thus, our analysis shows that the hard band fluxes using the pn, MOS or ACIS instruments, might differ by 5−10% due to similar uncertainty of the calibration of the normalisation of the effective areas in the hard band.
In the soft band, the agreement between ACIS and the pn is much better than in the hard band: the fluxes differ only by ~2% on average (see Fig. 17). This is interesting when noting that the soft band temperatures between EPIC and ACIS disagreed substantially (see Sect. 9).
![]() |
Fig. 17 The relative flux difference, fF = ΔF/ ⟨ F ⟩ (diamonds) and its statistical uncertainties between ACIS and pn in the soft band (left panel) and the hard band (right panel) are plotted against the pn hard band temperature. The dotted and dashed lines show the weighted mean of fF ± the error of the mean. |
13. Chandra calibration changes
In last few years (2007−2009) a considerable effort has been devoted into re-analysing the ground-based calibration of Chandra. Here we examined how the temperatures and fluxes depend on the version of the Chandra calibration data base (CALDB), i.e. CALDB 3.4 (Dec. 2006), CALDB 4.1.1 (Jan. 2009) and CALDB 4.2 (Dec. 2009), (see e.g. David et al. 2007, 2009).
13.0.1. CALDB 3.4
After the Chandra launch, gratings observations of AGN showed that the mirror reflectivity near the Ir-M edge was 15% higher than predicted by the HRMA effective area model. In CALDB 3.4, a new HRMA effective area model was released which included a 22 Å layer of hydrocarbon contaminant on the mirrors and reproduced the observed reflectivity across the Ir-M edge. In our earlier work (Nevalainen et al. 2007) we found that this model yielded higher hard band temperatures for clusters hotter than ~4 keV when compared to values derived with the XMM-Newton EPIC detectors using the calibration as of Aug. 2007. Similar results have been obtained with an older version of Chandra calibration (Vikhlinin et al. 2005; Kotov et al. 2005; Snowden et al. 2008).
In the current work we found that the Chandra CALDB 3.4 hard band temperatures exceeded those obtained with the pn using the latest EPIC calibration information in Dec. 2009 by an average of ~10% (see Figs. 18 and 19 and Table A.1). The maximum temperature difference between the EPIC Dec. 2009 calibration and ACIS CALDB 3.4 is ~30%.
![]() |
Fig. 18 The upper panels show the best-fit temperatures (asterisks) in the hard band obtained with XMM-Newton pn vs. those obtained with Chandra ACIS using CALDB 3.4 (left panel), CALDB 4.1.1 (middle panel) and CALDB 4.2 (right panel). The lower panels show the relative ACIS-pn temperature difference, fT = ΔT / ⟨ T ⟩ (diamonds) and its 1σ uncertainty. The dotted and dashed lines show the weighted mean of fF ± the error of the mean. |
![]() |
Fig. 19 The relative differences of the soft and hard band temperatures (two upper rows) and fluxes (two lower rows) between the pn and ACIS at different stages of ACIS calibration (different columns). The values are shown as a function of the hard band pn temperatures. Note that the scaling of the y-axis is different in different rows. The average values are marked with a dotted line. |
13.0.2. CALDB 4.1.1
Following our cluster temperature chandra/XMM-Newton cross-calibration work (Nevalainen et al. 2007), the ground-based HRMA calibration data taken at the X-ray Calibration Facility (XRCF) at MSFC was re-analysed. It was found that the molecular contamination was already present on the mirrors at XRCF and that the correction applied to the CALDB3.4 version of the HRMA effective area over-corrected the effect of the contamination. This problem was corrected in CALDB 4.1.1. During XRCF testing, shutters were used to calibrate each of the four mirror shells independently. CALDB 4.1.1 contains a model with the XRCF measured depths for the contaminant on each shell.
As a consequence, the change in the reflectivity above 2 keV produced lower hard band temperatures. We found in the current work that compared to XMM-Newton pn values, the ACIS temperatures obtained with the CALDB 4.1.1 agreed within a few per cent (see Figs. 18 and 19). Also, the soft and hard band fluxes increased by ~9% and ~4%, respectively.
13.0.3. CALDB 4.2.0
ACIS observations of astronomical sources as well as its own external calibration source (ECS) have shown that molecular contamination has been building up on the optical/UV blocking filters since launch. A new version (N0005) of the ACIS contamination model was released in CALDB 4.2.0. The previous version of the ACIS contamination model provided a good fit to the ECS data up until about 2006. For more recent observations, the previous version underestimated the optical depth of the contaminant on the ACIS filters. The new version released in CALDB 4.2 produces a much better agreement with the ECS data for recent observations.
We found that this revision mostly affected the cluster soft band fluxes, and produced consistency with the pn, while the soft band temperatures did not change appreciably (see Fig. 19)
14. Conclusions
We performed an X-ray spectral analysis of clusters of galaxies using data obtained with the XMM-Newton EPIC instruments pn, MOS1 and MOS2 and Chandra ACIS-S and ACIS-I. We additionally used the published results obtained using BeppoSAX MECS (deGrandi & Molendi 2002). We compared the derived temperatures and fluxes for each cluster based on the current instrument calibrations as of December 2009. The results are summarised in Fig. 20 and Table 11.
We found that there are no systematic differences in the temperatures obtained by fitting the 2−7 keV energy band of ACIS and EPIC (2−10 keV for MECS). These values are also consistent with those obtained by the EPIC temperature measurements based on the Fe XXV/XXVI line ratio. This shows that the energy dependence of the effective area in this band is accurately modelled in the studied instruments. Thus, the IACHEC cluster sample in the studied radial range (~0.1−0.3 r500) constitutes a set of standard candles for the calibration of the energy dependence of the hard band effective area. On the other hand, the disagreements at 6−25σ level on the hard band fluxes showed that there are systematic calibration uncertainties in the normalisations of the effective areas by 5−10% in the 2−7 keV band.
The temperatures obtained by fitting the soft band (0.5−2.0 keV) data of the pn and ACIS differ systematically and significantly, by ~18% (i.e. at 8.6σ level) on average. This indicates remaining uncertainties with the calibration of the energy dependence of the effective area in the 0.5−2.0 keV band in one or all instruments. Comparison of the residuals showed that the relative pn/ACIS cross-calibration bias is approximately a linear function of energy in the 0.5−2.0 keV band, amounting to a variation of 10% in this band. The uncertainties of the calibration and the modelling of the cluster emission in the soft band cannot be simultaneously resolved by using clusters of galaxies alone.
![]() |
Fig. 20 The average relative difference (diamonds) ± the error of the mean of the fluxes (solid line) and temperatures (dotted line) for different instrument pairs in the soft band (left side of the plot) and in the hard band (right side of the plot). |
The relative difference and its significance of temperatures and fluxes for different combinations of instruments and methods.
We evaluated the systematic effects on the Fe XXV/XXVI line ratio temperature measurement due to uncertainties of the implemented EPIC calibration of the energy scale and energy resolution and redistribution and the details of the line ratio modeling. The effect on the measured temperature is ~4%. The temperatures measured using the continuum shape and the Fe XXV/XXVI line ratio agree very accurately. This indicates that the deviations from the ionisation equilibrium state and Maxwellian electron velocity distribution are negligible in the studied regions of this cluster sample. Since the Fe XXV/XXVI line ratio measurement is not sensitive to smooth changes in the calibration of the effective area, it could be a powerful hard band calibration tool in future X-ray missions.
After the submission of this paper, an update of the pn redistribution matrix was released to the public in July 2010 (Haberl et al. 2010). The updated pn redistribution matrix may improve the Fe XXV/XXVI emission line modeling. We will address this issue in a follow-up paper. The updated pn calibration, however, will have little effect on the derived fluxes and continuum temperatures, because the line emission is weak compared to the continuum flux for the clusters in our sample. A study of sources observed by XMM-Newton with a wide range of spectral shapes shows that the change of the pn/MOS flux ratio above 0.5 keV between the new pn redistribution matrix and that used in the present paper is only 3% at most (Stuhlinger et al. 2010, in prep.). Thus, the discrepancy in the cluster fluxes between the pn and MOS is not resolved with the new pn redistribution matrix released in July 2010.
For the additional constrain for rin, arising from the PSF, see Sect. 6.3.
Acknowledgments
The work is based on observations obtained with XMM-Newton , an ESA science mission with instruments and contributions directly funded by ESA Member States and NASA. This research has made use of data and software provided by the Chandra X-ray Center (CXC). J.N. is supported by the Academy of Finland. We thank M. Bonamente, S. Molendi, P. Plucinsky and M. Smith for help and useful comments. We thank the IACHEC team for support.
References
- Anders E., & Grevesse, N. 1989, Geochim. Cosmochim. Acta, 53, 197 [Google Scholar]
- Akahori, T., & Yoshikawa, K., 2010, PASJ, 62, 335 [NASA ADS] [Google Scholar]
- Balucinska-Church, M., & McCammon, D., 1992, ApJ, 400, 699 [NASA ADS] [CrossRef] [Google Scholar]
- Betoya-Nonesa, J., Fukazawa, Y., Ohsugi, T. 2006, PASJ, 58, 103 [NASA ADS] [Google Scholar]
- Blanton, E., Sarazin, C., & McNamara, B. 2003, ApJ, 585, 227 [NASA ADS] [CrossRef] [Google Scholar]
- Briel, U., Henry, P., & Böhringer, H. 1992, A&A, 259, L31 [NASA ADS] [Google Scholar]
- David, L., & Nevalainen, J. 2009, A comparison of cluster temperatures derived from Chandra and XMM-Newton , Proceedings of the 2009 Chandra calibration review, http://cxc.harvard.edu/ccr/proceedings/2009/presentations/david/ [Google Scholar]
- David, L., Nevalainen, J., Bonamente, M., et al. 2007, XMM-Newton /Chandra cross calibration with clusters of galaxies, Proceedings of the Chandra 2007 calibration workshop, http://cxc.harvard.edu/ccw/proceedings/07_proc/presentations/david/ [Google Scholar]
- De Grandi, S., & Molendi, S. 2002, ApJ, 567, 163 [NASA ADS] [CrossRef] [Google Scholar]
- Durret, F., Kaastra, J., Nevalainen, J., et al. 2008, SSRv, 134, 51 [Google Scholar]
- Ghizzardi, S. 2002, In-flight calibration of the PSF for the pn camera, EPIC-MCT-TN-012, http://xmm.vilspa.esa.es/docs/documents/CAL-TN-0029-1-0.ps.gz [Google Scholar]
- Guainazzi, M. 2010, XMM-EPIC status of calibration and data analysis, XMM-SOC-CAL-TN-0018, http://xmm.vilspa.esa.es/docs/documents/CAL-TN-0018.pdf [Google Scholar]
- Guainazzi, M., Bianchi, S., Matt, G., et al. 2010, MNRAS, 406, 2013 [NASA ADS] [Google Scholar]
- Grevesse, N., & Sauval, A., 1998, SSRv, 85, 161 [Google Scholar]
- Haberl, F., Saxton, R., Guaibazzi, M., et al. 2010, Refinement of pn redistribution, XMM-CCF-REL-266 http://xmm2.esac.esa.int/docs/documents/CAL-SRN-0266-1-3.ps.gz [Google Scholar]
- Kaastra, J. 1992, An X-Ray Spectral Code for Optically Thin Plasmas (Internal SRON-Leiden Report, updated version 2.0) [Google Scholar]
- Kaastra, J., Bykov, A., & Werner, N. 2009, A&A, 503, 373 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
- Kalberla, P., Burton, W., Hartmann, D., et al. 2005, A&A, 440, 775 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
- Kotov, O., & Vikhlinin, A. 2005, ApJ, 633, 781 [NASA ADS] [CrossRef] [Google Scholar]
- Lodders, K. 2003, ApJ, 591, 1220 [NASA ADS] [CrossRef] [Google Scholar]
- Markevitch, M., Bautz, M., Biller, B., et al. 2003, ApJ, 583, 70 [NASA ADS] [CrossRef] [Google Scholar]
- Mateos, S., Saxton, R., Read, A., et al. 2009, A&A, 496, 879 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
- Mazzotta, P., Rasia, E., Moscardini, L., et al. 2004, MNRAS, 354, 10 [NASA ADS] [CrossRef] [Google Scholar]
- Nevalainen, J., Markevitch, M., & Lumb, D. 2005, ApJ, 629, 172 [NASA ADS] [CrossRef] [Google Scholar]
- Nevalainen, J., David, L., Bonamente, M., et al. 2007, IACHEC standard candles: clusters, Newsletter #1 of the International Astronomical Consrotium for High Energy Calibration, http://www.iachec.org/newsletter_clusters.pdf [Google Scholar]
- Prokhorov, D. 2010, A&A, 509, 29 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
- Prokhorov, D., Durret, F., Dogiel, V., et al. 2009, A&A, 496, 25 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
- Rephaeli, Y., Nevalainen, J., Ohashi, T., et al. 2008, SSRv, 134, 71 [Google Scholar]
- Sarazin, C. 1988, X-ray emissions from clusters of galaxies (Cambridge Astrophys. Ser.) [Google Scholar]
- Smith, R., Brickhouse, N., Liedahl, D., et al. 2001, ApJ, 556L, 91 [NASA ADS] [CrossRef] [Google Scholar]
- Snowden, S., Mushotzky, R., Kuntz, K., et al. 2008, A&A, 478, 615 [NASA ADS] [CrossRef] [EDP Sciences] [Google Scholar]
- Stuhlinger, M., Kirsch, M., Santos-Lleo, et al. 2008, XMM-SOC-CAL-TN-0052, http://xmm.vilspa.esa.es/docs/documents/CAL-TN-0052.ps.gz [Google Scholar]
- Vikhlinin, A., Markevitch, M., Murray, S., et al. 2005, ApJ, 628, 655 [NASA ADS] [CrossRef] [Google Scholar]
- Vikhlinin, A., Kravtsov, A., Forman, W., et al. 2006, ApJ, 640, 691 [NASA ADS] [CrossRef] [Google Scholar]
Appendix A: Spectral fits
We show here the data and the best-fit single-temperature MEKAL models in the hard and soft bands for pn (Figs. A.1 and A.2) and for ACIS (Figs. A.3 and A.4) used for the pn/ACIS temperature and flux comparison. The spectral parameters of the pn and ACIS fits in all bands are shown in Table A.1.
Best-fit temperatures and metal abundances for pn and ACIS in different bands.
![]() |
Fig. A.1 The hard band pn spectra (crosses) and the best-fit single-temperature fits (solid lines) for the cluster sample. The normalisation of the spectra is adjusted for plot clarity and does not correctly reflect the relative brightness of the clusters. |
![]() |
Fig. A.2 The soft band pn spectra (crosses) and the best-fit single-temperature fits (solid lines) for the cluster sample. The normalisation of the spectra is adjusted for plot clarity and does not correctly reflect the relative brightness of the clusters. |
![]() |
Fig. A.3 The hard band ACIS spectral data (crosses) and the best-fit single-temperature fits (lines) for the cluster sample. The normalisation of the spectra is adjusted for plot clarity and does not reflect correctly the relative brightness of the clusters. The spectra for A85 and Coma were obtained from several CCD chips and were fitted simultaneously. |
![]() |
Fig. A.4 The soft band ACIS spectra (crosses) and the best-fit single-temperature fits (solid lines) for the cluster sample. The normalisation of the spectra is adjusted for plot clarity and does not correctly reflect the relative brightness of the clusters. The spectra for A85 and Coma were obtained from several CCD chips and were fitted simultaneously. |
Appendix B: Systematic uncertainties affecting the Fe XXV/XXVI line ratio measurement using XMM-Newton EPIC instruments
B.1. Effective area
B.1.1. Break in the effective area
The virtue of the Fe XXV/XXVI line ratio method is that the energies of the two lines only differ by ~ 300 eV. If there was a sudden change in the real effective area, co-incidentally at an energy between those of the FeXXV and FeXXVI line energies, that was not correctly implemented into the calibration, then the measured line ratio would be inaccurate. However, the redshifts in our sample vary from 0.0231 to 0.0773 which produce a ~ 300 eV variation in the Fe line energies in different clusters. Thus, a possible break in the effective area at a fixed energy cannot produce a systematic effect in the sample, but can affect some of the clusters. To estimate the effect of this unlikely situation, we simulated a pn spectrum of a cluster with T = 9 keV and metal abundance of 0.3 Solar at a redshift z = 0. When fitting the simulated data in a 6.45−7.25 keV band, we introduced a 10% drop in the effective area in the associated auxiliary response file at E ≥ 6.85 keV. In order to produce the data above 6.85 keV, the model Fe XXVI flux increases, i.e. the temperature increased to 10.4 keV, which is 15% higher than the input value.
B.1.2. Smooth calibration bias
We note that we found an excellent agreement between the hard band temperatures obtained with different instruments (see Sect. 7). Because the different instruments are calibrated based on a combination of ground measurements and in-flight measurements of different types of celestial sources, it would be a highly unlikely co-incidence that all the instruments have similar uncertainties in the calibration as to yield similarly biased temperatures. This hypothetical bias should be a smooth function of energy in order for the biased model to agree well with the data, as observed. We examined the sensitivity of the Fe XXV/XXVI line ratio temperature measurement to a smooth hard band calibration bias using simulated data. We created spectra with kT in the range 4−10 keV. We kept the metal abundance at 0.3 Solar and the redshift at 0. We used 107 counts in the 6.45−7.25 keV energy band in order to eliminate the statistical effects. We used the auxiliary response file of A1795 for the simulations.
When fitting the simulated data, we approximated the effect of a smooth calibration bias by modifying the auxiliary file we used for the simulations. In detail, we multiplied the effective area column with a linear function which has a value of 1.0 at 1 keV, and varies between 0.8 and 1.2 at 10 keV. Thus the effective area is unchanged at 1 keV, but is underestimated or overestimated by a maximum of 20% at 10 keV.
We found that the resulting relative bias in the temperature measurement is higher for the higher input temperatures, due to their higher statistical weight in the more biased high energy band (see Fig. B.1). However, the effect in the Fe XXV/XXVI temperature measurement was very small: even if the effective area was off by 15% at photon energies of 10 keV, the best-fit Fe XXV/XXVI temperature would be biased by less than 1% (see Fig. B.1). The reason for this is that even though the effective area is over- or underpredicted by up to ~ 15% in the 6−7 keV band in average, the relative change of the effective area between the 6.45 and 7.25 keV is only ~ 1%. Thus the only effect is a biased MEKAL normalisation up to ± ~ 10%, while the shape of the spectrum does not change.
The situation is the opposite in the 2.0−7.0 keV band. The varying degree of calibration bias in a 10−20% range does not much affect the derived emission measures (which only vary by ~ 1%). However, it does affect the measured continuum shape, yielding a 10−20% bias in the temperature (see Fig. B.1).
![]() |
Fig. B.1 The temperature bias in the simulated spectra as a function of the fraction of the linear bias in the effective area at 10 keV for the 2.0−7.0 keV band fits (dotted lines) and for the ~ 6−7 keV band fit (dashed lines). The different dotted lines denote different input temperatures from 4 to 10 keV (higher temperatures yield higher bias). For the ~ 6−7 keV band fit only the curves for kT = 10 keV are shown for clarity. The lines in the upper half (lower half) correspond to positive (negative) bias in the effective area. |
B.1.3. ACIS calibration changes
We further tested the effects of smooth effective area calibration changes on the Fe XXV/XXVI line ratio measurement by a comparison of ACIS temperatures derived using calibration versions CALDB 3.4 and CALDB 4.2.0. Note that the substantial, smooth changes in the ACIS effective area calibration between these two versions resulted in significant changes in the hard and soft band temperatures (see Sects. 7 and 9). We relaxed the requirement for the minimum number of counts to 400 since the bias due to the limited number of counts (see Sect. 8.1) does not depend on the calibration version and thus will not introduce a systematic difference.
We fitted the data in the ~ 6−7 keV energy band allowing the emission measure to be a free parameter. We found that the Fe XXV/XXVI best-fit temperatures obtained with CALDB 3.4 and CALDB 4.2 are nearly identical (see Fig. B.2). This result supports the above suggestion that the Fe XXV/XXVI line ratio temperature is rather insensitive to smooth changes in the calibration of the effective area.
![]() |
Fig. B.2 The best-fit temperatures obtained from ACIS data in the ~ 6−7 keV energy band using calibration versions CALDB 3.4 v.s CALDB4.2.0. |
B.2. Accuracy of the energy resolution and redistribution calibration
We examined how robust our Fe XXV/XXVI temperature measurements are when considering possible uncertainties in modelling of the time-dependent energy resolution and redistribution of the pn and MOS (Guainazzi 2010). Following the work of Molendi et al. (2009), we added a multiplicative “gsmooth” component to the model, which convolves the input model with a Gaussian kernel. We first fitted each cluster individually. This yielded rather large statistical uncertainties for the width of the Gaussian kernel ( ≡ σ) within which the clusters are rather consistent. On average, the value for σ is 26 eV, and the rms scatter is 20 eV. Thus, within the scatter, these results are roughly consistent with the Gaussian width of 4 eV reported by Molendi et al. (2009) for Perseus.
However, the cluster observations of our sample were performed in a short period, early in the XMM-Newton mission (during years 2000−2002) when the energy resolution was stable (e.g. Guainazzi 2010). We thus experimented by simultaneously fitting the spectra of all clusters including the gsmooth-component, while forcing σ to be equal in all data sets. For χ2-comparison, we also repeated the fit without the gsmooth-component. We found that the addition of the gsmooth-component improved the fit significantly: χ2 decreased from 297.0 to 285.9 while the number of free parameters increased from 18 to 19 while using 345 spectral bins. The fit obtains a value of 35 ± 7 eV for the Gaussian width, i.e. consistent with that obtained when fitting each cluster individually above. This value is consistent with measurements of the on-board pn calibration source (see, e.g., Guainazzi et al. 2010). Thus, our results indicate a systematic underestimation of the pn resolution in the response matrix used in this paper. A similar exercise to our MOS data yielded a Gaussian width consistent with zero, i.e. this effect is not apparent in MOS (consistent with Guainazzi et al. 2010). Thus this is not a physical broadening effect of the lines, but rather an instrumental problem of the pn.
The pn temperatures decreased systematically with the inclusion of the gsmooth-component, by 2% on average. This is slightly smaller than the value obtained when fitting each cluster individually. Thus we conclude that the effect of the uncertainties in the calibration of the energy resolution and redistribution at ~6−7 keV render the measured Fe XXV/XXVI pn temperatures too high by ~2%.
B.3. Calibration of the energy scale
We then examined how possible problems in the calibration of the energy scale in the ~6−7 keV band impact the Fe XXV/XXVI temperature measurements. There are two principal factors affecting the energy reconstruction of an event, namely Charge Transfer Inefficiency (CTI) and gain. CTI describes the transfer of charge as it is transported through the CCD to the output amplifiers during read-out. Gain is the conversion of the charge signal deposited by a detected photon from charge into energy (Guainazzi 2010). Note that possible uncertainties in the redshift measurement using the spectra of the galaxies of a given cluster (NASA Extragalactic Database) may contribute to the uncertainty of the energy scale because we keep the redshift fixed in the fits.
In order to examine the above effects, we used the “gain fit” option in XSPEC 11.3.2.ag package to modify the definition of the channel energies in the response matrix with an offset that does not depend on the energy. We fitted each cluster individually and found that in average the offset parameter obtained values of 5 eV and 16 for the pn and MOS, respectively. Considering the rms scatter, these values are consistent with the nominal accuracies of energy reconstruction of 10 eV and 5 eV for the pn and MOS, respectively, in the full energy range (Guainazzi 2010).
The modification of the gain offset renders the temperatures systematically lower, by 1% (3%) for the pn (MOS) on average. Thus, we conclude that the uncertainties in the calibration of the energy scale of the EPIC instruments combined with the possible uncertainties of the cluster redshift measurements render the measured Fe XXV/XXVI EPIC temperatures too high by ~1−3%.
B.4. Details of the emission model
In addition to the MEKAL model we adopted for the emission modelling, there also exists a commonly used emission model APEC (Smith et al. 2001). Differences on the details of the modelling of electron transitions may affect the interpreted temperature for a given line ratio data. We examined this by fitting the ~6−7 keV band pn data using either MEKAL or APEC model. We found that the temperatures derived with APEC model are systematically lower than those obtained with the MEKAL model, by 2% on average.
We also experimented with the choise of the element abundance tables by replacing our adopted one(Grevesse & Sauval 1998) with that of Anders & Grevesse (1989) or Lodders (2003). The differences in the derived ~6−7 keV band temperatures are smaller than 0.1%.
All Tables
Best-fit temperatures and statistical uncertainties for the EPIC instruments in the ~6−7 keV band.
The fluxes in the hard band (2−7 keV) given by the best-fit single-temperature MEKAL model.
The relative difference and its significance of temperatures and fluxes for different combinations of instruments and methods.
All Figures
![]() |
Fig. 1 The solid lines show the average 3D temperature profiles from Vikhlinin et al. (2006) for each cool core cluster in our sample. The models are plotted as a function of the 3D radius in units of r500, starting from the radii corresponding to rin when projected to the plane of the sky, extending to rout used for extracting the pn/MOS spectra. The solid vertical bars indicate rout used for extracting the spectra for EPIC/ACIS comparison. The dashed vertical lines denote the approximately isothermal region of 0.1−0.3 r500. |
In the text |
![]() |
Fig. 2 The upper panels show the best-fit temperatures (asterisks) and the 1σ uncertainties (boxes) in the hard band obtained with the XMM-Newton instruments pn (left panel), MOS1 (middle panel) and MOS2 (right panel). The lower panels show the relative temperature difference, fT = ΔT / ⟨ T ⟩ (diamonds), and its 1σ uncertainty for MOS1-pn (left panel), MOS2-pn (middle panel) and MOS2-MOS1 (right panel). The dotted and dashed lines show the weighted mean of fT ± the error of the mean. |
In the text |
![]() |
Fig. 3 The best-fit temperatures (asterisks) and the 1σ uncertainties (boxes) in the hard band obtained with the pn vs. those obtained with MOS (i.e. combined MOS1 and MOS2 spectra). |
In the text |
![]() |
Fig. 4 The upper panel shows the best-fit temperatures (asterisks) and 1σ uncertainties (boxes) in the hard band obtained with the XMM-Newton pn and BeppoSAX MECS instruments. The lower panel shows the relative MECS-pn temperature difference, fT = ΔT / ⟨ T ⟩ (diamonds), and its 1σ uncertainty. The dotted and dashed lines show the weighted mean of fT ± the error of the mean. |
In the text |
![]() |
Fig. 5 The best-fit temperatures (asterisks) and the 1σ uncertainties (boxes) in the hard band obtained with the XMM-Newton pn detector vs. those obtained with the Chandra ACIS detector using CALDB 4.2.0. |
In the text |
![]() |
Fig. 6 The relative bias of the temperature derived by fitting the simulated spectra in the 6.45−7.25 keV band as a function of the number of counts for the input values kT = 5−7 keV (dotted blue lines) and for kT = 8−10 keV (solid lines). The dash-dot line shows the allowed upper limit of 2% for the bias in the sample. |
In the text |
![]() |
Fig. 7 The best-fit MEKAL models (solid line) in the ~6−7 keV band data which contain the Fe XXV and Fe XXVI emission lines and statistical uncertainties (crosses). The pn (left panel) and MOS (right panel) data and the models are arbitrarily scaled for the clarity of the display. |
In the text |
![]() |
Fig. 8 The 2-parameter confidence contours at 1σ for A2029 obtained with the MEKAL fits to the pn data in the ~6−7 keV band. |
In the text |
![]() |
Fig. 9 The best-fit temperatures (asterisks) obtained with the MEKAL fits in the ~6−7 keV band data of the pn vs. those obtained with MOS. The solid boxes indicate the statistical uncertainties at 1σ level while the dotted boxes include the systematic uncertainties. |
In the text |
![]() |
Fig. 10 The upper panels show the best-fit temperatures (asterisks) and 1σ uncertainties (boxes) for the Fe XXV/XXVI line ratio temperatures vs. the 2−6 keV band continuum for the pn (left panel) and MOS (right panel). The lower panels show the relative temperature difference fT (i.e. the 2−6 keV band continuum temperature minus the Fe XXV/XXVI line ratio temperature, divided by the mean of the two) and its 1σ uncertainty for the pn (left panel) and MOS (right panel). The dotted and dashed lines show the weighted mean of fT ± the error of the mean. |
In the text |
![]() |
Fig. 11 The upper panels show the best-fit temperatures (asterisks) and statistical 1σ uncertainties (boxes) in the soft band with the XMM-Newton instruments pn/MOS1 (left panel), pn/MOS2 (middle panel) and MOS1/MOS2 (right panel). The lower panels show the relative temperature difference fT (=ΔT/⟨ T ⟩, diamonds) and its 1σ uncertainty for MOS1-pn (left panel), MOS2-pn (middle panel) and MOS2-MOS1 (right panel). The dotted and dashed lines show the weighted mean of fT ± the error of the mean. |
In the text |
![]() |
Fig. 12 The upper panels show the best-fit temperatures (asterisks) and 1σ uncertainties (boxes) in the soft band for the pn and ACIS (left panel) and in the hard and soft bands for ACIS (right panel). The lower panels show the relative temperature difference, fT = ΔT / ⟨ T ⟩ (diamonds) and its statistical 1σ uncertainty for ACIS soft band – pn soft band (left panel) and ACIS soft band – ACIS hard band (right panel). The dotted and dashed lines show the weighted mean of fT ± the error of the mean. |
In the text |
![]() |
Fig. 13 The ratio of the ACIS data to the pn model prediction using the best-fit pn model and the ACIS responses. The model has been normalised so that the ratio equals unity at 2.0 keV. The dashed line shows the best-fit linear relation. |
In the text |
![]() |
Fig. 14 The upper panels show the best-fit temperatures (asterisks) and 1σ uncertainties (boxes) in the wide band using pn or ACIS data. The lower panel shows the relative ACIS-pn temperature difference fT (=ΔT/⟨ T ⟩, diamonds) and its statistical 1σ uncertainty. The dotted and dashed lines show the weighted mean of fT ± the error of the mean. |
In the text |
![]() |
Fig. 15 The upper panels show the best-fit temperatures (asterisks) and statistical 1σ uncertainties (boxes) in the soft and hard bands for XMM-Newton instruments pn (left panel), MOS1 (middle panel) and MOS2 (right panel). The lower panels show the relative soft-hard temperature difference fT (=ΔT / ⟨ T ⟩, diamonds) and its statistical 1σ uncertainty for pn (left panel), MOS1 (middle panel) and MOS2 (right panel). The dotted and dashed lines show the weighted mean of fT ± the error of the mean. |
In the text |
![]() |
Fig. 16 The relative flux difference, fF = ΔF / ⟨ F ⟩ (diamonds) and its statistical uncertainties in the hard band (upper row) and in the soft band (lower row) are shown as a function of pn hard band temperature for different instrument pairs. The dotted and dashed lines show the weighted mean of fF ± the error of the mean. |
In the text |
![]() |
Fig. 17 The relative flux difference, fF = ΔF/ ⟨ F ⟩ (diamonds) and its statistical uncertainties between ACIS and pn in the soft band (left panel) and the hard band (right panel) are plotted against the pn hard band temperature. The dotted and dashed lines show the weighted mean of fF ± the error of the mean. |
In the text |
![]() |
Fig. 18 The upper panels show the best-fit temperatures (asterisks) in the hard band obtained with XMM-Newton pn vs. those obtained with Chandra ACIS using CALDB 3.4 (left panel), CALDB 4.1.1 (middle panel) and CALDB 4.2 (right panel). The lower panels show the relative ACIS-pn temperature difference, fT = ΔT / ⟨ T ⟩ (diamonds) and its 1σ uncertainty. The dotted and dashed lines show the weighted mean of fF ± the error of the mean. |
In the text |
![]() |
Fig. 19 The relative differences of the soft and hard band temperatures (two upper rows) and fluxes (two lower rows) between the pn and ACIS at different stages of ACIS calibration (different columns). The values are shown as a function of the hard band pn temperatures. Note that the scaling of the y-axis is different in different rows. The average values are marked with a dotted line. |
In the text |
![]() |
Fig. 20 The average relative difference (diamonds) ± the error of the mean of the fluxes (solid line) and temperatures (dotted line) for different instrument pairs in the soft band (left side of the plot) and in the hard band (right side of the plot). |
In the text |
![]() |
Fig. A.1 The hard band pn spectra (crosses) and the best-fit single-temperature fits (solid lines) for the cluster sample. The normalisation of the spectra is adjusted for plot clarity and does not correctly reflect the relative brightness of the clusters. |
In the text |
![]() |
Fig. A.2 The soft band pn spectra (crosses) and the best-fit single-temperature fits (solid lines) for the cluster sample. The normalisation of the spectra is adjusted for plot clarity and does not correctly reflect the relative brightness of the clusters. |
In the text |
![]() |
Fig. A.3 The hard band ACIS spectral data (crosses) and the best-fit single-temperature fits (lines) for the cluster sample. The normalisation of the spectra is adjusted for plot clarity and does not reflect correctly the relative brightness of the clusters. The spectra for A85 and Coma were obtained from several CCD chips and were fitted simultaneously. |
In the text |
![]() |
Fig. A.4 The soft band ACIS spectra (crosses) and the best-fit single-temperature fits (solid lines) for the cluster sample. The normalisation of the spectra is adjusted for plot clarity and does not correctly reflect the relative brightness of the clusters. The spectra for A85 and Coma were obtained from several CCD chips and were fitted simultaneously. |
In the text |
![]() |
Fig. B.1 The temperature bias in the simulated spectra as a function of the fraction of the linear bias in the effective area at 10 keV for the 2.0−7.0 keV band fits (dotted lines) and for the ~ 6−7 keV band fit (dashed lines). The different dotted lines denote different input temperatures from 4 to 10 keV (higher temperatures yield higher bias). For the ~ 6−7 keV band fit only the curves for kT = 10 keV are shown for clarity. The lines in the upper half (lower half) correspond to positive (negative) bias in the effective area. |
In the text |
![]() |
Fig. B.2 The best-fit temperatures obtained from ACIS data in the ~ 6−7 keV energy band using calibration versions CALDB 3.4 v.s CALDB4.2.0. |
In the text |
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.