Free Access

 

 

Table 3:

List of Si, Ca, Fe, and Ba spectral lines used for reconstruction of chemical stratification.

Ion
$\lambda$ (Å) $E_{\rm i}$ (eV) $\log(gf)$ $\log~\gamma_{\rm St}$ Ref.
Si I 5517.533 5.082 -2.49  -4.46 solar
Si I 5690.425 4.930 -1.76  -4.57 NIST
Si I 5797.688 5.614 -2.67  -3.86 K07
Si I 5797.856 4.954 -2.05  -4.32 NIST
Si I 6087.697 5.871 -2.38  approx K07
Si I 6087.805 5.871 -1.71  approx solar
Si I 6155.134 5.619 -0.80  -3.70 solar
Si II 6347.109 8.121  0.297 -5.04 BBCB
Si II 6371.371 8.121 -0.003 -5.04 BBCB
Si I 8742.446 5.871 -0.510 -4.52 solar
Si I 8892.720 5.984 -0.830 -4.37 solar
Ca I 6717.681 2.709 -0.524 -4.90 SR
Ca I 7148.150 2.709  0.137 -6.01 SR
Ca I 7326.145 2.933 -0.208 -5.16 S
Ca II 8254.721 7.515 -0.398 -4.60 T
Ca II 8498.223 1.692 -1.416 -5.70 T
Ca II 8912.068 7.047  0.637 -5.10 T
Fe I 4404.750 1.557 -0.142 -6.20 MFW
Fe II 5169.033 2.891 -1.14  -6.59 M
Fe I 5405.775 0.990 -1.844 -6.30 MFW
Fe I 5415.199 4.386  0.642 -4.76 BWL
Fe I 5615.644 3.332  0.050 -5.50 BKK
Fe I 6219.281 2.198 -2.433 -6.20 MFW
Fe II 7222.394 3.889 -3.36  -6.67 HLGH
Fe I 8248.129 4.371 -0.887 -5.36 K07
Fe I 8365.634 3.251 -2.047 -6.10 BK
Fe I 8945.189 5.033 -0.235 -5.17 K07
Ba I 5777.618 1.676  0.72  approx MW
Ba II 5853.668 0.604 -1.00  -6.35 MW
Ba I 6019.465 1.120 -0.10  approx MW
Ba I 6063.109 1.143  0.21  approx MW
Ba II 6141.713 0.704 -0.076 -6.35 MW
Ba II 6496.897 0.604 -0.377 -6.35 MW
Ba I 7059.938 1.190  0.68  approx MW
Ba I 7280.297 1.143  0.47  approx MW

References. Columns give the ion identification, central wavelength, excitation potential, oscillator strength ($\log(gf)$) and the Stark damping constant ( $\log~\gamma_{\rm St}$) for T=10 000 K. The last column gives reference for the adopted oscillator strength: NIST - Ralchenko et al. (2009); K07 - Kurucz (2007); BBCB - Berry et al. (1971); SR - Smith & Raggett (1981); S - Smith (1988); T - Theodosiou (1989); MFW - Martin et al. (1988); BWL - O'Brian et al. (1991); BKK - Bard et al. (1991); HLGH - Hannaford et al. (1982); BK - Bard & Kock (1994); MW - Miles & Wiese (1969).


Source LaTeX | All tables | In the text

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.