Summary of coronagraphic results and comparison with theory.
Metrics Measured on bench Theory
  $\Delta \lambda / \lambda [\%] $
  1.4 20 1.4 20
Contrast at 3$\lambda/D$ $5.0 \times 10^{-5}$ $1.5 \times 10^{-4}$ $1.4 \times 10^{-6}$ $1.2 \times 10^{-5}$
Contrast at 12$\lambda/D$ $2.3 \times 10^{-6}$ $3.5 \times 10^{-6}$ $2.1 \times 10^{-7}$ $2.8 \times 10^{-7}$
Contrast at 20$\lambda/D$ $1.2 \times 10^{-6}$ $1.8 \times 10^{-6}$ $1.0 \times 10^{-7}$ $1.3 \times 10^{-7}$
Total rejection 489 355 1000 641
Peak rejection 627 674 1058 788