JWST/MIRI coronagraphic performances as measured on-sky
1
LESIA, Observatoire de Paris, Université PSL, CNRS, Sorbonne Université, Université de Paris Cité,
5 place Jules Janssen,
92195
Meudon, France
e-mail: Anthony.boccaletti@obspm.fr
2
Université Paris-Saclay, Université Paris Cité, CEA, CNRS, AIM,
91191
Gif-sur-Yvette, France
3
UKATC, The Royal Observatory,
Blackford Hill,
Edinburgh,
EH9 3HJ, Scotland
4
Institute for Astronomy, University of Edinburgh, Royal Observatory,
Blackford Hill,
Edinburgh
EH9 3HJ, Scotland
5
Space Telescope Science Institute,
3700 San Martin Dr,
Baltimore, Maryland
21218, USA
6
Max-Planck-Institut für Astronomie (MPIA),
Königstuhl 17,
69117
Heidelberg, Germany
7
Steward Observatory and the Department of Astronomy, The University of Arizona,
933 N Cherry Ave,
Tucson, AZ,
85721, USA
8
Telespazio UK for the European Space Agency, ESAC,
Camino Bajo del Castillo s/n,
28692
Villanueva de la Canada, Spain
9
Centro de Astrobiología (CSIC-INTA), Carretera de Ajalvir,
28850
Torrejón de Ardoz, Madrid, Spain
10
NASA Goddard Space Flight Center, Exoplanets & Stellar Astrophysics Laboratory,
Code 667,
Greenbelt, MD
20771, USA
11
European Space Agency,
3700 San Martin Drive,
Baltimore,
MD21218, USA
Received:
22
July
2022
Accepted:
5
September
2022
Context. Characterization of directly imaged exoplanets is one of the most eagerly anticipated science functions of the James Webb Space Telescope. MIRI, the mid-IR instrument, has the capability to provide unique spatially resolved photometric data points in a spectral range never before achieved for such objects.
Aims. We aim to present the very first on-sky contrast measurements of the MIRI coronagraphs. In addition to a classical Lyot coronagraph at the longest wavelength, this observing mode implements the concept of the four-quadrant phase mask for the very first time in a space telescope.
Methods. We observed single stars together with a series of reference stars to measure raw contrasts as they are delivered on the detector, as well as reference-subtracted contrasts.
Results. The MIRI coronagraphs achieve raw contrasts better than 10−3 at the smallest angular separations (within 1″) and about 10−5 farther out (beyond 5 ~ 6″). Subtracting the residual diffracted light left behind the coronagraph has the potential to bring the final contrast down to the background- and detector-limited noise floor at most angular separations (a few times 10−5 at less than 1″).
Conclusions. The MIRI coronagraphs behave as expected from simulations. In particular, the raw contrasts for all four coronagraphs are fully consistent with the diffractive model. Contrasts obtained by subtracting reference stars also meet expectations and are fully demonstrated for two four-quadrant phase masks (F1065C and F1140C). The worst contrast, measured at F1550C, is very likely due to a variation in the phase aberrations at the primary mirror during the observations, and not an issue with the coronagraph itself. We did not perform reference star subtraction with the Lyot mask at F2300C, but we anticipate that it would bring the contrast down to the noise floor.
Key words: instrumentation: high angular resolution / techniques: high angular resolution / techniques: image processing / planetary systems
© A. Boccaletti et al. 2022
Open Access article, published by EDP Sciences, under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
This article is published in open access under the Subscribe-to-Open model. Subscribe to A&A to support open access publication.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.