Ultra-sensitive THz microwave kinetic inductance detectors for future space telescopes
1
SRON - Netherlands Institute for Space Research,
Niels Bohrweg 4,
2333
CA - Leiden, The Netherlands
e-mail: J.Baselmans@sron.nl
2
THz Sensing group, Microelectronics Department, Delft University of Technology,
Mekelweg 1,
2628
CD - Delft, The Netherlands
Received:
22
April
2022
Accepted:
14
June
2022
Aims. Future actively cooled space-borne observatories for the far-infrared, loosely defined as a 1–10 THz band, can potentially reach a sensitivity limited only by background radiation from the Universe. This will result in an increase in observing speed of many orders of magnitude. A spectroscopic instrument on such an observatory requires large arrays of detectors with a sensitivity expressed as a noise equivalent power NEP = 3 × 10−20 W/√Hz.
Methods. We present the design, fabrication, and characterisation of microwave kinetic inductance detectors (MKIDs) for this frequency range reaching the required sensitivity. The devices are based on thin-film NbTiN resonators which use lens-antenna coupling to a submicron-width aluminium transmission line at the shorted end of the resonator where the radiation is absorbed. We optimised the MKID geometry for a low NEP by using a small aluminium volume of ≈1 µm3 and fabricating the aluminium section on a very thin (100 nm) SiN membrane. Both methods of optimisation also reduce the effect of excess noise by increasing the responsivity of the device, which is further increased by reducing the parasitic geometrical inductance of the resonator.
Results. We measure the sensitivity of eight MKIDs with respect to the power absorbed in the detector using a thermal calibration source filtered in a narrow band around 1.5 THz. We obtain a NEPexp(Pabs) = 3.1 ± 0.9 × 10−20 W/√Hz at a modulation frequency of 200 Hz averaged over all measured MKIDs. The NEP is limited by quasiparticle trapping.
Conclusions. The measured sensitivity is sufficient for spectroscopic observations from future, actively cooled space-based observatories. Moreover, the presented device design and assembly can be adapted for frequencies up to ≈10 THz and can be readily implemented in kilopixel arrays.
Key words: instrumentation: detectors / methods: miscellaneous
© J. J. A. Baselmans et al. 2022
Open Access article, published by EDP Sciences, under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
This article is published in open access under the Subscribe-to-Open model. Subscribe to A&A to support open access publication.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.