Open Access
Erratum
This article is an erratum for:
[https://doi.org/10.1051/0004-6361/202347317]


Table 1

Spectral measurements for detected sources.

Source Line TAdv${\mathop \smallint \nolimits^ ^}T_A^ * dv$ (K km s–1) TA (mK) rms (mK) Vsys (km s1) Vexp (km s1) FWHM (km s–1)
EY Hya 12CO (J=1–0) 1.12 ± 0.10 62 11 +24.6 10.1 14.7
EY Hya 12CO (J=2–1) 4.74 ± 0.07 290 7 +21.5 10.7 14.6
R Lmi 12CO (J=1–0) 2.42 ± 0.18 166 18 +1.7 6.4 11.6
R Lmi 12CO (J=2–1) 9.5 ± 0.2 740 20 +2.0 6.7 11.2
R Uma 12CO (J=1–0) <0.22 12
R Uma 12CO (J=2–1) 0.40 ± 0.09 50 9 +39.0 4.7 6.2
RR Eri 12CO (J=1–0) <0.72 15
RR Eri 12CO (J=2–1) 2.94 ± 0.09 171 9 –22.4 12.0 16.0
RT Cnc 12CO (J=1–0) <0.44 9
RT Cnc 12CO (J=2–1) 0.76 ± 0.08 47 8 +33.0 7.2 11.7
RU Her 12CO (J=1–0) 2.77 ± 0.05 187 5 –12.2 7.6 12.8
RU Her 12CO (J=2–1) 6.19 ± 0.06 422 6 –12.0 7.5 12.7
RW Boo 12CO (J=1–0) 1.29 ± 0.05 38 5 +5.1 17.3 20.3
3 7.7
RW Boo 12CO (J=2–1) 2.07 ± 0.06 54 6 +4.4 15.6 19.8
29 8.4
RZ Uma 12CO (J=1–0) <0.26 11
RZ Uma 12CO (J=2–1) 0.53 ± 0.10 66 10 –28.6 4.7 7.7
SV Peg 12CO (J=1–0) 7.48 ± 0.19 507 19 +5.3 7.3 12.5
SV Peg 12CO (J=2–1) 13.9 ±0.4 1120 40 +5.4 7.2 11.3
T Dra 12CO (J=1–0) 12.1 ± 0.2 490 20 –13.2 12.0 20.8
T Dra 12CO (J=2–1) 14.18 ± 0.10 639 10 –13.9 11.5 19.4
V Eri 12CO (J=1–0) 2.29 ± 0.17 53 17 –14.1 10.1 22.9
V Eri 12CO (J=2–1) 9.55 ± 0.11 393 11 –15.6 10.4 19.3
VY Uma 12CO (J=1–0) 2.52 ± 0.10 256 11 –1.2 6.7 8.5
VY Uma 12CO (J=2–1) 5.14 ± 0.10 579 10 –0.9 6.5 8.0
W Peg 12CO (J=1–0) 1.9 ± 0.3 80 30 –15.7 7.7 16.3
W Peg 12CO (J=2–1) 4.0 ± 0.7 370 70 –16.6 7.1 9.9
Y Crb 12CO (J=1–0) 0.15 ± 0.08 21 8 +6.9 3.1 6.0
Y Crb 12CO (J=2–1) 0.33 ± 0.15 58 16 +4.3 3.9 6.0
Z Cnc 12CO (J=1–0) <20 10
Z Cnc 12CO (J=2–1) 0.42 ± 0.08 55 8 –9.3 3.9 6.7

Notes. Column (1): source, Col. (2): transition, Col. (3): area of the observed line profil, Col. (4): antenna temperature at the central velocity of the fit to the line profile, Col. (5): noise, Col. (6): Systemic velocity (line centroid) in the local standard of rest (LSR) frame, Col. (7): expansion velocity of the shell fit, Col. (8): Full Width at a Half Maximum of the Gaussian fit.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.