Table 2
Column densities and isotope ratios derived for 12CO2 and 13CO2 ice.
Source | L(L⊙) | Distance (pc) | N 12CO2 2.70 µm | N 12CO2 4.27 µm | N 13CO2 4.39 µm | N 12CO2 15.2 µm | 12C/13C 2.70 µm | 12C/13C 4.27 µm | 12C/13C 15.2 µm |
---|---|---|---|---|---|---|---|---|---|
B1-b | 0.2 | 293 | – | – | 2.6 × 1016 | 2.6 × 1018 | – | – | 100 ± 46 |
TMC1-E | 0.7 | 142 | 1.0 × 1018 | 1.1 × 1018 | 1.6 × 1016 | 1.2 × 1018 | 62 ± 19 | 69 ± 18 | 75 ± 34 |
TMC1-W | 0.7 | 142 | 1.3 × 1018 | 9.0 × 1017 | 1.2 × 1016 | 1.2 × 1018 | 81 ± 25 | 58 ± 15 | 76 ± 35 |
B1-a-N | 1.5 | 293 | – | – | 2.2× 1016 | 2.1 × 1018 | – | – | 94 ± 43 |
B1-a-S | 1.5 | 293 | – | – | 1.9 × 1016 | 2.1 × 1018 | – | – | 114 ± 52 |
Per-emb55-a | 1.8 | 293 | 5.7 × 1017 | 5.7 1017 | 8.1 × 1015 | 6.0 × 1017 | 70 ± 21 | 70 ± 18 | 74 ± 34 |
Per-emb55-b | 1.8 | 293 | 5.8 × 1017 | 6.2 1017 | 7.7 × 1015 | 5.5 × 1017 | 74 ± 23 | 80 ± 21 | 70 ± 32 |
L1527 | 3.1 | 142 | – | – | 4.6 × 1016 | 4.8 × 1018 | – | – | 105 ± 48 |
B1-c | 3.2 | 293 | – | – | 7.1 × 1016 | 7.9 × 1018 | – | – | 112 ± 52 |
EDJ183-a | 3.2 | 293 | 5.7 × 1017 | 5.9 × 1017 | 7.0 × 1015 | 5.2 × 1017 | 81 ± 25 | 84 ± 22 | 74 ± 34 |
EDJ183-b | 3.2 | 293 | 5.8 × 1017 | 5.5 × 1017 | 5.8 × 1015 | 5.1 × 1017 | 99 ± 31 | 94 ± 25 | 88 ± 40 |
Per-emb22 | 3.6 | 293 | – | – | 4.4 × 1016 | 5.6 × 1018 | - | - | 125 ± 58 |
Ser-S68N-N | 6 | 435 | 2.8 × 1018 | – | 2.6 × 1016 | 3.1 × 1018 | 108 ± 33 | - | 120 ± 55 |
Per-emb33 | 8.3 | 293 | – | – | 6.1 × 1016 | 6.4 × 1018 | - | - | 105 ± 48 |
Per-emb35 | 9.1 | 293 | 3.7 × 1018 | – | 2.8 × 1016 | 2.8 × 1018 | 132 ± 41 | - | 99 ± 48 |
Ser-SMM3 | 28 | 435 | 1.1 × 1018 | – | 2.0 × 1016 | 2.2 × 1018 | 55 ± 17 | - | 108 ± 50 |
Per-emb27 | 36 | 293 | – | – | 5.9 × 1016 | 6.5 × 1018 | − | − | 110 ± 51 |
Notes. The main source of uncertainty in the derived ratios stems from the error on the band strength, and the observational errors are negligible in contrast (~3%). The error on the band strength includes the change in the band strength due to temperature and due to a water-rich ice mixture. The error analysis is presented in detail in Appendix A.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.