Settings used for the optical simulations and for the development of the NN.
Parameter | Value |
---|---|
F# | 25 |
Defocus [mm] | 10 |
Simulation grid points | 1024 × 1024 |
Detector pixel size [µm] | 6.5 |
Entrance Pupil Diameter [mm] | 8200 |
Wave-front sampling [mm] | 18.6 |
Final image size [pixel] | 137 × 137 |
Simulation wavelength [nm] | 656 |
λ\D [mas] | 16.5 |
# pixel corresponding to λ\D | 2.52 |
# sample training | 8000 |
# sample validation | 2000 |
# sample testing | 100 |
# PCA components | 500 |
# hidden layers | 1 |
# hidden layers neurons | 10 000 |
range ci [nm RMS] | ±50 |
# Zernike simulated | 21 |
# Zernike used for NN | 18 |