Free Access
Table A.1.
Originally modelled, measured and required performance parameters of the M-HWPB across the two NIKA bands. The labels and colours are the same as described in the data in Tab. 1. We note that this plate was part of an R&D phase and not meant to work either in the NIKA or NIKA2 instrument.
MHWPB - R& D | ||||||
---|---|---|---|---|---|---|
2mm (150GHz) | 1.25mm (240GHz) | |||||
Model | Tests | Req. | Model | Tests | Req. | |
TC | 0.960 | 0.954 | No | 0.963 | 0.943 | ≥ 0.90 |
TL | 0.902 | 0.896 | No | 0.935 | 0.932 | ≥ 0.90 |
ΔTCL | 0.058 | 0.058 | No | 0.028 | 0.011 | No |
X-pol | -19.9dB | -20.7dB | No | -14.2dB | -11.6dB | ≤ -15dB |
ΔΦCL | 186 ± 40 | 181 ± 40 | No | 166 ± 80 | 156 ± 90 | 180 ± 200 |
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.