Free Access

Table A.1

Measured or deconvolved fluxes of PILS-Cygnus sources.

Filter λ (μm) Fλ (N12) Fλ (N30) Fλ(N38)a Fλ(N48) Fλ(N51)
2MASS-J 1.22 < 1 × 10−3 < 1 × 10−3
2MASS-H 1.63 < 3 × 10−3 8 ± 3 × 10−3 < 3 × 10−3
2MASS-Ks 2.19 4 ± 2 × 10−3 4 ± 2 × 10−3 3 ± 2 × 10−3
IRAC-1 3.6 1.243 ± .002 × 10−2 6.417 ± 0.004 × 10−1 2.13 ± 0.07 × 10−3 2.9 ± 0.5 × 10−4 1.352 ± 0.1 × 10−1
IRAC-2 4.5 3.344 ± 0.002 × 10−2 1.981 ± 0.001 1.34 ± 0.02 × 10−2 4.87 ± 0.02 × 10−3 6.692 ± 0.004 × 10−1
IRAC-3 5.8 3.915 ± 0.007 × 10−2 3.902 ± 0.002 1.97 ± 0.03 × 10−2 1.14 ± 0.03 × 10−2 1.617 ± 0.001
IRAC-4 8.0 2.911 ± 0.006 × 10−2 5.361 ± 0.003 1.22 ± 0.03 × 10−2 2.42 ± 0.06 × 10−2 2.495 ± 0.003
MSX-A 8.28 8 ± 4 1.77 ± 0.07
MSX-C 12.13 14 ± 5 3.6 ± 0.2
MSX-D 14.65 19 ± 6 6.8 ± 0.4
MSX-E 21.4 54 ± 6 ≲ 28 27 ± 2
MIPS 24 1.28 ± 0.03 ≳ 17
PACS-B 70 130 ± 20 4800 ± 300 280 ± 130 180 ± 50
PACS-R 160 230 ± 10 4000 ± 200 370 ± 110 330 ± 30
SPIRE-B 250 163 ± 9 2000 ± 100 150 ± 80 240 ± 20
SPIRE-G 350 99 ± 8 660 ± 60 130 ± 20
SCUBA-B 450 80 ± 30 360 ± 60 230 ± 110 100 ± 50 140 ± 70
SPIRE-R 500 53 ± 4 320 ± 20 60 ± 30
SCUBA-R 850 9 ± 2 60 ± 20 24 ± 6 15 ± 5 10 ± 5

             

Filter λ (μm) Fλ(N53) Fλ(N54)b Fλ(N63) Fλ(S8)c Fλ(S26)c

2MASS-J 1.22 2 ± 1 × 10−3 2.0 ± 0.1 × 10−2 5 ± 1 × 10−3
2MASS-H 1.63 2 ± 2 × 10−3 9.0 ± 0.2 × 10−2 7.1 ± 0.2 × 10−2
2MASS-Ks 2.19 4 ± 2 × 10−3 2.58 ± 0.06 × 10−1 1.29 ± 0.03
IRAC-1 3.6 8.56 ± 0.05 × 10−3 1.596 ± 0.004 × 10−2 1.77 ± 0.01 × 10−3 8.9 ± 0.2 × 10−1 73.0 ± 0.6
IRAC-2 4.5 2.97 ± 0.01 × 10−2 6.913 ± 0.006 × 10−2 9.32 ± 0.02 × 10−3 1.2 ± 0.1 176 ± 4
IRAC-3 5.8 2.66 ± 0.03 × 10−2 1.992 ± 0.004 × 10−1 1.033 ± 0.006 × 10−2 3.2 ± 0.2 324 ± 2
IRAC-4 8.0 4 ± 2 × 10−3 3.18 ± 0.02 × 10−1 5.76 ± 0.07 × 10−3 5.4 ± 0.4 ≳ 190
MSX-A 8.28 2.8 ± 0.1 4.4 ± 0.2 310 ± 30
MSX-C 12.13 3.3 ± 0.2 14.6 ± 0.7 570 ± 30
MSX-D 14.65 3.4 ± 0.2 31 ± 2 800 ± 50
MSX-E 21.4 11 ± 1 145 ± 9 1020 ± 60
MIPS 24 0.52 ± 0.04 0.29 ± 0.01 ≲ 241
IRAS-25 25 ≲ 240 ≲ 1100
IRAS-60 60 ≲ 1050 ≲ 5300
PACS-B 70 50 ± 50 57 ± 6 1140 ± 60 3600 ± 200
PACS-R 160 140 ± 30 139 ± 8 1040 ± 50 1910 ± 90
SPIRE-B 250 140 ± 20 106 ± 5 390 ± 20 580 ± 30
SPIRE-G 350 90 ± 20 66 ± 4 220 ± 20 270 ± 10
SCUBA-B 450 110 ± 50 30 ± 40 45 ± 5 160 ± 50 220 ± 110
SPIRE-R 500 60 ± 10 37 ± 3 117 ± 7 107 ± 7
SCUBA-R 850 12 ± 6 12 ± 6 8 ± 3 30 ± 10 24 ± 5

aIn most filters, N38 could not be identified because the centroid of the nearest source was almost as far away as N48. The few measurements given should be treated with extreme caution.

bIn most filters, N54 could not be deblended from another object, N52, which was included in the MBS07 survey but not later works.

cNote that upper limits from IRAS are included for these two sources in Cygnus-X South.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.