Highlight
Free Access

Table 4.

Example of entries in the source catalogue.

Source name RA σRA Dec σDec Speak σSpeak Sint σSint rms noise Type
(°) (″) (°) (″) (mJy beam−1) (mJy beam−1) (mJy) (mJy) (mJy beam−1)
LOLpJ110902.0+571931 167.258 2.4 57.325 2.4 30.8 6.7 34.5 4.2 4 S
LOLpJ110903.2+515046 167.263 0.4 51.846 0.6 691.4 27.2 396.8 6.8 7 M
LOLpJ110903.3+525540 167.264 5.0 52.928 3.9 115.1 21.9 59.2 7.8 7 S
LOLpJ110903.4+514027 167.264 1.6 51.674 1.3 166.6 15.0 117.8 6.8 6 S
LOLpJ110904.3+592725 167.268 5.3 59.457 5.8 57.2 15.5 35.6 6.3 6 S
LOLpJ110905.1+551619 167.271 0.2 55.272 0.2 2633.3 42.0 2263.0 21.9 21 S
LOLpJ110905.2+460200 167.272 5.8 46.033 1.8 161.4 23.6 60.9 6.8 7 M
LOLpJ110906.1+580944 167.275 2.8 58.162 2.5 51.0 9.0 40.4 4.4 4 S
LOLpJ110906.2+474809 167.276 4.7 47.802 3.7 31.8 9.2 26.2 4.6 4 S
LOLpJ110906.4+513040 167.277 0.6 51.511 0.7 404.6 23.4 230.2 6.2 6 M
LOLpJ110909.1+512407 167.288 3.2 51.402 2.3 112.8 16.2 66.2 6.4 6 S
LOLpJ110909.2+530019 167.288 5.9 53.005 6.0 70.8 19.6 38.2 7.2 7 S
LOLpJ110910.2+494005 167.293 3.8 49.668 3.3 37.6 8.7 28.8 4.2 4 S
LOLpJ110912.2+594151 167.301 5.4 59.698 4.1 41.3 12.7 33.7 6.3 6 S
LOLpJ110912.6+532850 167.303 1.4 53.481 1.4 163.5 14.8 122.0 7.0 7 S
LOLpJ110912.7+574619 167.303 4.2 57.772 3.5 36.9 8.9 27.0 4.1 4 S
LOLpJ110913.6+580031 167.307 1.2 58.009 1.0 118.3 8.9 94.2 4.4 4 S
LOLpJ110913.9+570756 167.308 0.3 57.132 0.3 457.8 8.8 351.3 4.2 4 S
LOLpJ110914.0+542731 167.308 5.2 54.459 4.7 47.0 15.1 35.0 7.1 7 S
LOLpJ110914.1+570936 167.309 4.1 57.160 3.5 31.7 8.5 25.8 4.3 4 S

Notes. The entire catalogue contains 25 247 sources. The entries in the catalogue include: source name, J2000 right ascension (RA), J2000 declination (Dec), peak brightness (Speak), integrated flux density (Sint), and the uncertainties on all of these values. The catalogue also contains the local noise at the position of the source (rms noise), and the type of source (where ‘S’ indicates an isolated source which is fit with a single Gaussian; ‘C’ represents sources that are fit by a single Gaussian but are within an island of emission that also contains other sources; and ‘M’ is used for sources which are extended and fitted with multiple Gaussians). Not listed here, but present in the catalogue, there is also the estimation of the source size, both with and without the effect of beam convolution. The uncertainties on source positions and the flux densities are derived locally by the source finder and are likely underestimated (see text).

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.