Table 2.

MAG instrument resources.

Unit Mass (g)
Sensor (each) 500
Sensor thermal blanket (each) 55
Electronics box 2200
Sensor harness (each MEP only) 110

Total 3530

Unit Power (W)

Instrument without heaters 7.2
Sensor heaters 5.3

Notes. This table details the elements delivered by the MAG team. The harness running along the boom from the boom root to the sensors themselves was supplied by the boom contractor, and was ∼125 g m−1.