Open Access

This article has an erratum: [https://doi.org/10.1051/0004-6361/201935428e]


Table 6

Correlations between column densities of ten COMs and properties of the CALYPSO sources.

Prop.(a) Molecule Npts (b) N (c) NΩ∕Sc1 (d) NΩ∕Sc3 (e) NNCH3OH (f)




100 × ρ P 100 × ρ P 100 × ρ P 100 × ρ P
Lint CH3OH 11 2(−1) 1(−2) 1(−3)
C2H5 OH 5 3(−1) 1(−1) 8(−2) 2(−1)
CH3OCHO 9 4(−1) 1(−1) 3(−2) 1(−1)
CH3OCH3 8 2(−1) 1(−1) 8(−2) 1(−1)
CH3CHO 6 8(−1) 9(−1) 2(−1) 2(−4)
NH2CHO 6 3(−1) 1(−1) 2(−2) 9(−1)
CH3CN 10 2(−1) 2(−2) 1(−2) 5(−1)
C2H5 CN 4 1(−1) 2(−1) 2(−1) 6(−1)
a-(CH2OH)2 3
CH2 (OH)CHO 4 9(−1) 6(−1) 4(−1) 6(−3)

Menv CH3OH 11 3(−1) 4(−1) 4(−1)
C2H5 OH 5 2(−1) 3(−1) 6(−1) 3(−1)
CH3OCHO 9 8(−1) 9(−1) 9(−1) 7(−1)
CH3OCH3 8 7(−1) 2(−1) 5(−1) 6(−1)
CH3CHO 6 9(−1) 1(0) 9(−1) 1(0)
NH2CHO 6 9(−1) 9(−1) 1(0) 9(−1)
CH3CN 10 7(−1) 7(−1) 8(−1) 7(−1)
C2H5 CN 4 3(−1) 7(−1) 7(−1) 5(−2)
a-(CH2OH)2 3
CH2 (OH)CHO 4 6(−1) 7(−1) 8(−1) 1(0)

Menv /Lint CH3OH 11 8(−1) 3(−1) 2(−1)
C2H5 OH 5 6(−2) 2(−2) 7(−2) 7(−1)
CH3OCHO 9 6(−1) 3(−1) 2(−1) 2(−1)
CH3OCH3 8 5(−1) 7(−3) 3(−2) 5(−1)
CH3CHO 6 9(−1) 9(−1) 4(−1) 5(−2)
NH2CHO 6 3(−1) 2(−1) 2(−1) 8(−1)
CH3CN 10 5(−1) 2(−1) 2(−1) 8(−1)
C2H5 CN 4 1(−1) 3(−1) 1(−1) 3(−1)
a-(CH2OH)2 3
CH2 (OH)CHO 4 7(−1) 5(−1) 1(−1) 2(−1)

Notes. (a) Source property: internal luminosity (Lint), envelope mass (Menv), and ratio envelope mass over internal luminosity. (b)Number of CALYPSO sources detected or tentatively detected. Pearson correlations are evaluated for the following quantities, only when at least four sources are detected (Npts > 3): (c)column density; (d)column density times solid angle of COM emission divided by continuum flux density at 1.3 mm; (e) column density times solid angle of COM emission divided by continuum peak flux density at 3 mm; (f) column density normalized to that of CH3OH; for each type of correlation, ρ is the Pearson correlation coefficient with its 95% confidence interval, and P is the P-value. X(Y) means X × 10Y. Pearson coefficients with a confidence interval outside [−0.3, 0.3] are highlighted in bold face.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.