Free Access

Table A.2.

Observed rotational transitions of S 2 (MgC4H).

Nu(a) Ju(a) Nl(a) Jl(a) Obs.Freq. (b) Unc. (c) O-C (d) Int. (e)
26 25.5 25 24.5 71830.149 1.000 −0.943 (f) 0.155
26 26.5 25 25.5 71835.629 0.500 −0.147
27 26.5 26 25.5 74593.987 0.300 0.492 0.147
27 27.5 26 26.5 74597.613 0.300 −0.566
28 27.5 27 26.5 77355.466 0.300 −0.384
28 28.5 27 27.5 77361.172 0.300 0.638
29 28.5 28 27.5 80118.288 0.300 0.133 0.154
29 29.5 28 28.5 80122.274 0.500 n.i. (g)
30 29.5 29 28.5 [82880.409] [0.081] n.i. (h)
30 30.5 29 29.5 [82885.093] [0.082] n.i. (h)
31 30.5 30 29.5 [85642.610] [0.078] n.i. (i)
31 31.5 30 30.5 [85647.294] [0.076] n.i. (i)
32 31.5 31 30.5 88404.483 0.200 −0.273 0.164
32 32.5 31 31.5 88409.447 0.200 0.007
33 32.5 32 31.5 [91166.845] [0.078] n.i. (j)
33 33.5 32 32.5 [91171.529] [0.070] n.i. (j)
34 33.5 33 33.5 93929.043 0.200 0.166 0.136
34 34.5 33 33.5 93933.779 0.200 0.219
35 34.5 34 33.5 [96690.848] [0.092] n.i. (k)
35 35.5 34 34.5 [96695.531] [0.079] n.i. (k)
36 35.5 35 34.5 99452.794 0.500 0.037 (l) 0.151
36 36.5 35 35.5 99457.396 0.200 −0.044
37 36.5 36 35.5 [102214.602] [0.121] n.i. (g)
37 37.5 36 36.5 [102219.286] [0.105] n.i. (g)
38 37.5 37 36.5 [104976.382] [0.140] n.i. (m) 0.105
38 38.5 37 37.5 104981.775 1.000 0.709 (m)
39 38.5 38 37.5 107738.266 0.500 0.171 0.082
39 39.5 38 38.5 107741.955 0.500 −0.824
40 39.5 39 38.5 [110499.739] [0.186] n.i. (h) 0.074
40 40.5 39 39.5 [110504.422] [0.169] n.i. (h)

Notes.

(a)

Quantum numbers N and J of the rotational transition. The subindex u means upper level and l lower level.

(b)

Same as in Table A.1.

(c)

Same as in Table A.1.

(d)

Observed frequency minus calculated frequency from the fit in MHz. If n.i. the line is not included in the fit.

(e)

Main beam temperature integrated over the LSR velocity, in K km s−1. The uncertainties are below 30%.

(f)

Line contaminated with KCN.

(g)

Line contaminated with a U-line.

(h)

Line contaminated with HC4N.

(i)

Line contaminated with C4H.

(j)

Line contaminated with NaCl.

(k)

Line contaminated with several features.

(l)

Line contaminated with SiH3CN.

(m)

Line contaminated with 13CCCN.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.