Free Access

Table 2.

Same as Table 1 but for spectrum 2.

Component A
Component B
λ0 Ion Flux Relative Vr FWHM Note Flux Relative Vr FWHM Note
(nm) (10−16 erg flux (km s−1) (km s−1) (10−16 erg flux (km s−1) (km s−1)
cm−2 s−1) (Hβ = 100) cm−2 s−1) (Hβ = 100)
372.60 [O II] 0.320 37.1 –124 167 a
372.88 [O II] 0.326 37.8 –124 167 a
386.88 [Ne III] 0.063 7.3 –126 203 c 0.358 214.4 140 148 a
388.86 He I 0.109 12.6 –119 134 b 0.044 26.3 118 120 c
396.75 [Ne III] 0.021 2.4 –126 188 d 0.105 62.9 124 92 b
410.17 H I 0.131 15.2 –118 177 b 0.015 9.0 137 118 d
434.05 H I 0.292 33.9 –122 179 b 0.053 31.7 137 118 b
436.32 [O III] 0.020 12.0 145 148 d
447.15 He I 0.075 8.7 –125 193 c
486.13 H I 0.862 100.0 –129 177 a 0.167 100.0 137 115 a
495.89 [O III] 0.023 2.7 –127 106 d 0.960 574.9 144 153 a
500.68 [O III] 0.069 8.0 –127 106 c 2.960 1772.5 142 151 a
519.79 [N I] 0.800 92.8 –146 94 a
520.03 [N I] 0.869 100.8 –146 94 a
575.46 [N II] 0.188 21.8 –137 127 c
587.56 He I 0.543 63.0 –147 160 a 0.176 105.4 141 137 b
630.03 [O I] 0.937 108.7 –157 92 a
636.38 [O I] 0.338 39.2 –159 99 b
654.80 [N II] 6.752 783.3 –151 127 a 0.716 428.7 134 139 b
656.28 H I 7.240 839.9 –149 146 a 1.352 809.6 136 134 a
658.34 [N II] 21.500 2494.2 –151 130 a 1.512 905.4 134 139 a
667.82 He I 0.250 29.0 –128 177 b 0.072 43.1 107 174 c
671.64 [S II] 3.526 409.0 –153 104 a
673.08 [S II] 3.276 380.0 –154 104 a
706.52 He I 0.187 21.7 –160 134 b 0.197 118.0 154 141 b
713.58 [Ar III] 0.247 147.9 145 127 a
715.52 [Fe II] 0.159 18.4 –134 151 b
729.15 [Ca II] 0.640 74.2 –140 137 b
732.39 [Ca II] 0.442 51.3 –141 148 b
737.78 [Ni II] 0.203 23.5 –132 139 b
861.70 [Fe II] 0.530 61.5 –138 148 b
872.71 [C I] 0.080 9.3 –160 106 c
889.19 [Fe II] 0.227 26.3 –134 165 b
901.49 H I 0.113 13.1 –136 118 c
906.86 [S III] 0.100 11.6 –161 179 d 0.473 283.2 164 111 a
922.66 [Fe II] 0.074 8.6 –160 94 c
922.90 H I 0.143 16.6 –129 80 c
953.06 [S III] 0.328 38.1 –161 179 c 1.568 938.9 166 144 a
982.41 [C I] 1.344 155.9 –161 104 b
985.03 [C I] 3.816 442.7 –157 97 a

Notes. The first two columns identify the lines including their laboratory wavelength, λ0. The five subsequent columns present results of Gaussian fits to component A and the last five columns to component B. The fluxes are given in absolute units and relative to Hβ (×100). Vr is the central radial velocity of the line. Last column quantifies the flux measurements: a, flux accurate to within 10%; b, error between 10 and 30%; c, error greater than 30%; d, line marginally detected.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.