Free Access

Table 1.

Measurements of emission lines in spectrum 1.

Component A
Component B
λ0 Ion Flux Relative Vr FWHM Note Flux Relative Vr FWHM Note
(nm) (10−16 erg flux (km s−1) (km s−1) (10−16 erg flux (km s−1) (km s−1)
cm−2 s−1) (Hβ = 100) cm−2 s−1) (Hβ = 100)
372.60 [O II] 0.200 50.0 –90 132 a
372.88 [O II] 0.184 46.0 –100 120 a
386.88 [Ne III] 0.574 118.6 16 89 a
388.86 He I 0.057 14.3 –108 94 c 0.069 14.3 24 113 c
396.75 [Ne III] 0.145 30.0 18 94 a
397.01 H I 0.022 5.5 –120 130 c 0.027 5.6 10 101 c
410.17 H I 0.056 14.0 –120 144 b 0.064 13.2 10 101 b
434.05 H I 0.131 32.8 –120 118 b 0.152 31.4 10 99 b
436.32 [O III] 0.054 11.2 17 78 b
447.15 He I 0.028 7.0 –102 104 c 0.042 8.7 11 87 c
468.57 He II 0.024 6.0 –118 89 c 0.030 6.2 22 92 c
486.13 H I 0.400 100.0 –120 118 a 0.484 100.0 10 101 a
495.89 [O III] 1.632 337.2 19 87 a
500.68 [O III] 5.064 1046.3 20 87 a
501.57 He I 0.034 8.5 –107 101 c 0.046 9.5 11 92 c
519.79 [N I] 0.280 70.0 –123 118 b
520.03 [N I] 0.340 85.0 –125 120 b
575.46 [N II] 0.123 30.8 –103 106 b 0.160 33.1 9 89 b
587.56 He I 0.250 62.5 –129 97 a 0.403 83.3 8 106 a
630.03 [O I] 0.480 120.0 –116 101 b
631.21 [S III] 0.060 12.4 17 87 b
636.38 [O I] 0.175 43.8 –118 115 b
654.80 [N II] 4.296 1074.0 –114 106 a 1.288 266.1 2 120 b
656.28 H I 3.240 810.0 –138 92 a 4.000 826.4 –2 118 a
658.34 [N II] 13.500 3375.0 –114 108 a 3.920 809.9 2 120 b
667.82 He I 0.116 29.0 –123 101 b 0.145 30.0 12 94 b
671.64 [S II] 1.648 412.0 –125 97 a
673.08 [S II] 1.600 400.0 –125 97 a
706.52 He I 0.082 20.5 –136 80 b 0.413 85.3 17 101 a
713.58 [Ar III] 0.547 113.0 13 99 a
715.52 [Fe II] 0.145 36.3 –104 108 b
717.20 [Fe II] 0.024 6.0 –113 108 c
729.15 [Ca II] 0.419 104.8 –112 141 b
732.39 [Ca II] 0.445 111.3 –123 146 b
737.78 [Ni II] 0.205 51.3 –103 115 b
745.26 [Fe II] 0.052 13.0 –102 92 c
861.70 [Fe II] 0.461 115.3 –103 115 b
901.49 H I 0.048 12.0 –138 80 c 0.052 10.7 –2 118 c
905.20 [Fe II] 0.138 34.5 –100 92 b
906.86 [S III] 0.075 18.8 –110 54 c 1.280 264.5 25 115 a
922.66 [Fe II] 0.110 27.5 –95 141 b
922.90 H I 0.067 16.8 –135 82 c 0.083 17.1 22 134 c
953.06 [S III] 0.196 49.0 –110 54 b 3.620 747.9 25 115 a
954.60 H I 0.079 19.8 –134 80 c 0.096 19.8 –6 82 c
982.41 [C I] 0.372 93.0 –128 141 b
985.03 [C I] 0.946 236.5 –130 127 a
1004.98 H I 0.183 45.8 –147 99 c 0.225 46.5 –14 122 c

Notes. The first two columns identify the lines including their laboratory wavelength, λ0. The five subsequent columns present results of Gaussian fits to component A and the last five columns to component B. The fluxes are given in absolute units and relative to Hβ (×100). Vr is the central radial velocity of the line derived in the fit. Last column quantifies the flux measurements: a, flux accurate to within 10%; b, error between 10 and 30%; c, error greater than 30%.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.