Table 1.
Median values and median absolute deviation (MAD) for each parameter of three absorbers using the best-fit values of the XMM-Newton spectra.
Parameter | Median | Units |
---|---|---|
log NH, 1 | 21.88 ± 0.05 | cm−2 |
log ξ1 | 0.35 ± 0.04 | erg cm s−1 |
v1, out(*) | ∼530 | km s−1 |
log NH, 2 | 21.5 ± 0.2 | cm−2 |
log ξ2 | 0.50 ± 0.36 | erg cm s−1 |
v2, out | 0.120 ± 0.029 | c |
log NH, 3(**) | 22.9 ± 0.3 | cm−2 |
log ξ3 | 4.04 ± 0.29 | erg cm s−1 |
v3, out | 0.145 ± 0.035 | c |
log Lion | 45.4 ± 0.3 | erg s−1 |
Notes. We also report the median ionizing luminosity Lion. They were computed putting together lower and upper limits of each parameter of the XMM-Newton observations. Units are reported; in the case of logarithmic parameters, the units are to be understood as related to the argument. (*)The value of v1, out was set to 530 km s−1, following Mathur et al. (1998). (**)We computed median and MAD for the lower values of NH, 3, since we only have lower limits for two observations (see Table B.3).