Free Access

Table 3.

Results of the least-squares fit in the form of Eq. (7) or Eq. (11) for the full MW DCEPs and T2CEPs sample (top part of the table) and for the selected sample of MW DCEPs with a full characterisation in terms of reddening and metallicity estimates (bottom half part of the table).

α β γ σABL n Method Type
(1) (2) (3) (4) (5) (6) (7)
Full MW DCEPs and T2CEPs sample

−2.701 ± 0.086 −3.320 ± 0.107 0.013 489 PWA DCEP_F
−2.976 ± 0.131 −4.095 ± 0.304 0.020 138 PWA DCEP_1O
−1.194 ± 0.061 −2.381 ± 0.080 0.071 269 PWA T2CEP

−2.699 ± 0.023 −3.327 fixed 0.013 489 PWA DCEP_F
−3.246 ± 0.045 −3.471 fixed 0.020 138 PWA DCEP_1O
−1.211 ± 0.043 −2.356 fixed 0.071 269 PWA T2CEP

Selected MW DCEPs sample

−2.837 ± 0.081 −3.183 ± 0.097 0.011 292 PWA DCEP_F
−3.214 ± 0.223 −3.587 ± 0.507 0.012 33 PWA DCEP_1O
−1.942 ± 0.096 −2.454 ± 0.116 0.025 273 DCEP_F
−1.903 ± 0.302 −3.709 ± 0.712 0.026 33 DCEP_1O
−1.816 ± 0.102 −2.229 ± 0.121 0.031 273 DCEP_F
−2.100 ± 0.178 −2.776 ± 0.375 0.022 33 DCEP_1O
−2.313 ± 0.094 −2.607 ± 0.113 0.019 273 DCEP_F
−2.637 ± 0.178 −3.110 ± 0.383 0.016 33 DCEP_1O

−2.721 ± 0.025 −3.327 fixed 0.011 292 PWA DCEP_F
−3.261 ± 0.056 −3.471 fixed 0.012 33 PWA DCEP_1O
−1.688 ± 0.032 −2.765 fixed 0.025 273 DCEP_F
−2.175 ± 0.072 −3.159 fixed 0.028 33 DCEP_1O
−1.525 ± 0.033 −2.580 fixed 0.031 273 DCEP_F
−1.855 ± 0.040 −3.308 fixed 0.023 33 DCEP_1O
−2.083 ± 0.030 −2.892 fixed 0.019 273 DCEP_F
−2.593 ± 0.042 −3.204 fixed 0.016 33 DCEP_1O

−2.862 ± 0.082 −3.134 ± 0.095 −0.237 ± 0.199 0.011 261 PWAZ DCEP_F

−2.716 ± 0.028 −3.327 fixed −0.105 ± 0.207 0.011 261 PWAZ DCEP_F

Notes. The different columns show the: (1–3) coefficients of the nonlinear fit and the relative errors; (4) rms of the residuals of the ABL function; (5) number of objects used in the fit; (6) method (PL or PW); (7) type of the pulsators. To remark on the differences with Table 1, we added an underscript “A” or a superscript 0 to show that the magnitudes adopted are absolute and/or de-reddened, respectively. “Fixed” means that the slope of LMC (β) was imposed to derive the other parameters; PWAZ indicates a PW relation depending on metallicity.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.