Highlight
Free Access

Table 5

Spectral parameters from a power-law fit to each of the 38 boxes independently.

Box d(pc) Γ Φ (1−5 TeV) σ
1 51 2.32 ± 0.05 ± 0.03 4.3 ± 0.2 ± 0.2 28.8
2 41 2.21 ± 0.04 ± 0.03 5.9 ± 0.2 ± 0.3 34.2
3 36 2.24 ± 0.06 ± 0.03 4.3 ± 0.2 ± 0.2 24.6
4 41 2.29 ± 0.04 ± 0.03 6.0 ± 0.2 ± 0.2 38.8
5 26 2.13 ± 0.03 ± 0.03 9.6 ± 0.3 ± 0.4 51.4
6 18 2.09 ± 0.04 ± 0.02 6.9 ± 0.3 ± 0.3 35.05
7 36 2.20 ± 0.04 ± 0.02 5.4 ± 0.2 ± 0.2 33.7
8 18 2.06 ± 0.03 ± 0.01 10.4 ± 0.3 ± 0.3 53.6
9 0 2.00 ± 0.03 ± 0.02 8.7 ± 0.3 ± 0.3 41.6
10 41 2.29 ± 0.07 ± 0.05 2.9 ± 0.2 ± 0.2 20.7
11 26 2.20 ± 0.05 ± 0.03 4.3 ± 0.2 ± 0.1 26.4
12 18 2.06 ± 0.06 ± 0.04 4.0 ± 0.2 ± 0.2 20.5
a 106 3.3 ± 0.2 ± 0.2 0.5 ± 0.1 ± 0.01 8.8
b 98 3.2 ± 0.2 ± 0.8 0.6 ± 0.2 ± 0.4 6.9
c 93 3.3 ± 0.3 ± 0.3 0.5 ± 0.2 ± 0.3 6.9
d 103 3.1 ± 0.3 ± 0.4 0.5 ± 0.2 ± 0.01 6.2
e 91 2.90 ± 0.13 ± 0.05 1.2 ± 0.2 ± 0.1 12.8
f 81 2.8 ± 0.1 ± 0.1 1.3 ± 0.2 ± 0.2 13.3
g 75 2.7 ± 0.1 ± 0.1 1.3 ± 0.2 ± 0.2 11.1
h 73 2.9 ± 0.2 ± 0.1 0.8 ± 0.2 ± 0.1 8.2
i 91 3.1 ± 0.2 ± 0.1 0.7 ± 0.2 ± 0.2 9.4
j 77 2.61 ± 0.09 ± 0.07 2.1 ± 0.2 ± 0.2 17.7
k 65 2.43 ± 0.07 ± 0.04 2.8 ± 0.2 ± 0.1 20.4
l 57 2.40 ± 0.07 ± 0.03 3.1 ± 0.2 ± 0.2 21.0
m 56 2.40 ± 0.10 ± 0.05 2.2 ± 0.2 ± 0.1 14.5
n 57 2.45 ± 0.15 ± 0.3 1.3 ± 0.2 ± 0.1 8.7
o 98 2.8 ± 0.2 ± 0.1 0.9 ± 0.2 ± 0.1 9.7
p 81 2.72 ± 0.11 ± 0.09 1.6 ± 0.2 ± 0.2 15.1
q 65 2.33 ± 0.07 ± 0.02 3.0 ± 0.2 ± 0.2 21.2
r 41 2.59 ± 0.1 ± 0.03 1.9 ± 0.2 ± 0.2 13.8
s 75 2.8 ± 0.1 ± 0.1 1.1 ± 0.2 ± 0.2 13.7
t 57 2.3 ± 0.07 ± 0.02 3.2 ± 0.2± 0.2 22.4
u 56 2.28 ± 0.08 ± 0.07 2.6 ± 0.2 ± 0.3 19.2
v 57 2.47 ± 0.13 ± 0.06 1.4 ± 0.2 ± 0.1 12.4
w 65 2.45 ± 0.16 ± 0.1 1.3 ± 0.2 ± 0.2 10.7
x 51 2.71 ± 0.16 ± 0.2 1.0 ± 0.2 ± 0.2 10.6
y 41 2.5 ± 0.2 ± 0.1 1.2 ± 0.2 ± 0.1 9.8
z 36 2.6 ± 0.2 ± 0.09 1.0 ± 0.2 ± 0.1 8.1

Notes. The integrated flux from 1−5 TeV is given in units of 10−13 cm−2 s−1. For all results, the first error provided is statistical and the second systematic. The projected distance of the centre of each box to the pulsar is given for an assumed distance of 4 kpc; the significance of the spectrum obtained from each box is also provided.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.