Table A.1.
Benchmark between FITWAT and ASFIT in fitting data for chlorobenzene.
Molecular parameters | Units MHz × | FITWAT a | ASFIT b |
---|---|---|---|
A | 5672.2931(133) | 5672.2932(133) | |
B | 1576.786974(380) | 1576.786976(381) | |
C | 1233.674849(278) | 1233.674849(278) | |
ΔJ | 10−05 | 6.02946(184) | 6.02946(184) |
ΔJK | 10−04 | 2.81972(111) | 2.81973(111) |
ΔK | 10−04 | 9.046(309) | 9.047(309) |
δJ | 10−05 | 1.44719(104) | 1.44720(104) |
δK | 10−04 | 3.07111(687) | 3.07112(688) |
Nc | 186 | 186 | |
Jmax | ..... | 105 | 105 |
Kmax | ..... | 46 | 46 |
νmax | 261303.45 | 261303.45 | |
σ | 0.067 | 0.067 | |
σw | ..... | 0.355 | 0.355 |
Notes. Numbers in parentheses represent the derived uncertainty (1σ) of the parameter in units of the last digit.
Rotational and centrifugal distortion constants obtained by FITWAT in the fit to the lines of chlorobenzene reported by Kisiel (1990).
Rotational and centrifugal distortion constants obtained by ASFIT in the fit to the lines of chlorobenzene reported by Kisiel (1990).
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.