Free Access

Table B.1

Comparison of SOAP3.0 with EXORINGS using Table 1 input.

Ring angles Transit depth (ppm) Total transit duration (h)

i r θ EXORINGS SOAP3.0 SOAP3.0(LD) EXORINGS SOAP3.0

0 0 27 500 27 515 32 387 6.380 6.383
20 0 26 444 26 450 31 144 6.380 6.383
45 0 22 374 22 387 26 364 6.380 6.383
70 0 14 047 14 052 16 567 6.380 6.383
90 0 10 000 10 000 11 792 6.380 5.850
0 45 27 500 27 515 32 387 6.026 6.383
90 45 10 000 10 000 11 844 6.024 6.350

Input from Tusnski & Valio (2011) [TV11]: Rp = 0.084 R, Rin = 1.11, Rout = 2.32, ip = 88°, τ = 0.5, (u1,u2) = (0.2925, 0.3475)

ir θ TV11 SOAP3.0 SOAP3.0(LD) TV11 SOAP3.0

78 20 10 500 10 800 12 374 3.40 3.41

Notes. Also comparison with quoted values of Tusnski & Valio (2011) using input values from the paper. SOAP3.0(LD) corresponds to results when limb darkening is used. Asterisk () denotes orientations where the transit duration of EXORINGS and SOAP3.0 differs.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.