Free Access

Table A.2

Summary of HVC absorption-line measurements.

No. QSO (COS name) Ion λ0 S/N a vmin vmax W λ b ΔWλ log Nc Δ(log N)
[Å] [km s-1] [km s-1] [mÅ] [mÅ]

1 J142947.03+064334.9 CII 1334.5 6 –155 –100 145 27 >14.03
2 J142947.03+064334.9 CIV 1548.2 6 –165 –99 123 35 13.77 0.13
3 J142947.03+064334.9 CIV 1550.8 6 –131 –100 42 22 13.55 0.16
4 J142947.03+064334.9 SiII 1190.4 5 –133 –103 50 19 13.17 0.20
5 J142947.03+064334.9 SiII 1193.3 5 –149 –100 94 26 >13.32
6 J142947.03+064334.9 SiII 1260.4 6 –155 –100 124 23 >13.15
7 J142947.03+064334.9 SiII 1526.7 5 –142 –99 59 32 13.64 0.26
8 J142947.03+064334.9 SiIII 1206.5 4 –167 –99 122 39 >12.81

9 PKS2005-489 CII 1334.5 24 101 202 125 11 13.89 0.06
10 PKS2005-489 CIV 1548.2 18 101 167 91 13 13.50 0.10
11 PKS2005-489 SiII 1193.3 25 101 187 68 9 13.11 0.08
12 PKS2005-489 SiII 1260.4 34 99 206 123 8 13.07 0.04
13 PKS2005-489 SiIII 1206.5 25 101 203 143 9 13.00 0.06

14 LBQS-1435-0134 CII 1334.5 31 –136 –100 57 4 13.59 0.07
15 LBQS-1435-0134 CIV 1548.2 35 –183 –100 118 8 13.58 0.05
16 LBQS-1435-0134 SiII 1190.4 32 –121 –100
17 LBQS-1435-0134 SiII 1260.4 39 –156 –100 59 4 12.75 0.05
18 LBQS-1435-0134 SiIII 1206.5 35 –180 –100 49 6 12.44 0.07

Notes. Full version of Table A.2 is only available in electronic form at the CDS.

(a)

S/N per resolution element.

(b)

A “t” in front of the equivalent width indicates a tentative HVC detection.

(c)

For each ion, the maximum value for N is adopted for the further column-density analysis (see Sect. 2.2).

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.