Free Access

Table 3

Features of the observed lines (Herschel plus published/archival data available).

Target Line Wavelength Instrument Integrated intensity FWHM v LSR
(μm) (W m-2) (W m-2 sr-1) (km s-1) (km s-1)

105-600 [CII] 158 μm 157.74 HIFI 2.39e-16 (12%) 3.68e-07c 6.4 –23.1
CO (7-6) 371.65 HIFI 1.18e-17 (11%) ... 2.7 –22.7
CO (10-9) 260.24 HIFI 2.26e-17 (14%) ... 2.5 –22.8
CO (15-14) 173.63 PACS 5.50e-18 (24%) ... ... ...
CO (17-16) 153.27 PACS 7.59e-18 (24%) ... ... ...
CO (19-18) 137.20 PACS <2.65e-17a (20%) ... ... ...
[OI] 63 μm 63.18 PACS 2.90e-15 (12%) 4.47e-06c ... ...
CO (3-2) 866.96 APEX/FLASH+ 2.98e-18 (20%) ... 3.2 –22.7
CO (4-3) 650.25 APEX/FLASH+ 6.67e-18 (20%) ... 3.1 –22.7
CO (6-5) 433.56 APEX/CHAMP+ 1.26e-17 (20%) ... 3.5 –22.6
CO (7-6) 371.65 APEX/CHAMP+ 1.40e-17 (20%) ... 4.1 –22.3
CO (3-2) 906.83 APEX/FLASH+ 7.12e-19 (20%) ... 2.2 –22.6
HCO+ (4-3) 840.41 APEX/FLASH+ 2.97e-19 (20%) ... 2.0 –22.6
HCN (4-3) 845.66 APEX/FLASH+ 1.72e-19 (20%) ... 1.8 –22.8

HST10 [CII] 158 μm 157.74 HIFI <2.27e-16b (12%) 4.72e-06b,c 3.9 21.3
CO (7-6) 371.65 HIFI <4.32e-18a (11%) 5.84e-06a,c ... ...
CO (10-9) 260.24 HIFI <2.63e-17a (14%) 3.56e-05a,c ... ...
CO (15-14) 173.63 PACS <7.15e-16b (13%) 9.68e-04b,c ... ...
CO (17-16) 153.27 PACS <3.47e-16b (13%) 4.70e-04b,c ... ...
CO (19-18) 137.20 PACS <1.44e-16b (13%) 1.95e-04b,c ... ...
[OI] 63 μm 63.18 PACS <1.01e-13b (12%) 2.10e-03b,c ... ...
H2 1-0 S(1) 2.12 HST/NICMOS 1.85e-18c (20%) 2.50e-06 ... ...
[OI] 6300 Å 0.63 HST/WFPC2 1.11e-17c (34%) 1.50e-05 ... ...

244-440 [CII] 158 μm 157.74 HIFI <4.68e-16b (12%) 8.09e-07b,c 2.2 21.7
CO (7-6) 371.65 HIFI <2.69e-18a (11%) 2.46e-07a,c ... ...
CO (10-9) 260.24 HIFI <1.53e-17a (14%) 1.40e-06a,c ... ...
CO (15-14) 173.63 PACS <4.19e-15b (13%) 3.83e-04b,c ... ...
CO (17-16) 153.27 PACS <2.72e-15b (13%) 2.49e-04b,c ... ...
CO (19-18) 137.20 PACS <8.16e-16b (13%) 7.45e-05b,c ... ...
[OI] 63 μm 63.18 PACS <2.06e-13b (12%) 3.55e-04b,c ... ...
OH 84 μm 84.45 PACS 6.83e-18 (13%) 6.24e-07c ... ...

203-506 HCO+ (4-3) 840.41 ALMA 3.04e-20c (10%) 3.60e-09 4.0 9.5
H2 1-0 S(1) 2.12 CFHT 7.01e-18c (11%) 8.30e-07 ... ...
[OI] 6300 Å 0.63 HST/WFPC2 – MUSE 1.01e-16c ... 1.20e-05 ... ...

Notes. 1σ-relative uncertainties of integrated intensities are given in parentheses after each value and take into account instrumental accuracy and fitting uncertainties. Other uncertainties are not indicated, they are below 5% for the full width at half maximum (FWHM) and are estimated to be smaller than a percent for the velocity with respect to the local standard of rest (vLSR).

(a)

Upper limit determined by the noise (peak of the line supposed to be smaller than three times the noise level).

(b)

Upper limit determined by the observed background emission.

(c)

Values converted using the apparent size given in Table 1 and assuming that all the lines are coming from the disk except for [CII] 158 μm and [OI] 63 μm lines that are supposed to originate in the envelope.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.