Table 2
Overview of the properties of the lines detected with ALMA.
Physical | Technical | |||||||
Molecule | Transition | ν | E u | ncrit(100 K) | θ beam | σ ch - rms | n clip | v int |
[GHz] | [K] | [cm-3] | [![]() |
[mJy beam-1] | [km s-1] | |||
|
||||||||
13CS | 2–1 | 92.494 | 6.66 | 3.3 ×105 | 1.93 × 1.57 | 0.52 | 3 | –130–130 |
N2H+ | 1–0 | 93.174 | 4.47 | 2.0 ×105 | 1.93 × 1.57 | 0.53 | 4 | –150–100 |
H51β | 93.607 | 1.93 × 1.57 | 0.54 | 3 | –370–340 | |||
CH3OH-A | 80–71 | 95.169 | 83.50 | 7.9 ×105 | 1.89 × 1.55 | 0.52 | 3 | –120–130 |
H49β | 105.302 | 1.72 × 1.44 | 0.54 | 3 | –350–320 | |||
H39α | 106.737 | 1.75 × 1.48 | 0.62 | 3 | –440–400 | |||
CS | 5–4 | 244.936 | 35.30 | 5.4 ×106 | 0.76 × 0.59 | 0.91 | 5 | –150–200 |
HC3N | 27–26 | 245.606 | 165.03 | 0.76 × 0.59 | 0.87 | 3 | –70–100 | |
H36β | 260.033 | 0.70 × 0.55 | 1.10 | 3 | –330–340 | |||
H13CO+ | 3–2 | 260.255 | 24.98 | 3.3 ×106 | 0.70 × 0.55 | 1.10 | 3 | –80–110 |
SiO | 6–5 | 260.518 | 43.76 | 8.3 ×106 | 0.70 × 0.55 | 0.90 | 4 | –150–210 |
SO 3Σ | 67–56 | 261.844 | 47.60 | 3.7 ×106 | 0.70 × 0.56 | 1.00 | 4 | –80–100 |
C2H | 33.5, 4–22.5, 3 | 262.004 | 25.15 | 6.3 ×106 | ||||
C2H | 33.5, 3–22.5, 2 | 262.006 | 25.15 | 6.5 ×106 | ||||
C2H | 32.5, 3–21.5, 2 | 262.065 | 25.16 | 6.7 ×106 | 0.70 × 0.56 | 1.00 | 4 | –190–80 |
C2H | 32.5, 2–21.5, 1 | 262.067 | 25.16 | 6.9 ×106 | ||||
H33β | 335.207 | 0.50 × 0.42 | 1.28 | 5 | –390–100 | |||
CH3OH-E | 7-1–6-1 | 338.345 | 70.60 | 1.3 ×106 | 0.50 × 0.42 | 1.28 | 3 | –80–100 |
CH3OH-A | 70–60 | 338.409 | 65.00 | 1.4 ×106 | ||||
SiO | 8–7 | 347.331 | 75.02 | 2.0 ×107 | 0.48 × 0.41 | 1.90 | 4 | –150–200 |
Notes. Listed are the frequencies ν; upper state energies Eu; critical densities ncrit in the two-level approximation for given kinetic temperature based on data from the Leiden Atomic and Molecular Database (LAMDA; Schöier et al. 2005, http://home.strw.leidenuniv.nl/~moldata/); beam sizes θbeam, channel noise σch - rms, and noise clipping level from nclipσch - rms per line cube; velocity range vint over which the integrated flux maps were obained.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.