Free Access

Table 4

HCO+ outer radii and line detections.

Source R(HCO+) T0 Flux Line width Detection? Rinter Ref.
(au) (K) (Jy  km s-1) km s-1 HCN CCH CS (au)
(1) (2) (3) (4) (5) (6) (7) (8) (9) (10)

04302+2247 860 30 12.65 4.83 ± 0.09 10.5 6.1 750 ± 56 CN, 2
AA Tau 440 15 1.71 5.17 ± 0.67 5.1 3.1 3.9 500 CO, 13
AB Aur 520 30 4.79 2.89 ± 0.14 7.2 3.0 890 ± 10 13CO, 14
CI Tau 560 15 2.70 3.17 ± 0.22 4.8 4.1 3.8 520 ± 13 CN, 2
CQ Tau 250 30 1.12 7.19 ± 1.87 3.2 200 ± 20 CO, 16
CW Tau 230 15 0.46 1.64 ± 0.38 210 ± 7 13CO, 1
CY Tau 490 15 2.12 1.98 ± 0.13 6.3 7.0 4.0 295 ± 11 CN, 2
DL Tau 700 15 4.30 2.83 ± 0.09 8.1 4.1 463 ± 6 CO, CN, 2
DM Tau 780 15 5.23 1.90 ± 0.05 20.4 14.4 3.4 800 ± 30 HCO+ 10, 11
DN Tau 390 15 1.34 2.75 ± 0.28 7.6 4.7 241 ± 7 CN, 2
DO Tau 330 15 0.93 1.99 ± 0.31 5.1 300 CN, 17
FT Tau 350 15 1.08 2.64 ± 0.43 4.2 > 60 cont, 5
GG Tau 610 30 6.59 2.79 ± 0.07 18.1 9.9 6.6 800 13CO, 9
GM Aur 710 15 4.37 4.06 ± 0.16 9.3 6.3 525 ± 20 CO, 12
GO Tau 790 15 5.39 2.16 ± 0.06 23.2 19.2 587 ± 55 CN, 2
Haro 6-13 510 15 2.28 2.83 ± 0.25 4.0 >180, 280 CO, 6; CN, 17
Haro 6-33 610 30 3.21 2.43 ± 0.11 6.7 11.9 300 ± 10, 260 ± 30 CO, 6; CN, 17
Haro 6-5B 570 15 2.83 5.92 ± 0.52 600, 310 13CO 4; CN, 17
HH 30 480 15 2.01 3.41 ± 0.57 420 ± 25 13CO, 7
HK Tau 400 30 2.74 9.27 ± 0.91 4.1 > 200 CO, 8
HV Tau C 410 30 2.97 8.45 ± 0.74 256 ± 51 CN, 2
IQ Tau 500 15 2.17 4.87 ± 0.53 4.3 3.9 4.6 220 ± 15 CN, 2
LkHα 358 170 15 0.26 0.42 ± 0.16 150 ± 17 CO, 6
LkCa 15 760 15 5.03 3.67 ± 0.13 24.7 9.0 4.4 660 ± 60 HCO+ 10, 11
MWC 480 490 30 4.27 3.86 ± 0.13 11.6 9.1 520 ± 50 HCO+ 10, 11
MWC 758 210 30 0.80 2.62 ± 0.35 270 ± 15 CO, 16
RW Aur 390 30 2.67 12.78 ± 1.61 50 CO, 15
RY Tau 330 30 1.90 10.15 ± 1.83 4.4 3.6 400 CO, 3
SU Aur 300 30 1.58 7.27 ± 1.51 > 150 13CO, 1
UZ Tau E 240 30 0.99 5.57 ± 1.36 3.0 300 ± 20 CO, 10

Notes. HCO+ outer radii (Col. 2) for the assumed temperature (Col. 3). Columns 45 are the line flux and width. Cols. 68 indicate the S/N for line detections. Column 9 indicates interferometric radii Rinter (or, when in italics, Rsingle from reference [17]), for the molecules and references given in Col. 10.

Reference. [1] Piétu et al. (2014); [2] Guilloteau et al. (2014); [3] Coffey et al. (2015); [4] Yokogawa et al. (2002); [5] Guilloteau et al. (2011); [6] Schaefer et al. (2009); [7] Pety et al. (2006); [8] Jensen & Akeson (2014); [9] Guilloteau et al. (1999); [10] Simon et al. (2000); [11] Piétu et al. (2007); [12] Dutrey et al. (1998); [13] Kessler-Silacci, 2004; PhD Thesis; [14] Piétu et al. (2005); [15] Cabrit et al. (2006); [16] Chapillon et al. (2008); [17] Guilloteau et al. (2013), single-dish estimate from CN line flux.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.