Table B.1
Experimental data for CHCH
CN.
Nr.: | J′′ |
![]() |
![]() |
J ′ |
![]() |
![]() |
Frequency | Unc. | O−C | Weight |
|
||||||||||
1: | 17 | 1 | 17 | 16 | 0 | 16 | 150 042.190 | 0.030 | 0.0147 | |
2: | 33 | 2 | 31 | 33 | 1 | 32 | 150 331.396 | 0.030 | 0.0241 | |
3: | 42 | 5 | 37 | 41 | 6 | 36 | 150 403.376 | 0.030 | 0.0502 | |
4: | 18 | 0 | 18 | 17 | 1 | 17 | 150 425.187 | 0.030 | −0.0073 | |
5: | 17 | 8 | 9 | 16 | 8 | 8 | 150 780.154 | 0.030 | −0.0067 | 0.5000 |
6: | 17 | 8 | 10 | 16 | 8 | 9 | 150 780.154 | 0.030 | −0.0067 | 0.5000 |
7: | 17 | 9 | 8 | 16 | 9 | 7 | 150 784.377 | 0.030 | −0.0058 | 0.5000 |
8: | 17 | 9 | 9 | 16 | 9 | 8 | 150 784.377 | 0.030 | −0.0058 | 0.5000 |
9: | 17 | 7 | 10 | 16 | 7 | 9 | 150 789.125 | 0.030 | −0.0089 | 0.5000 |
10: | 17 | 7 | 11 | 16 | 7 | 10 | 150 789.125 | 0.030 | −0.0089 | 0.5000 |
6814: | 28 | 17 | 11 | 27 | 16 | 12 | 985 858.551 | 0.030 | 0.0231 | 0.5000 |
6815: | 28 | 17 | 12 | 27 | 16 | 11 | 985 858.551 | 0.030 | 0.0231 | 0.5000 |
6816: | 64 | 10 | 54 | 63 | 9 | 55 | 986 054.883 | 0.030 | −0.0011 | |
6817: | 33 | 16 | 17 | 32 | 15 | 18 | 986 740.931 | 0.030 | 0.0011 | 0.5000 |
6818: | 33 | 16 | 18 | 32 | 15 | 17 | 986 740.931 | 0.030 | 0.0011 | 0.5000 |
6819: | 48 | 13 | 35 | 47 | 12 | 36 | 987 077.762 | 0.030 | −0.0157 | 0.5000 |
6820: | 48 | 13 | 36 | 47 | 12 | 35 | 987 077.762 | 0.030 | −0.0157 | 0.5000 |
6821: | 38 | 15 | 23 | 37 | 14 | 24 | 987 305.187 | 0.030 | −0.0727 | 0.5000 |
6822: | 38 | 15 | 24 | 37 | 14 | 23 | 987 305.187 | 0.030 | −0.0727 | 0.5000 |
6823: | 43 | 14 | 29 | 42 | 13 | 30 | 987 468.359 | 0.030 | 0.0128 | 0.5000 |
6824: | 43 | 14 | 30 | 42 | 13 | 29 | 987 468.359 | 0.030 | 0.0128 | 0.5000 |
Notes. The table contains the line number, rotational quantum numbers of the assigned transition, observed transition frequency (MHz), experimental uncertainty (MHz), residual O−C between observed frequency and that calculated from the final set of spectroscopic parameters, and weight for blended lines. This table as well as those of other conformers are available in their entirety in electronic form at CDS. A portion is shown here for guidance regarding its form and content.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.