Free Access

Table 1

Transitions of (CH2OH)2 in the observed frequency range.

Transition Frequency E up log 10(Aul) Rotational diagram
[MHz] [K] [s-1]

3 mm observations

91,8v = 1−81,7v = 0 100 333.6424 23.6 –4.6773 W51/e2
93,6v = 1−83,5v = 0 100 490.6121 27.0 –4.6800
111,10v = 1−102,9v = 1 102 064.0770 33.9 –4.6692
101,10v = 1−91,9v = 0 102 291.5860 26.2 –4.5798
92,7v = 1−82,6v = 0 102 539.4267 25.0 –4.6355
100,10v = 1−90,9v = 0 102 689.8384 26.1 –4.4419
119,2v = 0−109,1v = 1 105 574.9490 72.2 –4.9342
118,4 / 3v = 0−108,3 / 2v = 1 105 644.1940 63.9 –4.5179
111,10v = 0−101,9v = 1 105 701.0020 33.6 –4.3644
117,5 / 4v = 0−107,4 / 3v = 1 105 735.3520 56.5 –4.4051
113,9v = 0−103,8v = 1 105 834.6960 36.9 –4.5676
116,6 / 5v = 0−106,5 / 4v = 1 105 866.9546 50.1 –4.3228
115,7v = 0−105,6v = 1 106 072.0524 44.7 –4.6197
115,6v = 0−105,5v = 1 106 088.9178 44.8 –4.5104

1 mm observations

2417,8 / 7v = 0−2317,7 / 6v = 1 238 828.3252 289.3 –3.4806
2416,9 / 8v = 0−2316,8 / 7v = 1 238 904.3833 273.1 –3.4330
2415,10 / 9v = 0−2315,9 / 8v = 1 238 993.6343 257.9 –3.3925
3012,19 / 18v = 1−3011,19 / 20v = 0 238 994.0910 299.7 –4.8643
225,17v = 1−215,16v = 0 238 994.7545 138.6 –3.5149
2413,12 / 11v = 0−2313,11 / 10v = 1 239 231.3329 230.4 –3.3269
2412,13 / 12v = 0−2312,12 / 11v = 1 239 395.0677 218.2 –3.3002
2411,14 / 13v = 0−2311,13 / 12v = 1 239 605.3330 206.9 –3.2765
253,23v = 0−243,22v = 1 239 792.7984 161.6 –3.4697
2410,15 / 14v = 0−2310,14 / 13v = 1 239 883.5631 196.7 –3.2555 W51/e2
252,23v = 0−242,22v = 1 239 957.1582 161.6 –3.4917
234,20v = 1−224,19v = 0 239 980.0390 144.1 –3.4495
243,21v = 0−233,20v = 1 240 147.9627 155.2 –3.4704
249,16 / 15v = 0−239,15 / 14v = 1 240 265.7687 187.4 –3.2365
224,19v = 0−213,18v = 0 240 608.1463 132.6 –3.9839
251 / 0,25v = 1−241 / 0,24v = 0 240 778.3210 148.0 –3.1643
248,17v = 0−238,16v = 1 240 807.8795 179.2 –3.5201 W51/e2 and G34.3+0.2
248,16v = 0−238,15v = 1 240 828.8863 179.2 –3.5199
224,18v = 1−214,17v = 0 240 875.3680 135.5 –3.4905
5910,50v = 1−599,51v = 1 240 888.3533 925.5 –4.4992
245,20v = 0235,19v = 1 241 291.2695 160.7 –3.5046
247,18v = 0−237,17v = 1 241 545.2626 172.1 –3.5045
247,17v = 0−237,16v = 1 241 817.6908 172.1 –3.5026
246,19v = 0−236,18v = 1 241 860.7330 166.0 –3.5459
2315,9 / 8v = 1−2215,8 / 7v = 0 242 244.6928 246.4 –3.4004
2314,10 / 9v = 1−2214,9 / 8v = 0 242 246.3392 232.2 –3.3608
2316,8 / 7v = 1−2216,7 / 6v = 0 242 267.1576 261.6 –3.4470
2313,11 / 10v = 1−2213,10 / 9v = 0 242 277.7167 218.9 –3.3268
2317,7 / 6v = 1−2217,6 / 5v = 0 242 309.7823 277.8 –3.5027
2312,12 / 11v = 1−2212,11 / 10v = 0 242 347.0348 206.7 –3.2973
2318,6 / 5v = 1−2218,5 / 4v = 0 242 369.7298 295.0 –3.5709
262 / 1,25v = 0−252 / 1,24v = 1 242 389.2838 166.9 –3.1601
2311,13 / 12v = 1−2211,12 / 11v = 0 242 466.6909 195.4 –3.2714
2310,14 / 13v = 1−2210,13 / 12v = 0 242 656.2283 185.2 –3.2486 W51/e2 and G34.3+0.2
233,20v = 1−22319v = 0 242 897.4293 143.6 –3.7464
239,15 / 14v = 1−229,14 / 13v = 0 242 948.2909 175.9 –3.2282 W51/e2
246,18v = 0−236,17v = 1 243 259.7398 166.3 –3.8001
238,16v = 1−228,15v = 0 243 396.0258 167.7 –3.5106
238,15v = 1−228,14v = 0 243 408.4357 167.7 –3.5105
235,19v = 1−22518v = 0 243 636.5668 149.1 –3.4704
237,17v = 1−227,16v = 0 244 054.2878 160.5 –3.4934
237,16v = 1−227,15v = 0 244 233.4545 160.5 –3.4927
243,22v = 1−233,21v = 0 244 399.6722 150.1 –3.4754
242,22v = 1−232,21v = 0 244 685.1477 150.1 –3.4399
236,18v = 1−226,17v = 0 244 879.9193 154.4 –3.5188
271 / 0,27v = 0−261 / 0,26v = 1 245 022.7624 171.4 –3.1407
246,19v = 1−236,17v = 1 245 410.9218 166.3 –3.7580

Notes. Catalog values for the (CH2OH)2 transitions that can be excited in the observed frequency range for W51/e2 and G34.3+0.2. Some faint transitions have been excluded from this table, please Sect. 3. The source names are listed for the lines that are used in the rotational diagram analysis.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.