Free Access

Table 2

Best-fit parameters and errors, for the individual XMM-Newton and Chandra observations.

Obscurer componentsa WA componentsb
Obs Γ c N H, warm d C V, warm e N H, cold d C V, cold e ξ A f ξ B f ξ C f ξ D f ξ E f ξ F f C/Expected Cg
(1022 cm-2) (1022 cm-2) (log erg cm s-1)

XM1 1.5 ** 1.7 ± 0.1 0.86 ± 0.01 12 ± 1 0.47 ± 0.02 {0.33* 1.06* 1.70* 1.91* 2.48* 2.67*} 384/334
XM2 1.58 ± 0.03 1.04 ± 0.04 0.927 ± 0.005 10 ± 2 0.170 ± 0.03 422/345
XM3 1.5** 1.42 ± 0.06 0.909 ± 0.005 11 ± 3 0.18 ± 0.02 379/337
XM4 1.60 ± 0.03 1.17 ± 0.04 0.922 ± 0.004 14 ± 2 0.19 ± 0.03 406/346
XM5 1.57 ± 0.03 1.44 ± 0.05 0.915 ± 0.004 8 ± 1 0.24 ± 0.03 435/335
XM6 1.5** 1.4 ± 0.1 0.916 ± 0.005 5 ± 1 0.30 ± 0.08 415/341
XM7 1.5** 1.40 ± 0.05 0.909 ± 0.005 12 ± 2 0.27 ± 0.03 394/340
XM8 1.53 ± 0.03 1.62 ± 0.07 0.88 ± 0.05 9 ± 1 0.35 ± 0.03 389/339
XM9 1.64 ± 0.03 1.58 ± 0.05 0.896 ± 0.004 11 ± 2 0.24 ± 0.03 390/340
XM10 1.57 ± 0.03 1.43 ± 0.05 0.911 ± 0.004 9 ± 1 0.24 ± 0.03 434/344
XM11 1.56 ± 0.03 1.46 ± 0.05 0.902 ± 0.004 10 ± 2 0.23 ± 0.03 399/340
XM12 1.5** 1.43 ± 0.04 0.922 ± 0.005 12 ± 2 0.27 ± 0.03 447/338

CH1 1.83* 1.7 ± 0.2 0.74 ± 0.03 17* 0.23 0.38* 1.11* 1.75* 1.96* 2.53* 2.72* 149/152
CH2+3 1.83 ± 0.02 1.49 ± 0.08 0.79 ± 0.07 17 ± 3 0.35 ± 0.03 0.38 1.11 1.75 1.96 2.53 2.72 530/311

XM13 1.5** 1.7 ± 0.1 0.87 ± 0.02 9 ± 2 0.33 ± 0.03 0.33* 1.06* 1.70* 1.91* 2.48* 2.67* 415/340
XM14 1.59 ± 0.01 1.22 ± 0.03 0.917 ± 0.003 10 * 0.003 0.39 1.12 1.76 1.97 2.54 2.73 485/342

K14*** 1.566 ± 0.009 1.21 ± 0.03 0.86 ± 0.02 9.6 ± 0.5 0.30 ± 0.10 0.33 1.06 1.70 1.91 2.48 2.67

Notes. In the last row, we list also the parameters derived in K14 for the average XM112 spectrum for comparison.

(a)

For the warm obscurer: log ξ = −1.25. For the cold obscurer: log ξ = − 4.

(b)

For Obs. CH2+3, XM14, and K14, the ionization parameters given the output of the iterative fitting procedure described in Sect. 4.2.

(c)

Photon index of the primary continuum.

(d)

Column density of the obscurer components.

(e)

Covering fraction of the obscurer components.

(f)

Ionization parameters of the warm absorber components.

(g)

C-statistics of the final best-fit model.

(*)

Frozen parameters.

(**)

Lower limit of the fitting range.

(***)

Best-fit parameters derived in K14 for the coadded XM112 spectrum.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.