Free Access

Table 1

Description of important user-set parameters in AZEuS.

Parameter name Description Range

courno the Courant number 0–1
qcon quadratic artificial viscosity parametera 0
qlin linear artificial viscosity parametera 0
ibuff number of buffer zones placed around a new grid 0
geffcy minimum allowed fractional grid efficiency for creation of a new grid 0–1
kcheck number of cycles at a level between refinement checks 0
nrtoler tolerance for max. relative change in ER during one call to the radiation solver >0
nrtolrhs tolerance for max. magnitude of the matrix RHS during one call to the radiation solver 0
slstol relative tolerance of the iterative matrix solver >0
dttoler maximum desired relative change in ER during one call to the radiation solver >0

Notes.

(a)

We refer the reader to Clarke (2010) for a detailed description of the artificial viscosity parameters.