Table A.1
Best-fit model parameters of O vii lines during obs2.
N nthComp a | 0.032 | |
λ I | 21.82 ![]() |
Å |
σ I | < 0.05b | Å |
A I | 10 ![]() |
10-5 ph s-1 cm-2 |
λ R | 21.675 ![]() |
Å |
σ R | < 0.09 | Å |
A R | 13 ± 7 | 10-5 ph s-1 cm-2 |
λ F | 22.10 – | Å |
σ F | 0– | Å |
A F | <1.8 | 10-5 ph s-1 cm-2 |
![]() |
1.01/64 |
Notes. The subscripts I, R, and F refer to the intercombination, resonance, and forbidden lines, respectively. The fit has been performed fixing the line width to zero, while the upper limit was determined in a second iteration with the line width set as a free parameter.
The normalization of the continuum is first recomputed in the fit and then fixed; all the other continuum parameters are fixed to those of the average spectrum measured in Sect. 3.1.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.