Free Access

Table 4

Effective spectroscopic constants determined from state-by-state fits of the rotational transitions measured for the v4 = 2, v4 = 3, v5 = 2 and v5 = 3 states of 12C2HDa.

Parameter Unit v4 = 2 v4 = 3 v5 = 2 v5 = 3

B MHz 29887.55176(34) 29971.53551(53) 29816.92379(54) 29864.91215(61)
Previous value 29969.052(43)c 29861.189(27)c
D kHz 36.3586(26) 37.470(20) 35.0859(42) 35.6706(42)
γ 44 MHz –2.47788(10) –2.512476(79)
δ 44 kHz –0.07435(86) –0.0484(39)
γ 55 MHz –3.70183(17) –3.77613(11)
δ 55 kHz –0.0767(14) –0.0767b
q t MHz 134.29328b 135.53447(47) 107.15528b 108.61081(56)
Previous value 135.529(25)c 108.642(28)c
kHz –1.2082b –1.2653(44) –0.6905b –0.7267(47)
g 44 GHz 65.82005(36) 67.137(12)
g 55 GHz 156.406(11) 158.484(62)
σ fit kHz 5.0 8.0 8.1 10.0
No. of lines 22 24 22 20
J range 1–9 1–8 1–9 1–8

Notes.

(a)

Estimated uncertainties (1σ) are given in parentheses in units of the last figure quoted.

(b)

Fixed in the analysis. See text.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.