Free Access
Table 1
Best fit parameters for the NEI model.
Parameter | EPIC | |
|
||
N H | (1020 cm-2) | 4.16 ± 0.77 |
ne nh V | (1054 cm-3) | 2.40 ± 0.18 |
ne t | (109 cm-3 s) | 3.10 ± 0.07 |
kT | (keV) | 1.35 ± 0.10 |
C | 0.29 ± 0.08 | |
N | 0.57 ± 0.06 | |
O | 0.69 ± 0.04 | |
Ne | 0.12 ± 0.01 | |
Mg | 0.45 ± 0.05 | |
Si | 4.75 ± 0.37 | |
|
||
cstat/d.o.f. | 1603/842 |
Notes.Best fit parameters for the EPIC data. The MOS and pn data of the three observations of the knot were fitted simultaneously. The Anders & Grevesse (1989) solar abundances were used and the errors denote a 1σ uncertainty. Unlisted abundances were fixed at solar.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.