Free Access

Table A.44

Frequencies for KIC 11081729.

Degree Frequency (μHz) 68% credible (μHz) Comment

0 1262.770 Not fitted 0.707
0 1355.960 Not fitted 0.695
0 1447.669 +0.392/−0.392 0.708
0 1536.687 +0.354/−0.354 OK
0 1625.412 +0.594/−0.594 OK
0 1714.308 +0.524/−0.555 OK
0 1802.430 +0.420/−0.420 OK
0 1891.692 +0.589/−0.589 OK
0 1981.503 +0.483/−0.483 OK
0 2072.940 +0.572/−0.538 OK
0 2164.025 +0.620/−0.569 OK
0 2256.372 +0.762/−0.761 OK
0 2346.542 +0.647/−0.647 OK
0 2436.781 +1.178/−1.178 OK
0 2528.775 +1.691/−1.629 OK
0 2621.709 +3.087/−3.084 Not detected
0 2714.649 +4.881/−5.214 Not detected
0 2803.610 Not fitted 0.819

1 1398.486 +0.883/−1.008 0.690
1 1487.919 +0.202/−0.202 OK
1 1577.636 +0.294/−0.294 OK
1 1668.230 +0.454/−0.504 OK
1 1757.240 +0.340/−0.340 OK
1 1846.084 +0.350/−0.350 OK
1 1935.098 +0.524/−0.523 OK
1 2025.779 +0.521/−0.477 OK
1 2116.217 +0.519/−0.519 OK
1 2207.716 +0.602/−0.547 OK
1 2299.972 +0.488/−0.487 OK
1 2391.297 +0.392/−0.392 OK
1 2482.558 +0.984/−0.983 OK
1 2574.025 +1.298/−1.349 Not detected
1 2665.859 +2.201/−2.267 0.868

2 1438.222 +3.104/−2.564 Not detected
2 1528.101 +1.711/−1.139 OK
2 1618.361 +1.012/−1.011 OK
2 1708.687 +0.977/−0.977 OK
2 1798.854 +0.964/−0.856 OK
2 1888.431 +0.702/−1.053 OK
2 1976.764 +1.262/−1.261 OK
2 2066.581 +1.563/−1.451 OK
2 2157.606 +1.915/−1.351 OK
2 2250.855 +1.452/−1.813 OK
2 2342.650 +1.519/−1.771 OK
2 2433.337 +1.223/−1.444 OK
2 2523.461 +2.052/−2.256 OK
2 2613.620 +3.405/−3.522 Not detected
2 2703.825 +5.010/−5.263 Not detected

Notes. The first column is the degree. The second column is the frequency. The third column is the 68%-credible interval quoted when the mode is fitted. The last column provides an indication of the quality of the detection: OK indicates that the mode was correctly detected and fitted; Not detected indicates that the mode was fitted but not detected by the quality assurance test and Not fitted indicates that the mode was detected with a posterior probability provided by the quality assurance test. When an uncertainty and a posterior probability are quoted, it means that the mode is fitted but detected using the quality assurance test with a probability lower than 90%.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.