Free Access

Table A.41

Frequencies for KIC 10909629.

Degree Frequency (μHz) 68% credible (μHz) Comment

0 647.315 +0.443/−0.487 OK
0 696.682 +0.327/−0.327 OK
0 746.694 +0.166/−0.166 OK
0 795.622 +0.260/−0.286 OK
0 843.702 +0.366/−0.342 OK
0 892.383 +0.342/−0.363 OK
0 942.525 +0.379/−0.402 OK
0 992.775 +0.385/−0.385 OK
0 1043.349 +0.522/−0.522 OK
0 1094.804 +0.565/−0.650 OK
0 1144.494 +0.656/−0.630 OK
0 1194.192 +0.629/−0.629 OK
0 1243.034 +0.922/−1.119 Not detected

1 668.481 +0.513/−0.537 OK
1 718.099 +0.402/−0.378 OK
1 767.346 +0.237/−0.260 OK
1 816.423 +0.266/−0.288 OK
1 864.836 +0.244/−0.244 OK
1 914.743 +0.229/−0.206 OK
1 964.098 +0.288/−0.310 OK
1 1014.752 +0.299/−0.320 OK
1 1064.611 +0.453/−0.453 OK
1 1115.679 +0.522/−0.604 OK
1 1165.387 +0.737/−0.704 OK
1 1215.840 +0.774/−0.803 Not detected
1 1266.571 +1.443/−1.488 Not detected

2 645.885 +1.514/−1.511 OK
2 694.741 +0.795/−0.794 OK
2 742.893 +0.980/−0.979 OK
2 791.207 +0.867/−0.722 OK
2 840.425 +0.830/−0.691 OK
2 890.144 +0.601/−0.534 OK
2 940.768 +0.698/−0.698 OK
2 990.597 +0.868/−0.867 OK
2 1040.725 +0.811/−0.736 OK
2 1091.023 +0.912/−0.911 OK
2 1141.073 +1.002/−1.001 OK
2 1190.235 +1.324/−1.393 OK
2 1238.786 +2.185/−2.123 Not detected
2 1337.350 Not fitted 0.704

Notes. The first column is the degree. The second column is the frequency. The third column is the 68%-credible interval quoted when the mode is fitted. The last column provides an indication of the quality of the detection: OK indicates that the mode was correctly detected and fitted; Not detected indicates that the mode was fitted but not detected by the quality assurance test and Not fitted indicates that the mode was detected with a posterior probability provided by the quality assurance test. When an uncertainty and a posterior probability are quoted, it means that the mode is fitted but detected using the quality assurance test with a probability lower than 90%.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.