Free Access

Table A.2

Frequencies for KIC 2837475.

Degree Frequency (μHz) 68% credible (μHz) Comment

0 985.740 +0.169/−0.225 OK
0 1057.562 +0.842/−0.841 OK
0 1130.442 +0.702/−0.654 OK
0 1205.403 +0.547/−0.638 OK
0 1279.772 +0.674/−0.674 OK
0 1355.167 +0.515/−0.566 OK
0 1432.082 +0.514/−0.608 OK
0 1509.488 +0.409/−0.368 OK
0 1585.937 +0.484/−0.537 OK
0 1660.125 +0.631/−0.631 OK
0 1734.503 +0.654/−0.654 OK
0 1810.869 +0.946/−0.946 OK
0 1886.532 +1.081/−1.029 OK
0 1963.679 +1.459/−1.400 OK
0 2041.304 +2.430/−2.246 OK
0 2117.550 Not fitted 0.630
0 2194.480 Not fitted 0.813
0 2265.410 Not fitted 0.807

1 1020.321 +0.258/−0.309 OK
1 1093.727 +0.617/−0.566 OK
1 1167.088 +0.578/−0.525 OK
1 1241.065 +0.532/−0.577 OK
1 1315.382 +0.654/−0.653 OK
1 1390.946 +0.467/−0.467 OK
1 1468.287 +0.518/−0.518 OK
1 1544.878 +0.431/−0.431 OK
1 1620.036 +0.467/−0.513 OK
1 1695.664 +0.432/−0.432 OK
1 1771.638 +0.523/−0.522 OK
1 1845.982 +0.607/−0.560 OK
1 1922.405 +0.686/−0.686 OK
1 2000.119 +0.770/−0.770 OK
1 2077.552 +1.182/−1.128 OK
1 2303.520 Not fitted 0.855

2 977.959 +4.691/−3.024 Not detected
2 1051.458 +3.784/−1.258 OK
2 1125.882 +1.897/−1.624 OK
2 1199.526 +1.111/−1.295 OK
2 1272.976 +1.124/−1.123 OK
2 1347.530 +1.152/−1.151 OK
2 1423.080 +1.222/−1.119 OK
2 1499.386 +1.509/−1.407 OK
2 1575.939 +1.8650/−1.569 OK
2 1652.855 +2.032/−2.029 OK
2 1729.308 +2.131/−2.128 OK
2 1805.913 +1.800/−1.893 OK
2 1882.285 +1.280/−1.377 OK
2 1959.293 +1.425/−1.526 OK
2 2036.156 +2.423/−2.630 OK
2 2265.410 Not fitted 0.807

Notes. The first column is the degree. The second column is the frequency. The third column is the 68%-credible interval quoted when the mode is fitted. The last column provides an indication of the quality of the detection: OK indicates that the mode was correctly detected and fitted; Not detected indicates that the mode was fitted but not detected by the quality assurance test and Not fitted indicates that the mode was detected with a posterior probability provided by the quality assurance test. When an uncertainty and a posterior probability are quoted, it means that the mode is fitted but detected using the quality assurance test with a probability lower than 90%.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.