Table 4
Derived properties of the detected species over the deconvolved sizes of the lines for all sources in the project.
IRAS2A | IRAS4A-NW | IRAS4B | |
|
|||
NCH3OCH3a | 1.2 × 1017b | 6.8 × 1016 | 5.6 × 1016 |
![]() |
2.9 × 1016 | 7.9 × 1015 | 3.9 × 1015 |
N C2H5CNa | <1.4 × 1014 | 1.1 × 1015 | 2.8 × 1014 |
NSO2a | 1.8 × 1016 | 8.2 × 1015 | 1.3 × 1015 |
|
|||
MH2O (M⊙) | 1.8 × 10-6 | 2.7 × 10-7 | 1.5 × 10-8 |
MH2O (M⊕) | 0.61 | 0.09 | 0.006 |
X(=NH2O/NH2) | 4.2 × 10-6 | 1.4 × 10-7 | 7.8 × 10-9 |
Notes.
In cm-2 assuming Tex = 170 K. The typical error is a combination of the assumption of the excitation temperature and the flux calibration uncertainty (~20%). The determined column density varies with Tex in the interval 100–200 K differently for each molecule, see Fig. 8 and the discussion in Sect. 4.5.3.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.