Table 2
Summary of observations and observing conditions.
Object | Filter | DIT × NDITa | Dither | Airmass | Obs. date | ⟨EC⟩ c[%] | ⟨τ0⟩ d [ms] |
positionsb | mean/min/max | mean/min/max | |||||
|
|||||||
HD 97048 | H | 0.35 s × 85 | 10(12) | 1.76–1.68 | 2006-Apr.-08 | 42.3/14.9/56.7 | 5.9/3.7/9.4 |
Ks | 0.35 s × 85 | 8(8) | 1.68–1.66 | 2006-Apr.-08 | 50.2/41.3/55.9 | 5.5/2.7/8.1 | |
NB1.64 | 3.0 s × 20 | 16(16) | 1.66–1.74 | 2006-Apr.-08 | 53.9/46.2/60.4 | 7.3/3.0/9.8 |
Notes.
Detector integration time (DIT) × number of integrations (NDIT), i.e., total integration time per dither position and per retarder plate position;
Number of dither positions used in final analysis and in parenthesis total number of observed dither position. The difference was disregarded because of poor AO correction. At each dither position NDIT exposures were taken at each of the four different retarder plate positions (0.0°, –22.5°, –45.0°, –67.5°);