Relative (percentual) calibration error budget for the HIFI Instrument.

HIFI mixer band
Error source 1 & 2 3 & 4 5 6& 7

Sideband ratio 3–4 4–6 4 5–8
Hot load coupling1  <1  <1  <2  <3
Cold load coupling1  <1  <1  <2  <3
Hot load temp.  <1  <1  <1  <1
Cold load temp.  <1  <1  <1  <1
Planetary model  <5  <5  <5  <5
Beam efficiency  <5  <5  <10  <5
Pointing2  <1  <3  <4  <8
Opt. standing waves 4 4 3 3

Notes. 

(1)

The coupling error in bands 6 & 7 is likely an overestimate and may include standing wave effects.

(2)

This relative intensity error is given for an Absolute Pointing Error (APE) of 2′′ for a single point observation of a point source.