Free Access

Table 7

Fit coefficients for dielectronic recombination rate coefficients (see Eq. (3)).

Target
Iona Level c 1 c 2 c 3 c 4 c 5 c 6 c 7

Se+ 1 5.895(–8) 1.516(–7) 2.154(–6) 4.509(–6) 7.933(–4) 2.944(–3) 2.944(–3)
2b 4.849(–9) 4.750(–8) 1.915(–7) 1.839(–6) 1.633(–4) 2.211(–3) 7.745(–6)
3 2.580(–8) 4.667(–8) 2.042(–6) 2.148(–3) 5.616(–4) ... ...
4 2.086(–8) 2.435(–7) 2.120(–6) 3.332(–7) 3.652(–6) 1.713(–3) 1.929(–4)
5 2.547(–7) 1.297(–7) 4.131(–4) 2.075(–3) 2.433(–6) ... ...
Se2+ 1 4.841(–6) 4.993(–5) 3.566(–5) 9.558(–5) 9.458(–3) 1.988(–5) ...
2 1.830(–6) 5.312(–6) 1.432(–5) 2.280(–5) 5.604(–3) 2.176(–3) ...
3 1.686(–8) 2.146(–7) 5.827(–7) 2.436(–6) 1.391(–4) 6.526(–3) ...
4c 3.875(–8) 1.641(–6) 3.522(–3) 3.732(–3) -3.333(–4) ... ...
5 7.246(–13) 9.784(–9) 3.270(–6) 2.470(–5) 2.923(–4) 1.598(–3) 1.609(–3)
Se3+ 1 1.268(–6) 2.651(–6) 1.386(–5) 1.166(–4) 3.731(–3) 6.768(–3) 6.499(–3)
2 2.286(–6) 3.420(–6) 4.948(–5) 4.206(–4) 1.030(–2) ... ...
Se4+ 1 1.505(–5) 3.440(–5) 2.571(–4) 2.806(–3) 2.952(–2) ... ...
Se5+ 1 1.107(–5) 2.896(–5) 8.937(–5) 6.877(–5) 1.457(–2) 1.213(–2) ...
Se6+ 1 2.771(–6) 3.733(–5) 1.459(–4) 7.999(–4) 5.106(–3) 1.052(–2) ...

E 1 E 2 E 3 E 4 E 5 E 6 E 7

Se+ 1 1.036(3) 1.963(3) 4.529(3) 1.464(4) 1.217(5) 1.754(5) 1.772(5)
2b 8.714(1) 2.241(2) 7.538(2) 1.046(4) 9.325(4) 1.525(5) 1.764(6)
3 9.716(1) 1.663(3) 1.077(4) 1.330(5) 2.180(5) ... ...
4 2.655(2) 3.997(2) 9.086(2) 1.797(3) 3.584(4) 1.336(5) 2.199(5)
5 8.821(2) 2.098(3) 9.386(4) 1.423(5) 8.491(5) ... ...
Se2+ 1 1.289(2) 5.862(2) 1.935(3) 7.117(4) 1.957(5) 1.719(6) ...
2 6.188(1) 3.923(2) 2.220(3) 3.978(4) 1.797(5) 2.263(5) ...
3 4.308(2) 9.211(2) 3.360(3) 1.096(4) 8.181(4) 1.899(5) ...
4c 4.521(3) 1.678(4) 1.429(5) 2.330(5) 5.738(5) ... ...
5 1.158(3) 5.031(3) 1.522(4) 3.687(4) 9.171(4) 1.416(5) 1.657(5)
Se3+ 1 7.565(2) 1.959(3) 6.654(3) 3.054(4) 1.518(5) 2.134(5) 2.156(5)
2 6.470(2) 3.122(3) 1.519(4) 6.767(4) 1.908(5) ... ...
Se4+ 1 5.954(2) 3.483(3) 2.477(4) 1.053(5) 1.886(5) ... ...
Se5+ 1 3.417(2) 2.862(3) 1.556(4) 4.233(4) 1.420(5) 1.941(5) ...
Se6+ 1 2.567(3) 8.368(3) 2.392(4) 1.260(5) 5.466(5) 1.186(6) ...

Notes. Coefficients ci are in cm3 s-1 K3/2, and Ei are in K. The fits are accurate to within 5% over the temperature range (101−107)z2 K, unless otherwise noted. The notation x(y) denotes x × 10y.

(a)

Note that the ion and level numbers correspond to the target ion (i.e., before recombination).

(b)

The fit is accurate to within 6%.

(c)

The rate coefficient for DR onto level 4 of the Se2+ target could not be fit to accuracies as high as other levels and ions, and is not valid below 80 K. The fit is only accurate to within 11% near 2000 and 40 000 K, but to within 2% at all other temperatures.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.