Table 2:

Sensitivity budget for LFI units.

Symbol
Name 30 GHz 44 GHz 70 GHz
$L_{\rm Feed} L_{\rm OMT}$[dB] Feed + OMT insertion loss.................. -0.25 -0.25 -0.25
$T_{\rm FE}$[K] FEM noise temperature............ 8.6 14.1 25.7
$T_{\rm Feed}+T_{\rm OMT}+T_{\rm FE}$[K]  ............................... 10.4 16.2 28.5
$G_{\rm FE}$[dB] FEM gain............... >30 >30 >30
$L_{\rm WG}$[dB] Waveguide insertion loss........... -2.5 -3 -5
$T_{\rm BE}$[K] BEM noise temperature........... 350 350 450
$T_{\rm WB}+T_{\rm BE}$[K]  ............................... 0.3 0.4 0.7
$T_{\rm sys}$[K] System temperature........... 10.7 16.6 29.2


Source LaTeX | All tables | In the text