Table 5:

White noise sensitivities per radiometer in $\mu {\rm K}\cdot {\rm s}^{1/2}$.

From uncalib. noise
  M-0 S-1
70 GHz    
LFI18 468 468
LFI19 546 522
LFI20 574 593
LFI21 424 530
LFI22 454 463
LFI23 502 635
44 GHz    
LFI24 372 447
LFI25 501 492
LFI26 398 392
30 GHz    
LFI27 241 288
LFI28 315 251

From radiom. equation
  M-0 S-1
70 GHz    
LFI18 450 450
LFI19 482 466
LFI20 498 511
LFI21 381 496
LFI22 428 410
LFI23 453 419
44 GHz    
LFI24 404 407
LFI25 451 462
LFI26 455 428
30 GHz    
LFI27 311 320
LFI28 305 268

Notes.  Sensitivity values have been extrapolated at CMB input using the two methods outlined in the text and detailed in Appendix D.


Source LaTeX | All tables | In the text

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.