Sourcea | Transition | Frequencyb | ![]() |
![]() |
Ie
![]() |
Ie
![]() |
Comments |
(MHz) | (MHz) | (mK) | (K km s-1) | (K km s-1) | |||
(1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) |
(20
![]() ![]() |
40,4-30,3 | 83 900.572 | 0.31 | 25 | 10.19(15) | 7.89 | no blend |
50,5-40,4 | 1 04 874.679 | 0.31 | 19 | 7.38(11) | 7.60 | no blend | |
70,7-60,6 | 1 46 820.687 | 0.31 | 29 | 3.59(13) | 3.66 | no blend | |
80,8-70,7 | 1 67 792.311 | 0.31 | 40 | 2.94(17) | 1.94 | weak detection | |
Sgr B2(M) | 40,4-30,3 | 83 900.572 | 0.31 | 8 | 2.13(05) | 1.67 | no blend |
50,5-40,4 | 1 04 874.679 | 0.31 | 10 | 2.67(05) | 2.20 | partial blend with 13CH3CH2CN + U-line? | |
70,7-60,6 | 1 46 820.687 | 0.31 | 18 | 4.50(08) | 2.90 | partial blend with U-line? | |
80,8-70,7 | 1 67 792.311 | 0.31 | 43 | 6.56(17) | 3.65 | partial blend with U-line? | |
Sgr B2(N) | 40,4-30,3 | 83 900.572 | 0.31 | 9 | 4.66(05) | 3.74 | weak blend with CH3CH3CO |
50,5-40,4 | 1 04 874.679 | 0.31 | 10 | 13.98(05) | 5.05 | strong blend with C2H3CN, v11 = 1/v15 = 1 and 13CH3CH2CN | |
70,7-60,6 | 1 46 820.687 | 0.31 | 17 | 12.01(08) | 6.89 | blend with U-lines | |
80,8-70,7 | 1 67 792.311 | 0.31 | 42 | 16.57(18) | 8.66 | blend with H13CCCN, v6=1 and U-line | |
Sgr B2(S) | 70,7-60,6 | 1 46 820.687 | 4.00 | 21 | 5.03(39) | 3.68 | no blend |
80,8-70,7 | 1 67 792.311 | 4.00 | 20 | 0.70(32) | 1.60 | uncertain detection | |
(20
![]() ![]() |
70,7-60,6 | 1 46 820.687 | 4.00 | 29 | 1.76(53) | 1.93 | uncertain detection |
80,8-70,7 | 1 67 792.311 | 4.00 | 24 | 0.03(38) | 1.51 | uncertain detection | |
(-40
![]() ![]() |
70,7-60,6 | 1 46 820.687 | 4.00 | 26 | 4.76(61) | 4.55 | no blend |
80,8-70,7 | 1 67 792.311 | 4.00 | 36 | 5.17(73) | 4.13 | uncertain detection |
Notes.
(a) The J2000
equatorial offsets are given with respect to Sgr B2(M). (b) Laboratory
rest frequencies were taken from (Brünken
et al. 2009a). (c) Channel
width. (d) Measured
rms noise level in
scale. (e) Integrated
intensity in
scale for the observed spectrum (Col. 6) and the model of
cyanic acid (Col. 7). The integration limits are marked in
Figs. 3-5 by
vertical dotted lines. The uncertainty in Col. 6 is given in
parentheses in units of the last digit and is purely statistical.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.