Table 1:

Best-fit parameters for the spectra extracted in region Y (black ellipse in Fig. 2) and region N (i.e. the entire remnant minus region Y).

Parameter
Region Y Region N

kT2 (keV)
$\rm 1.73^{+0.03}_{-0.02}$ $1.53\pm0.02$
EM*2(1020 cm-5) $\rm 2.29^{+0.03}_{-0.6}$ $\rm0.43^{+0.01}_{-0.01}$
${\rm Fe/Fe}_\odot$(**) $\rm 5.8_{-0.2}^{+0.2}$ $4.7\pm 0.3$
${\rm Ni/Ni}_\odot$(**) $\rm 9.7_{-0.7}^{+1.5}$ $9\pm1$
reduced $\chi^{2}$/d. o. f. 1.74/722 1.57/722

reduced $\chi^{2}/$d. o. f.(8.3-12 keV)(***)
6.1/38 2.2/38

Notes. The best-fit model and the fitting procedure are described in Sect. 2. All errors are at the 90% confidence level.
(*) Emission measure per unit area. (**) Abundances derived in CIE, Discrepancies with O09 are due to the CIE model adopted here. (***) Contribution to the $\chi^{2}$ of the 8.3-12 keV spectral bins.