Science with AKARI
Free Access

 

 

Table 3:

Results of the SED fitting, with the parameters defined in the text.

Name
$z_{\rm phot}$ $\delta z_{\rm phot,min}$ $\delta z_{\rm phot,max}$ $\chi^2_\nu$ $N_{\rm D.O.F.}$ Dust Age $\Theta$ $\theta_{\rm view}$ $f_{\rm AGN}$ Notes
LOCK850.001 5.30 1.10 0.46 0.98 8 SMC 50 1.6 35 0.73  
LOCK850.002 3.68 0.34 0.24 4.15 8 LMC 50 1.2 5 0.77 I
LOCK850.003 3.80 0.22 0.20 6.67 8 SMC 50 2.0 0 0.70  
LOCK850.003B 6.56 1.14 0.44 7.15 8 MW 600 2.2 35 0.98 D, C
LOCK850.004 3.76 0.56 2.90 2.77 9 SMC 50 1.6 45 0.08 U
LOCK850.004B 6.54 1.88 0.46 3.54 7 SMC 400 1.8 45 0.42 U
LOCK850.005 6.14 0.60 0.44 10.02 6 SMC 10 1.2 30 0.86 C
LOCK850.006 5.58 1.94 1.41 3.31 8 SMC 70 2.0 42.5 0.20 I
LOCK850.007 2.56 0.60 4.44 0 -3 SMC 50 0.3 10 0.18 I
LOCK850.008 0.22 0.06 6.78 0 -4 SMC 200 0.3 0 0.00 I
LOCK850.009 2.30 0.54 0.70 2.36 6 SMC 400 1.4 32.5 0.56 U, X
LOCK850.009B 1.18 0.46 0.42 2.10 8 MW 600 1.8 0 0.00 U
LOCK850.010B 3.28 0.68 0.52 3.05 5 SMC 50 1.2 90 0.00  
LOCK850.011 1.24 0.32 0.40 2.38 6 MW 500 1.4 15 0.55 X
LOCK850.012 2.26 0.36 1.45 2.03 7 SMC 200 1.6 0 0.37 I
LOCK850.013 0.50 0.26 0.20 2.36 7 SMC 600 2.0 7.5 0.09 X
LOCK850.014 3.06 0.44 0.36 3.72 7 SMC 50 1.8 50 0.01  
LOCK850.015 1.40 0.84 0.40 3.79 8 SMC 400 0.3 27.5 0.11  
LOCK850.015B 1.36 0.18 0.16 2.54 8 SMC 500 0.4 7.5 0.32 D
LOCK850.016 6.58 0.54 0.42 5.22 7 SMC 10 1.2 40 0.44  
LOCK850.017 3.48 1.18 0.34 2.19 5 SMC 100 2.6 7.5 0.50 U
LOCK850.017B 4.20 0.68 1.98 1.72 5 LMC 50 1.4 0 0.65 U
LOCK850.019 3.94 0.24 1.92 1.11 5 SMC 50 2.0 5 0.69 I
LOCK850.021 0.86 0.36 6.14 0.91 6 SMC 500 0.4 17.5 0.15 I
LOCK850.022 3.10 0.90 0.40 2.24 6 MW 600 5.0 0 0.96  
LOCK850.024 2.72 0.70 0.56 2.26 5 SMC 30 1.8 0 0.24  
LOCK850.026 3.48 1.24 0.46 3.23 6 SMC 30 1.6 0 0.74 I
LOCK850.027 1.34 0.18 0.34 2.97 6 MW 600 2.2 0 0.66  
LOCK850.028 3.66 0.58 0.20 1.63 6 SMC 50 2.2 7.5 0.50  
LOCK850.029 4.44 3.38 2.56 0.23 5 SMC 100 1.8 0 0.96 I
LOCK850.030 2.70 1.04 0.53 2.03 6 SMC 50 0.9 50 0.00  
LOCK850.031 1.12 0.50 1.40 2.08 5 SMC 400 0.7 17.5 0.46 X
LOCK850.033 2.78 0.66 0.70 4.75 6 LMC 70 1.2 50 0.00  
LOCK850.034 4.14 0.45 2.02 3.19 6 LMC 50 1.2 90 0.00  
LOCK850.035 5.24 3.26 1.76 0.72 5 SMC 70 2.0 7.5 0.94 I
LOCK850.035B 2.20 0.28 0.78 4.53 5 MW 600 2.2 0 0.66 D
LOCK850.036 0.92 0.54 6.08 0 -4 SMC 200 0.3 0 0.00 I
LOCK850.037B 1.26 0.46 1.00 1.84 5 SMC 300 1.4 22.5 0.38 X
LOCK850.038 1.36 0.30 0.30 1.11 6 MW 300 2.4 20 0.30  
LOCK850.039 0.92 0.74 6.08 0 -4 SMC 200 0.3 0 0.00 I
LOCK850.040 2.24 1.64 0.34 2.02 5 MW 400 1.8 0 0.10 X
LOCK850.041B 2.44 0.94 1.38 3.38 6 LMC 50 2.2 40 0.31  
LOCK850.041 1.60 0.44 0.10 1.61 7 LMC 200 2.4 7.5 0.31  
LOCK850.043 1.38 0.70 0.66 2.03 7 SMC 200 1.6 27.5 0.42 U,X
LOCK850.043B 1.60 0.58 0.40 2.21 7 SMC 100 2.0 0 0.22 U,X
LOCK850.047 3.82 0.20 0.40 1.26 7 LMC 30 3.0 37.5 0.40  
LOCK850.048 4.18 0.86 2.16 1.70 6 SMC 10 1.6 90 0.15  
LOCK850.052 1.42 0.32 0.76 3.77 6 SMC 600 1.0 0 0.73 U
LOCK850.052B 3.64 0.68 0.58 5.73 5 SMC 600 1.4 5 0.97 U
LOCK850.053 2.22 0.40 0.64 2.25 5 MW 600 2.4 0 0.64 X
LOCK850.060 2.46 0.90 2.90 2.27 6 MW 600 1.2 0 0.64  
LOCK850.063 4.98 0.88 0.88 0.42 7 MW 600 2.6 32.5 0.96 I
LOCK850.064 2.10 1.41 1.28 0.98 6 LMC 50 2.2 0 0.27 I
LOCK850.066 3.72 0.00 1.30 0.61 5 SMC 30 0.7 50 0.03  
LOCK850.067 7.00 0.72 0.00 3.33 6 MW 400 3.0 40 0.83  
LOCK850.070 0.62 0.22 0.36 0.61 6 MW 500 1.8 22.5 0.05 X
LOCK850.071 2.24 1.48 0.88 1.91 6 MW 600 1.8 0 0.67 X
LOCK850.073 1.72 0.96 1.88 0.64 6 LMC 100 2.0 50 0.00  
LOCK850.073B 2.26 1.52 1.30 1.17 4 MW 400 2.4 37.5 0.45 D
LOCK850.075 1.28 0.00 2.54 1.30 3 MW 400 2.2 45 0.42  
LOCK850.076 0.48 0.14 0.12 2.22 8 SMC 600 1.0 7.5 0.06 X?
LOCK850.077 3.20 2.62 0.48 2.77 7 SMC 50 1.2 40 0.00 U
LOCK850.077B 3.74 0.32 0.34 5.01 4 LMC 500 1.6 7.5 0.69 U
LOCK850.078 3.38 0.00 2.64 0.57 1 SMC 50 1.4 50 0.02  
LOCK850.079 1.96 0.24 0.22 2.50 7 MW 600 1.2 22.5 0.57  
LOCK850.081 3.18 1.04 0.92 0.83 5 SMC 400 2.0 42.5 0.84 I
LOCK850.083 0.44 0.08 0.06 1.89 7 LMC 600 1.4 0 0.00  
LOCK850.087 2.54 0.82 0.82 0.50 5 SMC 300 1.4 0 0.57  
LOCK850.100 3.66 3.40 2.60 1.85 1 SMC 200 1.6 55 0.08  

Notes. All parameters are dimensionless except the age which is in Myr. In the final column, ``C'' notes possibly contaminated flux at $15~\mu$m, ``D'' notes a depreciated identification, ``I'' insufficient data to determine the AGN bolometric fraction, ``U'' an uncertain identification, and ``X'' a far-infrared excess.


Source LaTeX | All tables | In the text

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.