Issue |
A&A
Volume 495, Number 3, March I 2009
|
|
---|---|---|
Page(s) | 899 - 900 | |
Section | Interstellar and circumstellar matter | |
DOI | https://doi.org/10.1051/0004-6361/20077899e | |
Published online | 09 February 2009 |
Erratum
Results from DROXO
I. The variability of fluorescent Fe 6.4 keV emission in the young star Elias 29. High-energy electrons in the star's accretion tubes?
G. Giardino1 - F. Favata2 - I. Pillitteri3 - E. Flaccomio3 - G. Micela3 - S. Sciortino3
1 - ESA - Research and Science Support Department, ESTEC,
Postbus 299, 2200 AG Noordwijk, The Netherlands
2 -
ESA - Planning and Community Coordination Office, Science Programme, 8-10 rue Mario Nikis, 75738 Paris Cedex 15, France
3 -
INAF - Osservatorio Astronomico di Palermo,
Piazza del Parlamento 1, 90134 Palermo, Italy
A&A, 475, 891-900 (2007), DOI: 10.1051/0004-6361:20077899
Key words: ISM: clouds - ISM: individual objects:

1 Erratum
In the original paper, the equivalent width of the Fe 6.4 keV emission line from Elias 29 was incorrectly calculated, resulting in a systematic underestimate. The error was due to the incorrect use of the task E QWIDTH in X SPEC, the package used for the spectral analysis. By default, the command E QWIDTH computes the equivalent width of a Gaussian component using the level of the continuum within the energy range 0.95 E0 - 1.05 E0, where E0is the position of the Gaussian line. In our case, E0 = 6.4 keV and the continuum level was computed within 6.08 - 6.72 keV, which includes the strong Fe XXV emission line at 6.7 keV. Thus, the use of the X SPEC task in its default mode led us to systematically overestimate the level of the continuum and, by consequence, to underestimate the equivalent width of the Fe 6.4 keV emission line. We provide here the correct equivalent width for the 6.4 keV excess in the spectra of Elias 29 for each time segment. This was also derived with the E QWIDTH command in X SPEC but by limiting the energy range where the continuum level is derived to 0.99 E0 - 1.01 E0, that is, 6.34 - 6.46 keV, thus excluding the strong Fe XXV emission line.
In addition, while repeating the spectral fits, a mistake
in the calculation of the emission measure ()
was discovered. The new
version of Tables 1-4 below give the correct equivalent
width for the 6.4 keV excess and the correct
values.
In the case of the fits to the PN data in the original paper, we
provided the probability that the line could have been spurious, as
derived by Montecarlo simulations (Table 3). The fits to the simulated
data were repeated and the equivalent width of the 6.4 keV emission
computed again using the E QWIDTH command over the correct
range. The new values of the derived probabilities in Table 3 are not
significantly different from the old ones. The new value for the
6.4 keV emission line equivalent width of the spectrum integrated over the
time intervals ``seg2'', ``seg3'', ``seg4'', and ``seg5'' (Sect. 3 of
the paper) is
eV.
Table 1: Best-fit parameters from the fits to the spectra of Elias 29, during 6 different time intervals (PN data only), using an absorbed 1T thermal model.
Table 2: Best-fit parameters from the joint fits to PN, MOS1 and, MOS2 spectra of Elias 29, during 5 different time intervals, using an absorbed 1T thermal model.
Table 3: Best-fit parameters from the fits to the spectra of Elias 29, during 6 different time intervals (PN data only), using an absorbed 1T thermal model with an additional line at 6.4 keV (Fe fluorescent line).
Table 4: Best-fit parameters from joint fits to PN, MOS1, and MOS2 spectra of Elias 29, during 5 different time intervals, using an absorbed 1T thermal model with an additional line at 6.4 keV (Fe fluorescent line).
2 Conclusions
As regrettable as these mistakes are, they do not change the
conclusions of the paper. The error in the calculation of the has no impact on any of the conclusions, since this quantity was only
presented in the tables and was not used elsewhere in the paper. The
equivalent width of the Fe 6.4 keV emission line was discussed at
several points in the paper; however, the mistake made in its
calculation also does not change the conclusions of the paper. Indeed,
as briefly outlined below, the new higher values reinforce some of the
conclusions.
One of the main results of the paper is the observation of the time
variability of the Fe 6.4 keV emission, and this is not affected by the
changes in the values of the line equivalent width; indeed, the newly
calculated probabilities in Table 3 are still fully consistent with
the 6.4 keV emission being absent during the first segment of the
observation. In the original paper we stressed that no fluorescence,
whether from the photosphere or from a circumstellar shell, can result
in the large equivalent widths observed, given a plausible thermal
photoionising continuum. This is even truer given the new higher
values. The higher values are also even more difficult to reconcile
with emission from photoionisation of the material in the
circumstellar disc. The model of George & Fabian (1991) for a centrally
illuminated face-on disc predicts a maximum equivalent width of only
120 eV. In their recent study of fluorescent Fe K emission,
Drake et al. (2008) predicts equivalent width of the order of 150 eV with
the most favourable geometry for the illumination of an infinite flat
disc, for a continuum temperature of 8 keV (which is twice the
temperature derived for Elias 29 continuum emission).
Our discussion of an alternative scenario where fluorescent emission
is due to collisional excitation by a population of non-thermal
electrons is also not affected by the change in the equivalent width
of the K emission since this discussion was based on the
observed line flux (
10-6 photons cm-2 s-1), the
value of which is unchanged.
References
- Drake, J. J., Ercolano, B., & Swartz, D. A. 2008, ApJ, 678, 385 [NASA ADS] [CrossRef] (In the text)
- George, I. M., & Fabian, A. C. 1991, MNRAS, 249, 352 [NASA ADS] (In the text)
All Tables
Table 1: Best-fit parameters from the fits to the spectra of Elias 29, during 6 different time intervals (PN data only), using an absorbed 1T thermal model.
Table 2: Best-fit parameters from the joint fits to PN, MOS1 and, MOS2 spectra of Elias 29, during 5 different time intervals, using an absorbed 1T thermal model.
Table 3: Best-fit parameters from the fits to the spectra of Elias 29, during 6 different time intervals (PN data only), using an absorbed 1T thermal model with an additional line at 6.4 keV (Fe fluorescent line).
Table 4: Best-fit parameters from joint fits to PN, MOS1, and MOS2 spectra of Elias 29, during 5 different time intervals, using an absorbed 1T thermal model with an additional line at 6.4 keV (Fe fluorescent line).
Copyright ESO 2009
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.